Skip Navigation
Skip to contents

J Musculoskelet Trauma : Journal of Musculoskeletal Trauma

OPEN ACCESS

Search

Page Path
HOME > Search
1 "Polyaxial locking plate"
Filter
Filter
Article category
Keywords
Publication year
Authors
Original Article
Treatment of Distal Femoral Fractures Using Polyaxial Locking Plate
Sang Eun Park, Hyun Taek Kang, Young Yul Kim, Jae Jung Jeong, Jung U Lee, Weon Yoo Kim
J Korean Fract Soc 2011;24(4):321-327.   Published online October 31, 2011
DOI: https://doi.org/10.12671/jkfs.2011.24.4.321
AbstractAbstract PDF
PURPOSE
To report the clinical outcome of polyaxial locking plate (Noncontact bridging (NCB) plate (Zimmer, Warsaw, Indiana)) for the treatment of distal femur fracture with minimal invasive percutaneous periosteal osteosynthsis (MIPPO) technique.
MATERIALS AND METHODS
Between February 2008 to April 2010, twenty six patients (11 men, 15 women), twenty eight cases diagnosed as distal femoral fractures are enrolled in this retrospective study. The mean age of the patients was 63 years (34 to 85) and the mean follow-up was 20.3 months (12 to 32). According to the AO/ASIF classification, 15 fractures were type A, 1 type B and 9 type C. And there were 3 periprsthetic fractures around knee. The analysis of the clinical and radiologic outcome were performed by Sanders functional evaluation scale and radiologic follow up after operation, respectively.
RESULTS
Among 28 cases, 25 cases united without additional operation. According to Sanders functional evaluation scale, there were 11 excellent, 9 good, 4 fair, 2 poor. As complications, there were 1 knee stiffness, 1 delayed union, 1 implant failure with refracture, 1 implant loosening. Three patients except one knee stiffness, underwent a second LISS plating using NCB plate and and bone grafting, resulting in a satisfactory final outcome.
CONCLUSION
Internal fixation using polyaxial locking plate with MIPO technique may be one of the most effective methods for the treatment of distal femoral fractures.

Citations

Citations to this article as recorded by  
  • Usefulness of Reduction and Internal Fixation Using a 2.4 mm Hand Plating System in Type AO 33-A3 Distal Femur Fracture: Technical Note
    Bong-Ju Lee, Ja-Yeong Yoon, Seungha Woo
    Journal of the Korean Fracture Society.2023; 36(1): 25.     CrossRef
  • Incidence of nonunion after surgery of distal femoral fractures using contemporary fixation device: a meta‐analysis
    Byung-Ho Yoon, In Keun Park, Youngwoo Kim, Hyoung-Keun Oh, Suk Kyu Choo, Yerl-Bo Sung
    Archives of Orthopaedic and Trauma Surgery.2021; 141(2): 225.     CrossRef
  • 154 View
  • 0 Download
  • 2 Crossref
Close layer

J Musculoskelet Trauma : Journal of Musculoskeletal Trauma
Close layer
TOP