PURPOSE To evaluate the cause and surgical outcome of extensor pollicis longus rupture after distal radius fractures. MATERIALS AND METHODS Nineteen cases in which the patients underwent surgical treatment for rupture of the extensor pollicis longus after distal radius fractures were followed for more than one year. Among the nineteen cases, fourteen extensor pollicis longus ruptures occurred after conservative treatment, four occurred after closed reduction with K-wire fixation, and one occurred after open reduction and internal fixation with a plate. All cases were treated by extensor indicis proprius transfer. RESULTS Extensor pollicis longus ruptures were caused by K-wire irritation in two, by a protruding screw tip in one, and by a callus in one. In the conservative treatment group, tendon ruptures were diagnosed at an average of 3.1 months (0.7~17). Tendon ruptures were detected in the surgical treatment group at an average of 12.8 months (1~48). All the patients showed favorable recovery of the extension capability of the thumb at the final follow-up. CONCLUSION The main cause of extensor pollicis longus rupture after distal radius fracture was ischemic damage. Therefore, during the surgery, the length and direction of screws and K-wires should be fixed carefully to avoid such damage. Distal radius fracture also requires careful observation of the extensor pollicis longus during follow-up. Furthermore, extensor indicis proprius transfer is considered to be an effective method for extensor pollicis longus rupture.
Citations
Citations to this article as recorded by
Radiologic Analysis of Distal Radius Fracture Accompanying Spontaneous Extensor Pollicis Longus Rupture Jun-Ku Lee, In-Tae Hong, Young-Woo Kwon, Gyu-Chol Jang, Soo-Hong Han Journal of the Korean Fracture Society.2017; 30(2): 63. CrossRef
Assessment of penetration of dorsal screws after fixation of the distal radius using ultrasound: cadaveric study D Williams, J Singh, N Heidari, M Ahmad, A Noorani, L Di Mascio The Annals of The Royal College of Surgeons of England.2016; 98(2): 138. CrossRef
Rupture of the Extensor Pollicis Longus Tendon at the Proximal Screw of Volar Plate Fixation for Distal Radius Fracture - A Case Report - Dong-Ju Shin, Seung-Oh Nam, Hun-Sik Cho Journal of the Korean Fracture Society.2013; 26(4): 338. CrossRef
PURPOSE To evaluate the results of Acutrak-screw fixation without bone-graft for the treatment of stable scaphoid nonunion and to assess its prognostic factors. MATERIALS AND METHODS Fifteen patients who underwent internal fixation using Acutrak-screw without bone graft for stable scaphoid nonunion were studied. Standard radiographs and CT were analyzed for degenerative changes (presence of cystic change and periscaphoid osteoarthritis), the nonunion site using fragment ratio and union. Clinically, patients age and the interval to surgery were evaluated. RESULTS Mean follow-up duration was 31 months and 11 of 15 (73.3 percentages) cases healed at mean time of 12.8 weeks. Fragment ratio of nonunion site was 37.2 percentages in nonunion group and 54.2 percentages in union group (p=0.016). Presence of cystic change and periscaphoid osteoarthritis showed no singnificant statistical difference in both groups. Younger age lower than 20 years was closely related with bone union (p=0.001). But there were little correlation between bone union and interval to surgery. CONCLUSION Internal fixation without bone graft showed 73.3 percentages of overall union rate in the treatment of stable scaphoid nonunion. And young patients who have distally located stable scaphoid nonunion can be successfully treated with internal fixation without bone graft.
PURPOSE To evaluate clinical and radiographic results of open reduction and internal fixation with plate in AO type C3 distal radius fracture. MATERIALS AND METHODS We treated 18 fractures and the mean follow up was 16 months. The average age was 47.1 years old, 12 male and 6 female were included. There were 9 C3.1 fracture, 5 C3.2 and 4 C3.3. Green & O'Brien's modified clinical scoring system and Demerit Point system were applied to evaluate clinical results, for radiographic evaluation, radial length, radial inclination, volar tilt, and Sarmiento's Criteria for Anatomic results were assessed. RESULTS Clinical results were 5 of excellent, 7 of good, and 6 of fair by Green & O'Brien's score and were 5 of excellent, 6 of good, and 7 of fair by Demerit point. There was no significant difference of radiographic results between immediate postoperation and last follow-up, and Sarmiento's Criteria showed 8 excellent, 4 good, and 6 fair. CONCLUSION The open reduction and internal fixation with plate in AO type C3 distal radius is considered as a good treatment method that particularly benefits from fracture stable fixation without fixation loss and early rehabilitation.
Traumatic anterior dislocation of the hip is an uncommon injury, accounting for less than 10% of all reported cases of traumatic hip dislocation. Especially, there are no known report in our country so far. We are reporting a case of a 81 year old man who sustained bilateral anterior hip dislocation after pedestrian traffic accident, and treated by closed reduction and skeletal traction at our institute.
PURPOSE To evaluate the amount and related factors of reduction loss in distal radius fracture after treatment by Kapandji technique. MATERIALS AND METHODS From September 2004 to May 2006, 44 cases (43 patients) of distal radius fractures were treated by Kapandji technique. Fracture were classified with AO classification and volar tilt, radial inclination, and radial length were measured in preoperative, immediate, postoperative radiographs. Also the amount and related risk factors of reduction loss were analyzed. In addition, the radiological results at last follow up were evaluated using modified Lidstrom scoring system. RESULTS There was significantly more reduction loss of volar tilt in the patients with AO type C comparing with other fracture types, but the patients who were treated using three k-wire fixations including intrafocal K-wires showed significantly more reduction loss of volar tilt also. Overall radiological results at last follow up showed that excellent was 50% in cases with dorsal comminution, but, the other cases 90%. In addition, excellent was 70% in type A cases, but, in type C 44%. CONCLUSION Kapandji technique percutaneous pinning is the one of effective treatment options for distal radius fracture. But, type of fracture, total number of K-wires, and presence of dorsal cortical comminution showed the significant relation with postoperative reduction loss of volar tilt and overall radiological results at last follow up.
Citations
Citations to this article as recorded by
Treatment of Fractures of the Distal Radius Using Variable-Angle Volar Locking Plate Jae-Cheon Sim, Sung-Sik Ha, Ki-Do Hong, Tae-Ho Kim, Min-Chul Sung Journal of the Korean Fracture Society.2015; 28(1): 46. CrossRef
Comparative Analysis of the Results of Fixed-angle versus Variable-angle Volar Locking Plate for Distal Radius Fracture Fixation Seung-Do Cha, Jai-Hyung Park, Hyung-Soo Kim, Soo-Tae Chung, Jeong-Hyun Yoo, Joo-Hak Kim, Jung-Hwan Park Journal of the Korean Fracture Society.2012; 25(3): 197. CrossRef
Results of the Kapandji Procedure in the AO Type C Distal Radius Fracture in Patients over Age 60 Chul Hong Kim, Sung Soo Kim, Myung Jin Lee, Hyeon Jun Kim, Bo Kun Kim, Young Hoon Lim Journal of the Korean Fracture Society.2012; 25(3): 191. CrossRef
PURPOSE To evaluate the adequate surgical methods and postoperative rehabilitation by analyzing the outcome of surgical treatment for isolated greater tuberosity fracture of proximal humerus. MATERIALS AND METHODS Ten patients who allowed at least 1 year follow up after the surgical treatment of isolated greater tuberosity fractures were evaluated. Their mean age was 52.3 years (range, 28~67) and mean follow up duration was 23.8 months (range, 12~36). We choosed the different approaches and fixation methods according to size, location and presence of comminution of the fragment, and combined injury. The rehabilitation programs were indivisualized and we evaluated the clinical outcomes using UCLA and Constant scoring system. RESULTS According to the UCLA scoring system, 5 cases were excellent, 3 cases were satisfactory, and 2 cases were unsatisfactory. By the Constant scoring system, 8 cases were excellent and 2 cases were good. The average bony union time was 7.6 weeks (range, 6~8) except the 2 cases of revision surgery. Two cases were operated using cannulated screws alone, 3 cases using only nonabsorbable sutures and 5 cases using cannulated screws and nonabsorbable sutures. One out of two revision cases was developed from the negligence of preoperative shoulder anterior dislocation with rupture of subscapularis, and the other was caused by improper immobilization of the fracture site postoperatively. CONCLUSION Not only the adequate surgical approaches and the fixation methods according to the size and comminution of fragment, but also the identification of combined injuries were very important in the surgical treatment for the isolated greater tuberosity fracture. And we considered that the adequate postoperative rehabilitation and proper protection based on the intraoperative fixation stability play an important role for the better clinical and radiological outcomes.
Citations
Citations to this article as recorded by
Clinical Features and Characteristics of Greater Tuberosity Fractures with or without Shoulder Dislocation Dong-Wan Kim, Young-Jae Lim, Ki-Cheor Bae, Beom-Soo Kim, Yong-Ho Lee, Chul-Hyun Cho Journal of the Korean Fracture Society.2018; 31(4): 139. CrossRef
The Surgical Outcomes of Isolated Greater Tuberosity Fractures of the Proximal Humerus Fixed with the Spring Plate Dong-Ju Shin, Young-Soo Byun, Se-Ang Chang, Hee-Min Yun, Ho-Won Park, Jae-Young Park Journal of the Korean Fracture Society.2009; 22(3): 159. CrossRef
PURPOSE The purpose of this study was to determine the results of internal fixation with locking plate system for the unstable proximal humerus fracture. MATERIALS AND METHODS Sixteen cases of unstable proximal humerus fracture were treated using locking plate system between September 2004 and June 2005. Average age of the patients was 55.6 years (range, 22 to 78), male was four patients, female was twelve. The clinical outcomes were evaluated by using Neer's evaluation criteria and Constant socring system. We analyzed the radiological results by bony union time and Paavolainen method. All data was analyzed statistically. RESULTS According to Neer's evaluation ciriteria, eleven cases (69%) showed excellent or satisfactory results and according to Constant scoring system, twelve cases (75%) showed excellent or good result. Twelve cases (75%) showed good results by Paavolainen method. In all cases, bony union was obtained in average 12.8 weeks after operation. There were two complications; one screw irritation and one screw loosing. CONCLUSION The patients treated using locking proximal humerus plate could exercise earlier due to good initial stability. And the clinical and radiological results were relatively good. The treatment of unstable proximal humerus fracture with locking plate system was considered as a good method.
Citations
Citations to this article as recorded by
Open Intramedullary Nail with Tension Band Sutures & Lock Sutures on Proximal Humeral Three-part Fracture Jin-Oh Park, Jin-Young Park, Sung-Tae Lee, Hong-Keun Park Journal of the Korean Fracture Society.2007; 20(1): 45. CrossRef
PURPOSE To evaluate the clinical results of this modified anatomical Y-plate in treatment of distal humerus fracture and factors that affect the results. MATERIALS AND METHODS From April 1991 to January 2002, 40 cases (16 male, 24 female) of distal humeral fractures were treated using a modified anatomical Y plate. The patient's age, gender, pain, range of motion, instability, function, bone union, and complication were recorded. RESULTS At the operation, the mean age of patients is 49.5 years (12~74 years) and mean follow up period is 18 months (13~82 months). In the range of motion, mean flexion is 122.1 degrees (75~140 degrees) and mean flexion contracture is 11.4 degrees (0~30 degrees). Results by Morrey's functional evaluation include 15 excellent, 23 good and 2 fair cases. There are 2 excellent and 5 good cases in patients of supracondylar fracture which didn't involve the articular surface (A2, A3 type of AO classification), and 13 excellent, 18 good and 2 fair cases in patients of intracondylar fracture which involve the articular surface (B2, C1, C2, C3 type). But there is no statistical significance in results between two groups. There are 3 excellent, 3 good cases in 6 open fracture and 2 excellent, 6 good and 1 fair case in 9 patients with multiple trauma. The patient's age, gender, open fracture, multiple trauma, and intraarticular fracture did not affect the results. CONCLUSION Satisfactory results can be obtained if the modified anatomical Y-plate is used to treat a distal humerus fracture, regardless of many factors affecting the results.
Citations
Citations to this article as recorded by
Comparative study of a Y- anatomical and innovative locking plate versus double plate for supracondylar humeral fracture Hugo Barret, Romain Ceccarelli, Paul Vial D’Allais, Matthias Winter, Michel Chammas, Bertrand Coulet, Cyril Lazerges Orthopaedics & Traumatology: Surgery & Research.2023; 109(5): 103380. CrossRef
Étude comparative d’une plaque verrouillée anatomique et innovante en Y par rapport à 2 plaques à 90 degrés pour la prise en charge des fractures supra condyliennes de l’humérus Hugo Barret, Romain Ceccarelli, Paul Vial d’Allais, Matthias Winter, Michel Chammas, Bertrand Coulet, Cyril Lazerges Revue de Chirurgie Orthopédique et Traumatologique.2023; 109(5): 648. CrossRef
Double Parallel Plates Fixation for Distal Humerus Fractures Young Hak Roh, Moon Sang Chung, Goo Hyun Baek, Young Ho Lee, Hyuk-Jin Lee, Joon Oh Lee, Kyu-Won Oh, Hyun Sik Gong Journal of the Korean Fracture Society.2010; 23(2): 194. CrossRef