Skip Navigation
Skip to contents

J Musculoskelet Trauma : Journal of Musculoskeletal Trauma

OPEN ACCESS

Articles

Page Path
HOME > J Musculoskelet Trauma > Volume 33(1); 2020 > Article
Original Article Comparison of Percutaneous versus Open Pedicle Screw Fixation for Treating Unstable Thoracolumbar Fractures
Jin Young Han, Ki Youn Kwon
Journal of Musculoskeletal Trauma 2020;33(1):1-8.
DOI: https://doi.org/10.12671/jkfs.2020.33.1.1
Published online: January 31, 2020
Department of Orthopedic Surgery, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju, Korea. 1stspinekky@yonsei.ac.kr

next
  • 145 Views
  • 2 Download
  • 1 Crossref
  • 0 Scopus
next

PURPOSE
This study compared the clinical and radiological results between two groups of patients with percutaneous fixation or conventional fixation after hardware removal.
MATERIALS AND METHODS
The study analyzed 68 patients (43 open fixation and 43 percutaneous screw fixation [PSF] 25) who had undergone fixation for unstable thoracolumbar fractures. The radiologic results were obtained using the lateral radiographs taken before and after the fixation and at the time of hardware removal. The clinical results included the time of operation, blood loss, time to ambulation, duration of the hospital stay and the visual analogue scale.
RESULTS
The percutaneous pedicle screw fixation (PPSF) group showed better results than did the conventional posterior fixation (CPF) group (p<0.05) in regard to the perioperative data such as operation time, blood loss, and duration of the hospital stay. There were no significant differences in wedge angle, local kyphotic angle, and the ΔKyphotic angle on the postoperative plane radiographs between the two groups (p>0.05). There were no significant differences in the wedge angle and local kyphotic angle after implant removal (p>0.05) between the two groups as well. However, there were significant differences in the segmental montion angle (p<0.001), and the PPSF group showed a larger segmental motion angle than did the CPF group (CPF 1.7°±1.2° vs PPSF 5.9°±3.2°, respectively).
CONCLUSION
For the treatment of unstable thoracolumbar fractures, the PPSF technique could achieve better clinical results and an improved segmental motion angle after implant removal within a year than that of the conventional fixation method.


J Korean Fract Soc. 2020 Jan;33(1):1-8. Korean.
Published online Jan 23, 2020.
Copyright © 2020 The Korean Fracture Society. All rights reserved.
Original Article

Comparison of Percutaneous versus Open Pedicle Screw Fixation for Treating Unstable Thoracolumbar Fractures

Jin Young Han, M.D. and Ki Youn Kwon, M.D.
    • Department of Orthopedic Surgery, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju, Korea.
Received December 10, 2019; Revised December 19, 2019; Accepted December 19, 2019.

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

Abstract

Purpose

This study compared the clinical and radiological results between two groups of patients with percutaneous fixation or conventional fixation after hardware removal.

Materials and Methods

The study analyzed 68 patients (43 open fixation and 43 percutaneous screw fixation [PSF] 25) who had undergone fixation for unstable thoracolumbar fractures. The radiologic results were obtained using the lateral radiographs taken before and after the fixation and at the time of hardware removal. The clinical results included the time of operation, blood loss, time to ambulation, duration of the hospital stay and the visual analogue scale.

Results

The percutaneous pedicle screw fixation (PPSF) group showed better results than did the conventional posterior fixation (CPF) group (p<0.05) in regard to the perioperative data such as operation time, blood loss, and duration of the hospital stay. There were no significant differences in wedge angle, local kyphotic angle, and the ΔKyphotic angle on the postoperative plane radiographs between the two groups (p>0.05). There were no significant differences in the wedge angle and local kyphotic angle after implant removal (p>0.05) between the two groups as well. However, there were significant differences in the segmental montion angle (p<0.001), and the PPSF group showed a larger segmental motion angle than did the CPF group (CPF 1.7°±1.2° vs PPSF 5.9°±3.2°, respectively).

Conclusion

For the treatment of unstable thoracolumbar fractures, the PPSF technique could achieve better clinical results and an improved segmental motion angle after implant removal within a year than that of the conventional fixation method.

Keywords
Unstable thoracolumbar vertebral fracture, Conventional posterior fixation, Percutaneous pedicle screw fixation, Implant removal, Segmental motion angle

Figures

Fig. 1
Radiography showing linear and angular measurement. Wedge angle (∠AB°), local kyphotic angle (∠CD°), anterior body height (200×b/(a+c) %), posterior body height (200×e/(d+f) %).

Fig. 2
The segmental motion angle (SMA) was calculated as the difference between the local kyphotic angle on the flexion (FLEX) and extension (EXT) plain radiograph.

Fig. 3
A 64-year-old male with flexion-distraction injury on T12. (A) The preoperative lateral X-ray shows fracture of the T12 body and spinous process. (B) On the magnetic resonance imaging (T2 weighted fat suppression), there was acute compression fracture with a spinous process fracture. (C) The lateral radiograph, taken immediately after surgery, shows anatomical reduction. (D, E) Lateral X-ray of the flexion (D)/extension (E) views that show the range of motion of no fusion segment.

Tables

Table 1
Demographic Note

Table 2
Perioperative Data for Fixation

Table 3
Radiologic Results after Posterior Fixation

Table 4
Radiologic Results 3 Months after Implant Removal

Notes

Financial support:None.

Conflict of interests:None.

References

    1. Carl AL, Tromanhauser SG, Roger DJ. Pedicle screw instrumentation for thoracolumbar burst fractures and fracture-dislocations. Spine (Phila Pa 1976) 1992;17 8 Suppl:S317–S324.
    1. Back SW, Cho HJ, Park YS. Lumbar spine fracture. J Korean Fract Soc 2011;24:277–287.
    1. Akbarnia BA, Crandall DG, Burkus K, Matthews T. Use of long rods and a short arthrodesis for burst fractures of the thoracolumbar spine. A long-term follow-up study. J Bone Joint Surg Am 1994;76:1629–1635.
    1. Alanay A, Acaroglu E, Yazici M, Oznur A, Surat A. Short-segment pedicle instrumentation of thoracolumbar burst fractures: does transpedicular intracorporeal grafting prevent early failure? Spine (Phila Pa 1976) 2001;26:213–217.
    1. Na HY, Choi JC, Choi JW, et al. The efficacy of the treatment of thoracolumbar spine fractures with short-segment posterior instrumentation and fusion. J Korean Fract Soc 2006;19:241–246.
    1. Park Y, Seok SO, Lee SB, Ha JW. Minimally invasive lumbar spinal fusion is more effective than open fusion: a meta-analysis. Yonsei Med J 2018;59:524–538.
    1. Ni WF, Huang YX, Chi YL, et al. Percutaneous pedicle screw fixation for neurologic intact thoracolumbar burst fractures. J Spinal Disord Tech 2010;23:530–537.
    1. Phan K, Rao PJ, Mobbs RJ. Percutaneous versus open pedicle screw fixation for treatment of thoracolumbar fractures: systematic review and meta-analysis of comparative studies. Clin Neurol Neurosurg 2015;135:85–92.
    1. Zhang W, Li H, Zhou Y, et al. Minimally invasive posterior decompression combined with percutaneous pedicle screw fixation for the treatment of thoracolumbar fractures with neurological deficits: a prospective randomized study versus traditional open posterior surgery. Spine (Phila Pa 1976) 2016;41 Suppl 19:B23–B29.
    1. Park HJ, Shim YJ, Kim WK, Cho TY, Kwon SM. Efficiency of implant removal for treatment of the thoraco-lumbar unstable fractures: multi segments fixation·single segment fusion. J Korean Soc Spine Surg 2011;18:103–110.
    1. Ahn JS, Lee JK, Hwang DS, Kim YM, Kim WJ, Byun KH. The change of kyphotic angle and anterior vertebral height after posterior or posterolateral fusion with transpedicular screws for thoracolumbar bursting fractures. J Korean Soc Fract 1999;12:379–387.
    1. Jeon CH, Lee HD, Lee YS, Seo JH, Chung NS. Is it beneficial to remove the pedicle screw instrument after successful posterior fusion of thoracolumbar burst fractures? Spine (Phila Pa 1976) 2015;40:E627–E633.
    1. Kim HS, Kim SW, Ju CI, Wang HS, Lee SM, Kim DM. Implant removal after percutaneous short segment fixation for thoracolumbar burst fracture: does it preserve motion? J Korean Neurosurg Soc 2014;55:73–77.
    1. Chang HG, Kim YW, Jung JC, Kim HS, Lee KB. Preliminary report of temporary posterior instrumentation in stable thoracolumbar burst fractures. J Korean Soc Spine Surg 2002;9:364–373.
    1. Lan T, Chen Y, Hu SY, Li AL, Yang XJ. Is fusion superior to non-fusion for the treatment of thoracolumbar burst fracture? A systematic review and meta-analysis. J Orthop Sci 2017;22:828–833.
    1. Oh HS, Seo HY. Percutaneous pedicle screw fixation in thoracolumbar fractures: comparison of results according to implant removal time. Clin Orthop Surg 2019;11:291–296.
    1. Lee JK, Jang JW, Kim TW, Kim TS, Kim SH, Moon SJ. Percutaneous short-segment pedicle screw placement without fusion in the treatment of thoracolumbar burst fractures: is it effective?: comparative study with open short-segment pedicle screw fixation with posterolateral fusion. Acta Neurochir (Wien) 2013;155:2305–2312.
      discussion 2312.
    1. Vanek P, Bradac O, Konopkova R, de Lacy P, Lacman J, Benes V. Treatment of thoracolumbar trauma by short-segment percutaneous transpedicular screw instrumentation: prospective comparative study with a minimum 2-year follow-up. J Neurosurg Spine 2014;20:150–156.
    1. Wang HW, Li CQ, Zhou Y, Zhang ZF, Wang J, Chu TW. Percutaneous pedicle screw fixation through the pedicle of fractured vertebra in the treatment of type A thoracolumbar fractures using Sextant system: an analysis of 38 cases. Chin J Traumatol 2010;13:137–145.
  • PubReader PubReader
  • Cite
    CITE
    export Copy Download
    Close
    Download Citation
    Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

    Format:
    • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
    • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
    Include:
    • Citation for the content below
    Comparison of Percutaneous versus Open Pedicle Screw Fixation for Treating Unstable Thoracolumbar Fractures
    J Korean Fract Soc. 2020;33(1):1-8.   Published online January 31, 2020
    Close

J Musculoskelet Trauma : Journal of Musculoskeletal Trauma
Close layer
TOP