Skip Navigation
Skip to contents

J Musculoskelet Trauma : Journal of Musculoskeletal Trauma

OPEN ACCESS

Search

Page Path
HOME > Search
1 "Nail breakage"
Filter
Filter
Article category
Keywords
Publication year
Authors
Original Article
Nail Breakage after Femoral Interlocking Intramedullary Nailing
Suk Kang, Phil Hyun Chung, Dong Ju Chae, Jong Pil Kim, Joon Han Kim, Sung Pock Park, Jae Sang Park
J Korean Soc Fract 2002;15(3):363-370.   Published online July 31, 2002
DOI: https://doi.org/10.12671/jksf.2002.15.3.363
AbstractAbstract PDF
PURPOSE
We analyze the clinical causes and precautions of nail breakage followed by femoral intramedullary nailing MATERIALS AND METHODS: We reviewed 12 cases of nail breakage followed by the femoral intramedullary nailing from Jan. 1993 to Feb. 2001 and for each cases, we analyzed used nail diameter, patient weight and used nail, time to nail breakage and configuration of non-union. We classified fracture site at the time of trauma as proximal 1/3, middle 1/3, distal 1/3, and evaluated gap of fracture site, displacement of fragment after surgery, location and treatment of broken nail on each part, and analyzed the causes of nail breakage RESULTS: The average time of nail breakage was 8.1 months and distal 1/3 fracture were major as 6 cases. Those were mainly comminuted fracture of Winquist-Hansen type II. After surgery, gap of fracture site and displacement of fragment were mostly observed in middle 1/3 fracture and, in the part of middle 1/3, the site of nail breakage took place in fracture site. Especially in the distal 1/3 fracture, nail breakage happened usually in distal first locking screw hole. The causes of nail breakage were inadequately small diameter of nail inserted into the isthmic portion of medullary canal in proximal fracture, inaccurate reduction of fracture site in middle fracture, and the use of short length of nail and its mechanical damage caused by inaccurate insertion of distal locking screw in distal fracture.
CONCLUSION
To prevent nail breakage while femoral intramedullary nailing, in proximal fracture, adequate diameter of nail has to be inserted into the isthmic portion of medullary canal. In middle fracture, the accurate reduction of fracture site will be necessary, and the case of distal fracture, enough length of nail has to be used and especially it is important not to cause mechanical injury with the accurate insertion of distal locking screw in nail

Citations

Citations to this article as recorded by  
  • Comparison of our self-designed rotary self-locking intramedullary nail and interlocking intramedullary nail in the treatment of long bone fractures
    Bailian Liu, Ying Xiong, Hong Deng, Shao Gu, Fu Jia, Qunhui Li, Daxing Wang, Xuewen Gan, Wei Liu
    Journal of Orthopaedic Surgery and Research.2014;[Epub]     CrossRef
  • Limited Open Reduction and Intramedullary Nailing of Proximal Femoral Shaft Fracture
    Sang Ho Ha, Jun Young Lee, Sang Hong Lee, Sung Hwan Jo, Jae Cheul Yu
    Journal of the Korean Fracture Society.2009; 22(4): 225.     CrossRef
  • 146 View