Skip Navigation
Skip to contents

J Musculoskelet Trauma : Journal of Musculoskeletal Trauma

OPEN ACCESS

Search

Page Path
HOME > Search
3 "Percutaneous wiring"
Filter
Filter
Article category
Keywords
Publication year
Authors
Original Articles
Comparison of the Treatment Results between Reduction with Percutaneous Wiring and Reduction without Percutaneous Wiring in Reverse Oblique Trochanteric Fractures (AO Classification 31-A3.3)
Jae Woo Park, Oog Jin Shon, Seung Wan Lim
J Korean Fract Soc 2017;30(4):192-197.   Published online October 31, 2017
DOI: https://doi.org/10.12671/jkfs.2017.30.4.192
AbstractAbstract PDF
PURPOSE
The aim of this study was to investigate the utility of percutaneous wiring in the reduction of reverse oblique trochanteric fractures (AO classification 31-A3.3) by analyzing the treatment results with or without the use of percutaneous wiring.
MATERIALS AND METHODS
Thirty-five cases from January 2008 to August 2014 that could be followed-up for at least one year were selected among patients with unstable trochanteric fractures who underwent either internal fixation or open reduction. Seventeen patients underwent surgery with percutaneous wire fixation but another 18 patients underwent surgery without it. All patients received a closed reduction and internal fixation with an intramedullary nail. The factors evaluated were as follows: the length of operation, loss of blood, length of in-hospital stay, lower limb function scale, return to preinjury daily life, change in femur neck shaft angle, postoperative gap of the fracture site, time taken for bone attachment, quality of post-operative reduction, and complications.
RESULTS
No significant difference in the mean operative time, loss of blood, length of in hospital stay, lower limb function scale, return to pre-injury daily life, change in femur neck shaft angle, postoperative gap of the fracture site, and quality of postoperative reduction was observed between the two groups. A significant difference was noted in the time taken for bone attachment (p=0.032). Bone attachment took 13.3 weeks (9–17 weeks) on average when fixed with percutaneous wiring and no patient was found to have any complications. When treated without percutaneous wiring, however, bone attachment took 17.8 weeks (12.5–28.0 weeks) on average and three cases resulted in delayed union.
CONCLUSION
Percutaneous wiring is a recommended treatment option for patients with an unstable trochanteric fracture.
  • 73 View
  • 0 Download
Close layer
Efficacy of Percutaneous Cerclage Wiring in Intramedullary Nailing of Subtrochanteric Femur Fracture: Technical Note
Ki Chul Park, Hee Soo Kim
J Korean Fract Soc 2013;26(3):212-216.   Published online July 31, 2013
DOI: https://doi.org/10.12671/jkfs.2013.26.3.212
AbstractAbstract PDF
The subtrochanteric fractures of femur have high rates of delayed union or nonunion due to less-dense cancellous bone, insufficient cortical blood flow and high stress concentration. Anatomical reduction and rigid internal fixation are important in this region; however, an open reduction might damage the biological environment at the fracture site as well as increase the risk of nonunion. We present our experience with nine cases of subtrochanteric femur fractures surgically fixated with intramedullary nailing after percutaneous cerclage wiring through minimal incision.

Citations

Citations to this article as recorded by  
  • The stabilising effect by a novel cable cerclage configuration in long cephalomedullary nailing of subtrochanteric fractures with a posteromedial wedge
    Pavel Mukherjee, Jan Egil Brattgjerd, Sanyalak Niratisairak, Jan Rune Nilssen, Knut Strømsøe, Harald Steen
    Clinical Biomechanics.2019; 68: 1.     CrossRef
  • Factors Affecting Time to Bony Union of Femoral Subtrochanteric Fractures Treated with Intramedullary Devices
    Jung-Yoon Choi, Yerl-Bo Sung, Jin-Hee Yoo, Sung-Jae Chung
    Hip & Pelvis.2014; 26(2): 107.     CrossRef
  • 101 View
  • 2 Download
  • 2 Crossref
Close layer
Anatomically Percutaneous Wiring Reduction in Minimally Invasive Plate Osteosynthesis for Distal Tibial Fractures
Young Mo Kim, Chan Kang, Deuk Soo Hwang, Yong Bum Joo, Woo Yong Lee, Jung Mo Hwang
J Korean Fract Soc 2011;24(3):230-236.   Published online July 31, 2011
DOI: https://doi.org/10.12671/jkfs.2011.24.3.230
AbstractAbstract PDF
PURPOSE
To report the method of anatomical reduction and its maintenance by percutaneous wiring reduction in minimally invasive plate osteosynthesis for distal tibial fractures.
MATERIALS AND METHODS
17 cases that were diagnosed oblique, spiral or transverse fracture of distal tibia from August 2007 to February 2010 and were able to anatomically reduce by the method of percutanous wiring reduction in minimally invasive plate osteosynthesis were included in this study. Mean age was 50, and mean follow up period was 18 months. We investigated the period until bone union was achieved, degree of angulation angle, and complications. For postoperative evaluation, Olerud and Molander ankle score and VAS pain score in daily living were checked.
RESULTS
The mean varus/valgus angulation after bone union on AP radiograph was 0.9 degrees and the mean anterior/posterior angulation on lateral radiograph was 2.0 degrees The mean Olerud and Molander ankle score was 89.4, and mean pain score due to walk adjacent to metal plate was 0 points.
CONCLUSION
By the method of percutaneous wiring reduction in distal tibial fracture, anatomical reduction is easily acquired, and only by wire itself, reduction could be maintained, so that without additional manual reduction, plate could be easily fixed.
  • 98 View
  • 0 Download
Close layer

J Musculoskelet Trauma : Journal of Musculoskeletal Trauma
Close layer
TOP