-
Isolated Avulsion Fracture of the Lesser Tuberosity of the Humerus: A Case Report
-
Tae Ho Kim, Ki Do Hong, Sung Sik Ha, Jae Chun Sim, Min Chul Sung
-
J Korean Fract Soc 2014;27(1):72-76. Published online January 31, 2014
-
DOI: https://doi.org/10.12671/jkfs.2014.27.1.72
-
-
Abstract
PDF
- Isolated avulsion of the lesser tuberosity of the humerus is a rare injury. The mechanism of injury is the avulsion of the lesser tuberosity from forced contractions of the subscapularis muscle when the arm is forced into an externally rotated position on shoulder abduction. Authors report a case for isolated avulsion of the lesser tuberosity of the humerus which was treated with open reduction and transosseous suture fixation, as well as a view of the literature.
-
Citations
Citations to this article as recorded by 
- What are the patient-reported outcomes, functional limitations, and complications after lesser tuberosity fractures? a systematic review of 172 patients
Reinier W.A. Spek, Bram J.A. Schoolmeesters, Chantal den Haan, Ruurd L. Jaarsma, Job N. Doornberg, Michel P.J. van den Bekerom JSES International.2021; 5(4): 754. CrossRef
-
111
View
-
0
Download
-
1
Crossref
-
Circumferential Wiring Combined with Tension Band Wiring in the Operative Treatment of Patella Fracture
-
Jae Chun Sim, Sung Sik Ha, Ki Do Hong, Tae Ho Kim, Min Chul Sung
-
J Korean Fract Soc 2014;27(1):65-71. Published online January 31, 2014
-
DOI: https://doi.org/10.12671/jkfs.2014.27.1.65
-
-
Abstract
PDF
- PURPOSE
The purpose of this study is to evaluate the radiographic and clinical results of patella fractures using a circumferential wiring combined with tension band wiring. MATERIALS AND METHODS Between January 2005 and June 2012, 22 (male 14, female 8) patients with patella fracture treated with circumferential wiring combined with tension band wiring were analyzed retrospectively. The mean age of patients was 51 years (range, 28 to 72 years). Controlled passive range of motion exercise was started at three weeks from the postoperative day. The patients were evaluated using radiographs, clinical examination, and Levack's scoring system. RESULTS All fractures healed and mean time elapsed for union was 11.5 weeks (range, 10 to 14 weeks). Complete union without displacement and full range of motion was achieved in all cases. Clinical results according to Levack's scoring system were excellent in 20 cases and good in two cases. We found broken wire in one case. In this case, results of clinical evaluation after reoperation were good. CONCLUSION Circumferential wiring combined with tension band wiring is appropriate for patella fractures.
-
Citations
Citations to this article as recorded by 
- Patellar fracture fixation using cannulated screws and Fiber Wire tension band
Elsayed M Bayomy, Mohamed Y Shaheen Egyptian Orthopaedic Journal.2023; 58(1): 15. CrossRef
-
94
View
-
0
Download
-
1
Crossref
-
Surgical Techniques for Percutaneous Reduction by Towel Clips and Percutaneous Intramedullary Fixation with Steinmann Pins for Clavicle Shaft Fractures
-
Ki Do Hong, Jae Chun Sim, Sung Sik Ha, Tae Ho Kim, Jong Hyun Kim, Jong Seong Lee
-
J Korean Fract Soc 2012;25(1):31-37. Published online January 31, 2012
-
DOI: https://doi.org/10.12671/jkfs.2012.25.1.31
-
-
Abstract
PDF
- PURPOSE
To report the clinical results of surgical treatment of clavicle shaft fracture by percutaneous reduction with towel clips and percutaneous intramedullary pin fixation. MATERIALS AND METHODS This study reviewed the results of 80 cases of clavicle shaft fracture treated by percutaneous reduction with towel clips and percutaneous intramedullary pin fixation with Steinmann pins from January 2002 to August 2010, after follow-up for 12 months or more. We evaluated the clinical results, such as union time and complications. RESULTS Bone union was evident in all cases and the mean time for bone union to appear on radiological findings was 10.3 weeks. Using Kang's criteria, 78 of the 80 patients (97.5%) showed good results and there were no severe complications. CONCLUSION Percutaneous reduction with towel clips and the percutaneous intramedullary pin fixation method showed good results for treating clavicle shaft fracture.
-
Citations
Citations to this article as recorded by 
- Additional fixation using a metal plate with bioresorbable screws and wires for robinson type 2B clavicle fracture
Woo Jin shin, Young Woo Chung, Seon Do Kim, Ki-Yong An Clinics in Shoulder and Elbow.2020; 23(4): 205. CrossRef - A Comparison between Minimally Invasive Percutaneous Plate Osteosynthesis and Plate Fixation in the Treatment of Clavicle Midshaft Fracture
Seong-Ho Yoo, Suk-Woong Kang, Bu-Hwan Kim, Moo-Ho Song, Yeong-Joon Kim, Gyu-Taek Park, Chang-Hun Kwack Journal of the Korean Orthopaedic Association.2017; 52(1): 1. CrossRef
-
133
View
-
1
Download
-
2
Crossref
-
Comparison of Operative Management in Distal Radius Fractures Using 3.5 mm Versus 2.4 mm Volar Locking Compression Plates
-
Sung Sik Ha, Tae Ho Kim, Ki Do Hong, Jae Chun Sim, Jong Hyun Kim
-
J Korean Fract Soc 2011;24(2):156-162. Published online April 30, 2011
-
DOI: https://doi.org/10.12671/jkfs.2011.24.2.156
-
-
Abstract
PDF
- PURPOSE
To evaluate clinical and radiological results using 3.5 mm & 2.4 mm volar locking compression plate (LCP) in distal radius fractures. MATERIALS AND METHODS This study reviewed the results of 115 cases of distal radius fractures treated with 3.5 mm volar LCP (73 cases) & 2.4 mm volar LCP (42 cases) from September 2003 to June 2009. The radiographic results were evaluated by radiographic assessment, and the clinical results were evaluated by Knirk and Jupiter's criteria, Modified Mayo wrist scoring system and DASH score. RESULTS Radiological evaluation of the radial length, radial inclination, volar tilt and intraarticular step off were improved both 3.5 mm volar LCP and 2.4 mm volar LCP. Nine cases of arthritis occured in 3.5 mm volar LCP and 7 cases in 2.4 mm volar by using the Knirk and Jupiter's criteria. The mean score evaluated by Modified Mayo was 86.7 in 3.5 mm volar LCP and 84.8 in 2.4 mm volar LCP. DASH score was 11.2 point in 3.5 mm volar LCP, 10.9 point in 2.4 mm volar LCP. All cases showed bone union showing no evidence of malunion, nounion, nor metal failure. CONCLUSION Distal radius fractures treated with 3.5 mm volar LCP and 2.4 mm volar LCP show satisfying radiological and clinical outcome.
-
Citations
Citations to this article as recorded by 
- Treatment of Fractures of the Distal Radius Using Variable-Angle Volar Locking Plate
Jae-Cheon Sim, Sung-Sik Ha, Ki-Do Hong, Tae-Ho Kim, Min-Chul Sung Journal of the Korean Fracture Society.2015; 28(1): 46. CrossRef - Functional Outcomes of Percutaneous K-Wire Fixation for Distal Radius Fractures with or without Osteoporosis
Ki-Chan An, Gyu-Min Kong, Jang-Seok Choi, Hi-Chul Gwak, Joo-Yong Kim, Sung-Yub Jin Journal of the Korean Fracture Society.2013; 26(4): 248. CrossRef
-
81
View
-
0
Download
-
2
Crossref
-
Operative Treatment with Gamma 3 Nail in Femur Intertrochanteric Fracture
-
Ki Do Hong, Jae Chun Sim, Sung Sik Ha, Tae Ho Kim, Yoon Ho Choi, Jong Hyun Kim
-
J Korean Fract Soc 2011;24(1):7-15. Published online January 31, 2011
-
DOI: https://doi.org/10.12671/jkfs.2011.24.1.7
-
-
Abstract
PDF
- PURPOSE
To evaluate clinical and radiological results of surgical treatment of femur intertrochantenric fracture using Gamma 3 nail. MATERIALS AND METHODS With clinical study, 22 patients who were treated surgically by Gamma 3 nail were retrospectively evaluated. By postoperative radiograph and last follow up radiograph we measured Tip-apex distance, Cleveland index, Neck-shaft angle change Lag screw slippage and Union time. And By medical record review, the clinical results were evaluated with the operation time, intraperative estimated blood loss, amount of transfusion, change of mobility and complication. RESULTS The mean change of femur neck shaft angle was 5.18 degrees. The mean lag screw sliding was 5.43 mm. The mean bone union time was 11.8 weeks. From all of these examples shows bone union. The mean operative time was 41 min, blood loss was 161 ml and the transfusion amount was 0.3 pint. In Ceder et al mobility score, it showed 0.2 point decreased and in Jensen social function score, it showed 0.6 point increased. Comparing the results before and after operation, the results were satisfactory. CONCLUSION Using the Gamma 3 nail, the treatment of fermur intertrochanteric fractures showed good results both radiologically and clinically.
-
Citations
Citations to this article as recorded by 
- Changes in Tip-Apex Distance by Position and Film Distance Measured by Picture Archiving and Communication System (PACS)
Kyu Yeol Lee, Sung Soo Kim, Hyeon Jun Kim, Dong Ho Ha, Hyung Min Yoon, Hyun Su Do Hip & Pelvis.2015; 27(1): 36. CrossRef - Results of Asian Type Gamma 3 Nail in Treatment of Trochanteric Fractures
Bing Zhe Huang, Yong Wook Park, Jin Su Park, Kyu Cheol Noh, Soung Yon Kim, Kook Jin Chung, Hong Kyun Kim, Hyong Nyun Kim, Yong Hyun Yoon, Ji Hyo Hwang Journal of the Korean Fracture Society.2014; 27(3): 213. CrossRef - Treatment of Unstable Pertrochanteric Fractures with a Long Intramedullary Nail
Phil Hyun Chung, Suk Kang, Jong Pil Kim, Young Sung Kim, Ho Min Lee, Dae Jung Huh Hip & Pelvis.2013; 25(1): 51. CrossRef - Comparative Study of Intertrochanteric Fracture Treated with the Proximal Femoral Nail Anti-Rotation and the Third Generation of Gamma Nail
Jae-Cheon Sim, Tae-Ho Kim, Ki-Do Hong, Sung-Sik Ha, Jong-Seong Lee Journal of the Korean Fracture Society.2013; 26(1): 37. CrossRef
-
132
View
-
1
Download
-
4
Crossref
-
The Surgical Treatment of Distal Femur Medial Condyle Fracture Using Lateral Anatomical Plate of Opposite Side through Medial Approach
-
Sung Sik Ha, Jae Chun Sim, Ki Do Hong, Jae Young Kim, Kwang Hee Park, Yoon Ho Choi
-
J Korean Fract Soc 2009;22(4):246-251. Published online October 31, 2009
-
DOI: https://doi.org/10.12671/jkfs.2009.22.4.246
-
-
Abstract
PDF
- PURPOSE
To evaluate clinical and radiological results of surgical treatment of distal femur medial condyle fracture using lateral anatomical plate of opposite side through medial approach. MATERIALS AND METHODS: This study reviewed the results of 9 cases of distal femur medial condyle fracture treated with lateral anatomical plate of opposite side through medial approach from December 2005 to June 2007, after a follow up of more than 12 months. There were 2 males and 7 females with a mean age of 63.1 (57~72) years. The clinical results were evaluated using the Schatzker's criteria, and the radiographic results were evaluated using the bone union time. RESULTS: Using the Schatzker's criteria, 7 cases of the 9 patients (78%) showed exellent results. The mean time for bone union was 13.4 (11~15) weeks. There were 3 cases of pain on full weight bearing same as previous operative state by degenerative osteoarthritis. There weren't complications as joint stiffness, infection, varus & rotational deformity, malunion, nonunion, and metal failure. CONCLUSION: Plate fixation using medial approach provides the proper anatomical reduction and stronger fixation, and outcome good results.
-
Citations
Citations to this article as recorded by 
- Medial Plating of Distal Femoral Fracture with Locking Compression Plate-Proximal Lateral Tibia: Cases' Report
Se-Ang Jang, Young-Soo Byun, In-Ho Han, Dongju Shin Journal of the Korean Fracture Society.2016; 29(3): 206. CrossRef
-
132
View
-
1
Download
-
1
Crossref
-
Operative Treatment with ITST in Femur Trochanteric Fracture
-
Ki Do Hong, Jae Chun Sim, Sung Sik Ha, Jae Young Kim, Jung Ho Kang, Kwang Hee Park
-
J Korean Fract Soc 2008;21(4):274-278. Published online October 31, 2008
-
DOI: https://doi.org/10.12671/jkfs.2008.21.4.274
-
-
Abstract
PDF
- PURPOSE
To evaluate the clinical and radiographic results of treatment of trochanteric fracture with ITST (Intertrochanteric/ Subtrochanteric) nail. MATERIALS AND METHODS We reviewed the results of 40 cases of trochanteric fracture treated with ITST from January 2006 to May 2007, which could be followed up for more than 12 months. The cases include 13 males and 27 females, and the mean age is 75.6 years old. The clinical results were evaluated by Ceder mobility assessment, and the radiographic results were evaluated by the change of femoral neck-shaft angle and sliding of lag screw. RESULTS The mean bone union time is 13.5 weeks. Thirty four cases (85%) were recovered to pre-injury state of walking ability. The change of neck-shaft angle was an average of 5.21degrees and the sliding distance of lag screw was an average of 5.78 mm. Complications were occurred in 4 patients (10%). CONCLUSION The ITST nail were seen good results in treatment of trochanteric fracture and has relatively less complications than other internal fixator.
-
Citations
Citations to this article as recorded by 
- Treatment of the Intertrochanteric Femoral Fracture with Proximal Femoral Nail: Nailing Using the Provisional K-wire Fixation
Gu-Hee Jung Journal of the Korean Fracture Society.2011; 24(3): 223. CrossRef
-
120
View
-
0
Download
-
1
Crossref
-
Comparison of Results in Two Operative Treatments for Clavicle Shaft Fractures in Adult: Comparison of Results between Open Reduction and Internal Fixation with the Plate and Percutaneous Reduction by Towel Clip and Intramedullary Fixation with Steinmann Pin
-
Sung Sik Ha, Jae Chun Sim, Ki Do Hong, Jae Young Kim, Jung Ho Kang, Kwang Hee Park
-
J Korean Fract Soc 2007;20(3):233-238. Published online July 31, 2007
-
DOI: https://doi.org/10.12671/jkfs.2007.20.3.233
-
-
Abstract
PDF
- PURPOSE
To evaluate the results between open reduction and internal fixation with the plate and percutaneous reduction by towel clip and intramedullary fixation with Steinmann pin for clavicle shaft fractures in adult. MATERIALS AND METHODS We have studied the results in 33 cases with the plate, 35 cases with the Steinmann pin among total 68 cases of clavicle shaft fracture. The patients were followed up over a period of at least 12 months. The final postoperative outcome was analyzed with the clinical outcomes using Kang's criteria, radiological union time and operation time. RESULTS The clinical outcome that was good or excellent according to the Kang's criteria showed a distribution of 88% in the group using the plate with 29 cases out of total 33 cases, 91% in the group using the Steinmann pin with 32 cases out of total 35 cases. The mean radiological union time was 8.9 weeks in the group using the plate, 9.1 weeks in the group using Steinmann pin. The mean operation time was 72 minutes in the group using the plate, whereas was 18 minutes in the group using Steinmann pin. CONCLUSION In the treatment of adult clavicle shaft fracture, two groups did not show a significant statistical difference in clinical and radiological outcomes. However, the operation time and postoperative functional recovery was significantly shorter and faster in the group using Steinmann pin. Additionally economic and cosmetic aspect was more satisfactory in the group using Steinmann pin.
-
Citations
Citations to this article as recorded by 
- Anatomical Reduction of All Fracture Fragments and Fixation Using Inter-Fragmentary Screw and Plate in Comminuted and Displaced Clavicle Mid-Shaft Fracture
Kyoung Hwan Koh, Min Soo Shon, Seung Won Lee, Jong Ho Kim, Jae Chul Yoo Journal of the Korean Fracture Society.2012; 25(4): 300. CrossRef - Does Interfragmentary Cerclage Wire Fixation in Clavicle Shaft Fracture Interfere the Fracture Healing?
Jae-Kwang Yum, Yong-Woon Shin, Hee-Sung Lee, Jae-Gu Park Journal of the Korean Fracture Society.2011; 24(2): 138. CrossRef
-
133
View
-
1
Download
-
2
Crossref
|