PURPOSE We investigate the outcomes of treatment of patients with severe comminuted distal radius fractures with volar plate fixation using a pronator-preserving approach. MATERIALS AND METHODS Fourteen patients with severe comminution of the distal radius fractures for whom anatomical reduction of the fractures was deemed difficult to achieve with traditional approaches were enrolled. The gender ratio was 8 males to 6 females, and the average age of the patients was 64.9 years. According to the AO/OTA classification of fractures, 2 patients had 23-A3 fractures, 7 patients had 23-C2, and 5 patients had 23-C3. Radial length, radial inclination, and volar tilt were measured for radiologic evaluation. Modified Mayo wrist score (MMWS) was used for clinical outcome. RESULTS Bony union was achieved in all 14 patients without signs of complications. The average time-to-union was 4.3 months (3-6 months). The radiological findings at the final follow-up were as follows: the average radial inclination was 20.5degrees; the average volar tilt, 7.57degrees; and the average radial length, 11.8 mm. At the final follow-up, the results of the MMWS were 'Fair' in 1 patient, 'Good' in 4, and 'Excellent' in 9. CONCLUSION We propose that a pronator-preserving approach is an effective treatment for severe comminuted distal radius fracture.
Citations
Citations to this article as recorded by
Use of Miniplate for Severe Comminuted Metadiaphyseal Fractures of the Distal Radius Jong-Ryoon Baek, Yong-Cheol Yoon, Seung Hyun Baek Journal of the Korean Fracture Society.2019; 32(4): 204. CrossRef
PURPOSE The purpose of this article is to show the efficacy of a biodegradable plate for treating lateral malleolar fractures in the ankle joint. MATERIALS AND METHODS The 20 patients who underwent an open reduction and internal fixation for lateral malleolar fractures in the ankle joint from February, 2006 to February, 2007 in our hospital were enrolled into the study. The average age of the patients was 49.7 years and the average follow-up period was 5.6 months. The cases were analyzed by radiological bone union time and clinical results according to the criteria of Meyer et al. RESULTS Average radiological bone union time was 10.5 weeks. The clinical result was excellent in 19 cases (95%), good in 1 case (5%). There was one case of minimal displacement less than 1 mm, associated with anterior distal tibio-fibular ligament avulsion fracture. CONCLUSION For proper patients, a biodegradable plate is an effecttive alternative implant for stabilizing lateral malleolar fractures in the ankle joint, because there is no requirement for subsequent removal and slow resorption in vivo.
Citations
Citations to this article as recorded by
Delayed Foreign-body Reaction of Ankle Fracture Treated with a Biodegradable Plate and Screws - A Case Report - Chul-Hyun Park, Dae-Hyun Song, Jae Ho Cho Journal of the Korean Fracture Society.2012; 25(2): 142. CrossRef