PURPOSE To evaluate the clinical and radiological results of minimally invasive plate, osteosynthesis, using either a locking compression plate-distal tibia (LCP-DT) or Zimmer periarticular locking plate (ZPLP) for distal tibia fractures. MATERIALS AND METHODS Fifty one patients (51 cases), who underwent minimally invasive osteosynthesis using locking compression plate for distal tibia fractures between October 2008 and August 2011, were followed for more than six months. Eighteen patients were treated with LCP-DT and 33 patients with ZPLP. Time to bony union and anatomic alignment were evaluated radiologically. Clinically, American Orthopedic Foot & Ankle Society ankle-hindfoot scales (AOFAS score) and range of ankle motion were assessed and compared between two groups. RESULTS All patients achieved bony union at an average of 18 weeks on LCP-DT group and 16weeks on ZPLP group. The average American Orthopedic Foot & Ankle Society ankle-hindfoot scales was 83.3 points on the LCP-DT group, 84.6 points on the ZPLP group, and range of ankle motion averaged at 45 degrees, 48 degrees, respectively. CONCLUSION Both types of locking compression plates were effective when performing minimally invasive osteosynthesis for distal tibia fractures.
Citations
Citations to this article as recorded by
Biomechanical analysis and clinical effects of bridge combined fixation system for femoral fractures Da-xing Wang, Ying Xiong, Hong Deng, Fu Jia, Shao Gu, Bai-lian Liu, Qun-hui Li, Qi Pu, Zhong-zi Zhang Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine.2014; 228(9): 899. CrossRef
PURPOSE To acknowledge the importance of precise reduction of articular surface of tibial plateau fractures and to make a guideline of treatment by evaluating outcomes and effectiveness of using locking plate and minimally invasive percutaneous osteosynthesis technique. MATERIALS AND METHODS Twenty-nine patients who underwent surgery for tibial plateau fracture from November 2005 to March 2010 were enrolled with 12 months follow-up in a retrograde manner. The Shatzker classification was used to classify fractures, and we used lateral submeniscal approach to make a precise reduction of articular surface. Radiologic evaluation was determined by presence of bone union, malalignment, and reduction loss or joint depression of articular surface. Post-operative infection, time of active movement of the knee joint, time of partial weight loading, and range of motion (ROM) of knee joint were evaluated. Lysholm Knee Score was used for functional evaluation. RESULTS Bone union took place in all but one case that developed osteomyelitis. Angulation deformity of more than 10degrees and reduction loss or joint depression of more than 5 mm were not observed. There was one case of osteomyelitis and one case of superficial surgical site infection. There were satisfactory clinical results, with an average time of active knee joint movement and weight loading of 6 weeks. The average ROM of knee joint was 125degrees in the last follow up. As for functional evaluation using Lysholm Knee Score, cases showed an average Lysholm Knee Score of 94 which was a satisfactory result. CONCLUSION In cases of tibial plateau fractures, if a surgeon accurately reduces the articular surface of joint and use minimally invasive locking plate it will help in bone union biologically, reducing the incidence of soft tissue injuries, and biomechanically maintaining the articular surface of the joint, proving itself to be a useful method of treatment.
PURPOSE To compare results between minimally invasive plate osteosynthesis using a periarticular plate and intramedullary nailing in distal tibial metaphyseal fractures in two treatment groups. MATERIALS AND METHODS Sixty-one cases of distal tibial metaphyseal fractures from December 2008 to December 2009 were evaluated. The minimal follow-up period was 12 months. Thirty patients treated by minimally invasive plate osteosynthesis using a periarticular plate were Group A; 31 patients treated by intramedullary nailing were Group B. We compared and analyzed the results of each group by radiological and clinical assessments. RESULTS The mean bony union time was 16.4 weeks in Group A and 17.2 weeks in Group B. The mean operation time was 45 minutes in Group A and 48 minutes in Group B. The mean radiation exposure times were 4.2 minutes and 4.8 minutes, respectively. VAS scores were 0.7 points and 0.5 points in each respective group. In Group A, the VAS score was 1.7 points when we applied pressure on the skin around the plate. The mean Olerud and Molander Ankle Score was 87.4 points and 86.3 points, respectively. A superficial wound infection occurred in 1 case in each group, and angular deformities more than 5 degrees occurred in 2 Group B cases. CONCLUSION No significant differences in results were observed between the two groups. However, a higher incidence of angular deformity was seen in the intramedullary nailing group. Therefore, we must be careful during surgery.
Citations
Citations to this article as recorded by
Comparative Analysis of Minimally Invasive Plate Osteosynthesis and Intramedullary Nailing in the Treatment of the Distal Tibia Fractures Ho-Min Lee, Young-Sung Kim, Jong-Pil Kim, Phil-Hyun Chung, Suk Kang, Kaung Suk Jo Journal of the Korean Fracture Society.2018; 31(3): 94. CrossRef
A Comparison of the Results between Intramedullary Nailing and Minimally Invasive Plate Osteosynthesis in Distal Tibia Fractures Chul-Hyun Park, Chi-Bum Choi, Bum-Jin Shim, Dong-Chul Lee, Oog-Jin Shon Journal of the Korean Orthopaedic Association.2014; 49(4): 285. CrossRef
PURPOSE We evaluated the efficacy and results of minimally invasive anterior plating for humeral shaft fracture. MATERIALS AND METHODS Twenty-two cases of humeral shaft fracture were reviewed, including 8 cases of type A, 8 of type B and 6 of type C (AO/OTA classification). There were three open fractures. The fracture was fixed with MIPO (minimally invasive plate osteosynthesis) technique under C-arm guide. A locking compression plate was located in anterior aspect of the humerus with at least three screws fixed in each fragment. Radiologic and functional results were evaluated. RESULTS In 20 of 22 cases, bony union was achieved with the mean period of 17.5 weeks, including 2 cases of delayed union. There were 2 cases of nonunion, which needed the further operative procedure. Except one case of distal 1/3 fracture, all cases showed satisfactory elbow and shoulder function with the mean Mayo elbow score of 17.4 and mean UCLA shoulder score of 97.3. In complication, there was one case of radial nerve palsy due to improper traction, but it was completely improved after 3 months. Otherwise, there was no complication including infection. CONCLUSION Anterior MIPO for humeral shaft fracture may be another option of operative methods with high union and low complication rate.
Citations
Citations to this article as recorded by
Minimal Invasive Plate Osteosynthesis versus Conventional Open Plating in Simple Humeral Shaft Fracture (AO Type A, B1, B2) Boseon Kim, GwangChul Lee, Hyunwoong Jang Journal of the Korean Fracture Society.2017; 30(3): 124. CrossRef
Clinical and Radiographical Follow-up for Residual Displacement of Fracture Fragments after Interlocking Intramedullary Nailing in Humeral Shaft Fractures Jae-Kwang Yum, Dong-Ju Lim, Eui-Yub Jung, Su-Een Sohn The Journal of the Korean Shoulder and Elbow Society.2013; 16(2): 107. CrossRef
Operative Treatment of Humerus Shaft Fracture: Conventional Open Plating or Minimally Invasive Plate Osteosynthesis Hyun-Joo Lee, Chang-Wug Oh Journal of the Korean Fracture Society.2012; 25(2): 155. CrossRef
PURPOSE To report the method of anatomical reduction and its maintenance by percutaneous wiring reduction in minimally invasive plate osteosynthesis for distal tibial fractures. MATERIALS AND METHODS 17 cases that were diagnosed oblique, spiral or transverse fracture of distal tibia from August 2007 to February 2010 and were able to anatomically reduce by the method of percutanous wiring reduction in minimally invasive plate osteosynthesis were included in this study. Mean age was 50, and mean follow up period was 18 months. We investigated the period until bone union was achieved, degree of angulation angle, and complications. For postoperative evaluation, Olerud and Molander ankle score and VAS pain score in daily living were checked. RESULTS The mean varus/valgus angulation after bone union on AP radiograph was 0.9 degrees and the mean anterior/posterior angulation on lateral radiograph was 2.0 degrees The mean Olerud and Molander ankle score was 89.4, and mean pain score due to walk adjacent to metal plate was 0 points. CONCLUSION By the method of percutaneous wiring reduction in distal tibial fracture, anatomical reduction is easily acquired, and only by wire itself, reduction could be maintained, so that without additional manual reduction, plate could be easily fixed.
PURPOSE To report the results of patients treated by minimally invasive plate osteosynthesis (MIPO) for proximal tibial shaft fractures. MATERIALS AND METHODS From September 2003 to June 2008, thirty-two patients with proximal tibial shaft fractures weretreated by MIPO. There were 22 men and 10 women and mean age was 43.8 years (range; 21~72 years). Follow-up was available for all patients and the mean follow-up period was 19.5 months (range; 12~40 months). Duration of union, range of knee motion and postoperative complications were evaluated. RESULTS Twenty-nine patients (90.6%) healed after the MIPO technique. The mean duration of radiographic union was 18.3 weeks (range; 10~28 weeks). The mean range of knee motion was 134 degrees at the last follow-up. There were 1 non-union, 2 delayed unions, 1 superficial infection, 1 deep infection, 2 malunions with more than 5 degrees of malalignment and 14 cases of skin irritation by plate. CONCLUSION MIPO is an effective treatment for closed, proximal tibialshaft fractures. More aggressive treatment such as dual plating should be considered in fractures with severe comminution or bone loss.
Citations
Citations to this article as recorded by
Medial Minimally Invasive Percutaneous Plate Osteosynthesis in Proximal Tibial Comminuted Fractures Jae-Ang Sim, Kwang-Hui Kim, Yong-Seuk Lee, Sang-Jin Lee, Beom-Koo Lee Journal of the Korean Orthopaedic Association.2014; 49(4): 278. CrossRef
Minimally Invasive Percutaneous Plate Stabilization Using a Medial Locking Plate for Proximal Tibial Fractures - Technical Note - Jae Ang Sim, Beom Koo Lee, Kwang Hui Kim, Yong Seuk Lee Journal of the Korean Fracture Society.2013; 26(4): 327. CrossRef
PURPOSE To compare the result of treatment between minimally invasive plate osteosynthesis (MIPO) using periarticular plate and intramedullary nailing in treatment of distal tibia fractures. MATERIALS AND METHODS 28 cases of distal tibia fractures form Jan. 2006 to Mar. 2008 were divided into two group. Minimum follow-up was for 12 month. Group 1 consisted of 14 patients who were treated by MIPO technique and group 2 consisted of 14 patients who were treated by interlocking intramedullary nailing. The results were compared by assessing radiologic and clinical result. RESULTS The mean bony union time was 14 weeks (8~17) in group 1 and 15 weeks (11~20) in group 2. Operation time was 58 minutes (55~65) in group 1 and 82.7 minutes (70~100) in group 2. The average angulation in AP view was 1.5 degrees (0~2) in group 1 and 2 degrees (0~5) in group 2, in lateral view was 1.8 degrees (0~4) in group 1 and 2.3 degrees (0~12) in group 2. The average range of motion for dorsi flextion was 17.5 degrees (15~20) in group 1 and 18 degrees (16~20) in group 2, for plantar flextion was 45 degrees (42~50) in group 1 and 44 degrees (42~50) in group 2, which means that there were no severe limitation of motion in all patients, resulting in satisfactory ambulation. There was no post operative complications such as skin irritation problem caused by internal device and no implant failure and superficial wound infection. CONCLUSION There were no difference in bony union time, clinical result and anatomical reduction between Group 1 and Group 2 in distal tibia fractures, but operation time was shorter in MIPO than nailing.
PURPOSE We wanted to evaluate the efficacy of MIPO (minimal invasive plate osteosynthesis) technique by LCP (locking compression plate) for treating proximal tibia fractures. MATERIALS AND METHODS Twenty-three patients, who had operation due to proximal tibia fracture and available for follow up for more than 1 year were included in this study. Cause of injury and accompanied injuries were checked. Operation time, period to bone union, range of joint motion and alignment were evaluated with complications. RESULTS Mean bone union time was 13.7 weeks (10~20). Twenty-one cases of the patients showed angulation of less than 5 degrees and 17 cases had normal range of motion. Five cases showed skin irritation by the plate and 2 cases had superficial infection. CONCLUSION LCP by MIPO technique for treating proximal tibia fracture showed excellent results. Delicate technique is required for the proper adjustment of LCP and the alignment of the lower leg.
Citations
Citations to this article as recorded by
EVALUATION OF FUNCTIONAL OUTCOME OF SURGICAL TREATMENT FOR FRACTURE AROUND KNEE WITH LOCKING PLATE VIKAS KUNTWAD, AMOL WAGH, SATYAJEET A HORE Asian Journal of Pharmaceutical and Clinical Research.2023; : 213. CrossRef
Medial Minimally Invasive Percutaneous Plate Osteosynthesis in Proximal Tibial Comminuted Fractures Jae-Ang Sim, Kwang-Hui Kim, Yong-Seuk Lee, Sang-Jin Lee, Beom-Koo Lee Journal of the Korean Orthopaedic Association.2014; 49(4): 278. CrossRef
Minimally Invasive Percutaneous Plate Stabilization Using a Medial Locking Plate for Proximal Tibial Fractures - Technical Note - Jae Ang Sim, Beom Koo Lee, Kwang Hui Kim, Yong Seuk Lee Journal of the Korean Fracture Society.2013; 26(4): 327. CrossRef
PURPOSE To compare the effectiveness between minimally invasive plate osteosynthesis (MIPO) and interlocking IM nailing in the treatment of distal tibia fracture without involvement of ankle joint retrospectively. MATERIALS AND METHODS 38 patients with distal tibia fracture from Jan. 2004 to Oct. 2005 were divided into two groups. Minimum follow-up was for 12 months. Group MIPO consisted of 18 patients were treated with MIPO and group Nail consisted of 20 patients were treated with interlocking intramedullary nail. The results were compared between two groups by assessing bony union time and operation time. Clinical evaluation was evaluated by Olerud score. RESULTS The mean bony union time was 14.4 weeks (12~17 weeks) in group MIPO and 16.7 weeks (13~19 weeks) in group Nail (p=0.011). The mean operation time was 1.05 hours (0.6~1.6 hours) in group MIPO and 0.74 hours (0.4~1.1 hours) in group Nail (p=0.044). The Olerud score was 83.8 (75~100) in group MIPO and was 89.6 (70~100) in group Nail (p=0.075). In Complication, group MIPO showed one metal failure and two skin irritations, group Nail showed three superficial wound infections. CONCLUSION MIPO was the shorter bony union time and the longer operation time than the interlocking intramedullary nailing. There were no significant differences between the two groups in clinical results.
Citations
Citations to this article as recorded by
Comparative Analysis of Minimally Invasive Plate Osteosynthesis and Intramedullary Nailing in the Treatment of the Distal Tibia Fractures Ho-Min Lee, Young-Sung Kim, Jong-Pil Kim, Phil-Hyun Chung, Suk Kang, Kaung Suk Jo Journal of the Korean Fracture Society.2018; 31(3): 94. CrossRef
A Rehabilitation for Ankle Fracture in Korean Medicine: A Report of 4 Cases Won-Bae Ha, Jong-Ha Lee, Yoon-Seung Lee, Dong-Chan Jo, Jin-Hyun Lee, Jung-Han Lee Journal of Korean Medicine Rehabilitation.2017; 27(4): 171. CrossRef
Comparison of the Results between Intramedullary Nailing and Plate Fixation for Distal Tibia Fractures Jung-Han Kim, Heui-Chul Gwak, Chang-Rack Lee, Yang-Hwan Jung Journal of Korean Foot and Ankle Society.2015; 19(3): 86. CrossRef
Intramedullary Nailing of Distal Tibial Fractures with Percutaneous Reduction by Pointed Reduction Forceps Jae-Kwang Hwang, Chung-Hwan Kim, Young-Joon Choi, Gi-Won Lee, Hyun-Il Lee, Tae-Kyung Kim Journal of the Korean Fracture Society.2014; 27(2): 144. CrossRef
A Comparison of the Results between Intramedullary Nailing and Minimally Invasive Plate Osteosynthesis in Distal Tibia Fractures Chul-Hyun Park, Chi-Bum Choi, Bum-Jin Shim, Dong-Chul Lee, Oog-Jin Shon Journal of the Korean Orthopaedic Association.2014; 49(4): 285. CrossRef
Analysis of the Result Treated with Locking Compression Plate-Distal Tibia and Zimmer Periarticular Locking Plate in Distal Tibia Fracture Jun-Young Lee, Sang-Ho Ha, Sung-Won Cho, Sung-Hae Park Journal of the Korean Fracture Society.2013; 26(2): 118. CrossRef
PURPOSE To evaluate the outcomes of patients with comminuted subtrochanteric femoral fractures using minimally invasive plate osteosynthesis (MIPO) technique. MATERIALS AND METHODS Twelve patients with a mean age of 38.2 years, who sustained comminuted subtrochanteric femoral fractures, were treated using MIPO technique. All patients suffered these fractures either from traffic accidents (6) or falls from height (6). Average follow-up was 4.3 years (range, 29~78 months). Patients were assessed radiographically and clinically with regards to time to union, malunion, and complications. According to the Seinsheimer's classification, there were 1 type III, 7 type IV, and 4 type V. Type C fractures were ten according to AO-OTA classification. RESULTS Union was achieved in 7 of 12 cases, in an average of 23.4 weeks (range, 12~42 weeks). Three definite non-unions with implant failures, needed the procedure of implant change and bone graft. In other two patients, early bone graft was performed for anticipated nonunion of comminuted area. The most common complication was metal failures (2 plate failures and 3 screw breakages). Limb length shortening of 1.5 cm occurred in one patient, and external rotation malunion of 15 degrees was noted in one patient. No patients developed infection. CONCLUSION Preserving biology of the fracture fragments, the use of MIPO technique using DCS has proven to be less successful in comminuted subtrochanteric fractures, comparing to fractures in other areas. To avoid mechanical failure, the careful and protective weight bearing is needed until the callus-bridging is seen in the commniuted area.
Citations
Citations to this article as recorded by
Minimally Invasive Plate Osteosynthesis for Femoral Mid-Diaphyseal Fractures Hyoung-Keun Oh, Suk-Kyoo Choo, Jong-In Kim, Sung-Jong Woo Journal of the Korean Fracture Society.2013; 26(2): 140. CrossRef
Fixation of the Femoral Subtrochanteric Fracture with Minimally Invasive Reduction Techniques Chul-Hyun Park, Chul-Wung Ha, Sang-Jin Park, Min-Su Ko, Oog-Jin Shon Journal of the Korean Fracture Society.2013; 26(2): 112. CrossRef
Minimally Invasive Plate Osteosynthesis of Subtrochanteric Femoral Fractures Chang-Wug Oh Journal of the Korean Fracture Society.2009; 22(2): 123. CrossRef
What is an Ideal Treatment? Chang-Wug Oh Journal of the Korean Fracture Society.2008; 21(4): 347. CrossRef
PURPOSE To evaluate the efficiency of lateral plate fixation using minimally invasive plate osteosynthesis (MIPO) technique as a treatment of distal tibial metaphyseal fracture. MATERIALS AND METHODS Among the patient who were treated from March, 2002 to September, 2004, the cases of twenty patients with distal tibial metaphyseal fracture treated by lateral plate fixation using MIPO technique who were able to be followed up for at least one-year period were reviewed in this study. According to AO/OTA classification, five were type A1, twelve cases were type A2 and other three cases were type A3, and among them two cases were open fracture type I according to the Gustillo-Anderson classification. Radiologic studies and clinical assessment described by Daniel et al and complication following the treatment were evaluated. RESULTS At a mean of 16.4 weeks (range 11 to 23), all fractures united without secondary procedures. According to clinical assessment, all cases had good and excellent result, and there were no complications. CONCLUSION The lateral plate fixation using MIPO technique of distal tibial metaphyseal fracture is an efficient method of treatment with high functional recovery rate which minimize soft tissue damage, decreases the risk of infection and incidence of nonunion at the same time as the classic MIPO technique does, and it is a useful alternative method when there is a anteromedial soft tissue damage.
Citations
Citations to this article as recorded by
Minimally Invasive Plate Osteosynthesis for Fractures of Distal Tibia Tae Hun Kim, So Hak Chung Kosin Medical Journal.2014; 29(1): 23. CrossRef
Staged Protocol in Treatment of Open Distal Tibia Fracture: Using Lateral MIPO Oog Jin Sohn, Dong Hwa Kang Clinics in Orthopedic Surgery.2011; 3(1): 69. CrossRef
Minimally Invasive Percutaneous Plate Osteosynthesis Using a Lateral Plate in Distal Tibial Fracture Oog Jin Shon, Dae Sung Kim Journal of the Korean Fracture Society.2010; 23(1): 42. CrossRef
PURPOSE To retrospectively reviewed the outcomes and advantages of minimally invasive plate osteosynthesis (MIPO) technique as a new treatment of distal tibial metaphyseal fracture. MATERIALS AND METHODS Nineteen distal tibial metaphyseal fractures were treated by MIPO technique and evaluated radiologically and functionally. A mean age was 46 years old (range 20~69 years) and a mean follow-up was 15 months (range 6~37 months). Sixteen fractures were not extended into ankle joint (AO/OTA type A1;4, A2;8, A3;4) and three fractures were extended into ankle joint (AO/OTA type C1;2, C2;1). Two cases were open fractures (type I;1, type III-A;1) according to the Gustilo-Anderson classification. RESULT At a mean of 18 weeks (range 12 to 24), all fractures united without secondary procedures. A mean score was 94.2 point by Baird ankle scoring system. There were no complications including shortening over 1 cm, mal-alignment over 5 degrees, deep infection, or implant failure. CONCLUSION MIPO technique of distal tibial metaphyseal fracture is a worthwhile method with good unions and functional recovery.
Citations
Citations to this article as recorded by
Comparative Analysis of Minimally Invasive Plate Osteosynthesis and Intramedullary Nailing in the Treatment of the Distal Tibia Fractures Ho-Min Lee, Young-Sung Kim, Jong-Pil Kim, Phil-Hyun Chung, Suk Kang, Kaung Suk Jo Journal of the Korean Fracture Society.2018; 31(3): 94. CrossRef
A Comparison of the Results between Intramedullary Nailing and Minimally Invasive Plate Osteosynthesis in Distal Tibia Fractures Chul-Hyun Park, Chi-Bum Choi, Bum-Jin Shim, Dong-Chul Lee, Oog-Jin Shon Journal of the Korean Orthopaedic Association.2014; 49(4): 285. CrossRef
Analysis of the Result Treated with Locking Compression Plate-Distal Tibia and Zimmer Periarticular Locking Plate in Distal Tibia Fracture Jun-Young Lee, Sang-Ho Ha, Sung-Won Cho, Sung-Hae Park Journal of the Korean Fracture Society.2013; 26(2): 118. CrossRef
Comparative Analysis of Minimally Invasive Plate Osteosynthesis Using Periarticular Plate and Intramedullary Nailing in Distal Tibial Metaphyseal Fractures Gwang Chul Lee, Jun Young Lee, Sang Ho Ha, Hong Moon Sohn, Yi Kyu Park Journal of the Korean Fracture Society.2012; 25(1): 20. CrossRef
Clinical Outcomes of Locking Compression Plate Fixation through Minimally Invasive Percutaneous Plate Osteosynthesis in the Treatment of Distal Tibia Fracture Jae-Sung Yoo, Hyun-Woo Park Journal of the Korean Fracture Society.2012; 25(2): 117. CrossRef
Minimally Invasive Osteosynthesis with Locking Compression Plate for Distal Tibia Fractures Sung-Kyu Kim, Keun-Bae Lee, Keun-Young Lim, Eun-Sun Moon Journal of the Korean Fracture Society.2011; 24(1): 33. CrossRef
Management of Fractures of Distal Tibia by Minimally Invasive Plate Osteosynthesis through an Anterior Approach Gu-Hee Jung, Jae-Do Kim, Jae-Ho Jang, Sung-Keun Heo, Dong-won Lee Journal of the Korean Orthopaedic Association.2010; 45(6): 473. CrossRef
Comparative Study Using of Treatment with Minimally Invasive Plate Osteosynthesis Using Periarticular Plate and Interlocking Intramedullary Nailing in Distal Tibia Fractures Chang Hwa Hong, Jong Seok Park, Sang Seon Lee, Soo Ik Awe, Woo Jong Kim, Ki Jin Jung Journal of the Korean Fracture Society.2010; 23(3): 296. CrossRef
A Comparison between Minimally Invasive Plate Osteosynthesis & Interlocking Intramedullary Nailing in Distal Tibia Fractures Kee-Byung Lee, Si-Young Song, Duek-Joo Kwon, Yong-Beom Lee, Nam-Kyou Rhee, Jun-Ha Choi Journal of the Korean Fracture Society.2008; 21(4): 286. CrossRef
Minimally Invasive Percutaneous Plate Osteosynthesis Using Periarticular Plate for Distal Tibial Fractures Young Mo Kim, Jae Hoon Yang, Dong Kyu Kim Journal of the Korean Fracture Society.2007; 20(4): 315. CrossRef
Treatment of High-energy Distal Tibia Intraarticular Fractures with Two-staged Delayed Minimal Invasive Plate Osteosynthesis Hong-Moon Sohn, Jun-Young Lee, Sang-Ho Ha, Jae-Won You, Sang-Hong Lee, Kwang-Chul Lee Journal of the Korean Fracture Society.2007; 20(1): 19. CrossRef
OBJECTIVES To evaluate the results and its efficacy of double plating for proximal tibial fractures using minimally invasive percutaneous osteosynthesis (MIPO) technique.
MATERIAL & METHODS: Twenty-three fractures, followed-up more than 1 year, were included in this retrospective study. There were 18 men and 5 women, and the mean age was 53.5 years-old. According to the AO-OTA classification, five were 41A, 13 were 41C, and 5 were 42. There were four open fractures (grade I- three, grade III A-one case). The plates were fixed on the medial and lateral sides of tibia with MIPO technique. Functional and radiographic results were evaluated by the modified Rasmussen system. RESULTS All fractures healed without bone graft, and the mean period for fracture healing was 19.3 weeks (range, 10~32 weeks). All other patients had excellent or good clinical or radiological results, except for two patients of a fair clinical result after a combined injury. Complications included one case of shortening (1 cm) and two cases of mal-alignments (varus less than 10 degrees). There was one case of superficial infection, but no patient showed deep infection. CONCLUSION Double plating using MIPO technique can provide favorable results in the treatment of proximal tibial fractures.
Citations
Citations to this article as recorded by
Medial Minimally Invasive Percutaneous Plate Osteosynthesis in Proximal Tibial Comminuted Fractures Jae-Ang Sim, Kwang-Hui Kim, Yong-Seuk Lee, Sang-Jin Lee, Beom-Koo Lee Journal of the Korean Orthopaedic Association.2014; 49(4): 278. CrossRef
Minimally Invasive Plate Osteosynthesis for Proximal Tibial Shaft Fracture Young-Soo Byun, Ki-Chul Park, Hyun-Jong Bong, Chang-Hoon Lee Journal of the Korean Fracture Society.2011; 24(1): 23. CrossRef
Treatment of Proximal Tibia Fractures Using LCP by MIPO Technique Sang-Ho Ha, Dong-Hui Kim, Jun-Young Lee Journal of the Korean Fracture Society.2010; 23(1): 34. CrossRef
Staged Minimally Invasive Plate Osteosynthesis of Proximal Tibial Fracture Joon-Woo Kim, Chang-Wug Oh, Jong-Keon Oh, Hee-Soo Kyung, Woo-Kie Min, Byung-Chul Park, Kyung-Hoon Kim, Hee-Joon Kim Journal of the Korean Fracture Society.2009; 22(1): 6. CrossRef
PURPOSE evaluate the effectiveness of minimally invasive plate osteosynthesis (MIPO) in unstable fractures of the distal tibia. MATERIALS AND METHODS From March 2001 to December 2003, 21 cases with unstable fractures of the distal tibia were treated with MIPO technique and followed for at least one year. Eighteen cases were extra-articular and three cases were intra-articular fractures. According to AO classification, six cases were 42-A, four 42-B, one 42-C, seven 43-A, and three 43-C. There was only one case of Gustilo-Anderson type II open fracture. We reviewed the results of fracture healing, axial and rotational deformity, ankle motion, and complications RESULTS: All fractures were healed in an average of 16.1 weeks (range, 11 to 24 weeks). There was only one case of 7-degree posterior angular deformity, but no cases of rotational malalignment. Recovery of ankle motion was satisfactory in all patients within 5-degree loss of motion. Subcutaneous abscess was developed in one case after fracture healing and cured by a drainage with implant removal. CONCLUSION Although MIPO technique is technically more demanding than the traditional open technique, MIPO technique is an effective method for unstable fractures of the distal tibia because it minimizes incidence of soft-tissue compromise and infection and provides good fracture healing.
Citations
Citations to this article as recorded by
Clinical Outcomes of Locking Compression Plate Fixation through Minimally Invasive Percutaneous Plate Osteosynthesis in the Treatment of Distal Tibia Fracture Jae-Sung Yoo, Hyun-Woo Park Journal of the Korean Fracture Society.2012; 25(2): 117. CrossRef
Staged Protocol in Treatment of Open Distal Tibia Fracture: Using Lateral MIPO Oog Jin Sohn, Dong Hwa Kang Clinics in Orthopedic Surgery.2011; 3(1): 69. CrossRef
Staged Minimally Invasive Plate Osteosynthesis of Distal Tibial Fractures Sung-Ki Park, Chang-Wug Oh, Jong-Keon Oh, Kyung-Hoon Kim, Woo-Kie Min, Byung-Chul Park, Won-Ju Jeong, Joo-Chul Ihn Journal of the Korean Fracture Society.2010; 23(3): 289. CrossRef
Management of Fractures of Distal Tibia by Minimally Invasive Plate Osteosynthesis through an Anterior Approach Gu-Hee Jung, Jae-Do Kim, Jae-Ho Jang, Sung-Keun Heo, Dong-won Lee Journal of the Korean Orthopaedic Association.2010; 45(6): 473. CrossRef
Comparative Study Using of Treatment with Minimally Invasive Plate Osteosynthesis Using Periarticular Plate and Interlocking Intramedullary Nailing in Distal Tibia Fractures Chang Hwa Hong, Jong Seok Park, Sang Seon Lee, Soo Ik Awe, Woo Jong Kim, Ki Jin Jung Journal of the Korean Fracture Society.2010; 23(3): 296. CrossRef
A Comparison between Minimally Invasive Plate Osteosynthesis & Interlocking Intramedullary Nailing in Distal Tibia Fractures Kee-Byung Lee, Si-Young Song, Duek-Joo Kwon, Yong-Beom Lee, Nam-Kyou Rhee, Jun-Ha Choi Journal of the Korean Fracture Society.2008; 21(4): 286. CrossRef
Basic Principle of the Locking Compression Plate Keun Bae Lee Journal of the Korean Fracture Society.2008; 21(3): 261. CrossRef
Treatment of High-energy Distal Tibia Intraarticular Fractures with Two-staged Delayed Minimal Invasive Plate Osteosynthesis Hong-Moon Sohn, Jun-Young Lee, Sang-Ho Ha, Jae-Won You, Sang-Hong Lee, Kwang-Chul Lee Journal of the Korean Fracture Society.2007; 20(1): 19. CrossRef
Minimally Invasive Plate Osteosynthesis, MIPO Young-Soo Byun Journal of the Korean Fracture Society.2007; 20(1): 99. CrossRef
Minimally Invasive Percutaneous Plate Osteosynthesis Using Periarticular Plate for Distal Tibial Fractures Young Mo Kim, Jae Hoon Yang, Dong Kyu Kim Journal of the Korean Fracture Society.2007; 20(4): 315. CrossRef
PURPOSE We retrospectively reviewed the outcomes and advantages of minimal invasive plating osteosynthesis (MIPO) technique as a new treatment of distal femoral fractures. MATERIALS AND METHODS Sixteen supracondylar femoral fractures (15 patients) were treated by MIPO technique and evaluated radiologically and functionally after minimal 1 year follow-up (average; 22 months, range; 13~42 months). There were 9 women and 6 men with a mean age of 46 years old (range 35 to 64 years). Seven fractures were extended into knee joints (AO/OTA type C), and 9 were extraarticular (AO/OTA type A). Five cases were open fractures (type I; 2, type II; 3) according to the Gustilo-Anderson classification. After minimal lateral parapatellar incision and accurate reduction of intra-articular fractures, the supracondylar fractures were fixed by percuatneous plating method without exposure of fracture area. Neer scoring was used for functional evaluation of knee. RESULT At a mean of 17 weeks (range 14 to 22), most fractures united without secondary procedures. One case of nonunion had the procedure of bone graft, but there were no other complications including shortening over 1 cm, mal-alignment over 10 degrees, or deep infections. All the cases had good or excellent knee function, and the average range of knee motion was 120.6 degrees. CONCLUSION MIPO technique is a worthwhile method of managing distal femoral fractures with good unions and functional recovery.
Citations
Citations to this article as recorded by
The Comparison of Minimally Invasive Percutaneous Plate Osteosynthesis versus Open Plate Fixation in the Treatment of in the Distal Femur Fracture Seong-Jun Ahn, Suk-Woong Kang, Bu-Hwan Kim, Moo-Ho Song, Seong-Ho Yoo, Kwan-Taek Oh Journal of the Korean Fracture Society.2013; 26(4): 314. CrossRef
Treatment of Distal Femur Fracture with Minimally Invasive Locking Compression Plate Osteosynthesis Ki-Chul Park, Kyu-Sung Chung, Joon-Ki Moon Journal of the Korean Fracture Society.2012; 25(1): 13. CrossRef
Axial Malalignment after Minimally Invasive Plate Osteosynthesis in Distal Femur Fractures with Metaphyseal Comminution Jae-Ho Jang, Gu-Hee Jung, Jae-Do Kim, Cheung-Kue Kim Journal of the Korean Orthopaedic Association.2011; 46(4): 326. CrossRef
Surgical Treatment of AO Type C Distal Femoral Fractures Using Locking Compression Plate (LCP-DF, Synthes®) Kap-Jung Kim, Sang Ki Lee, Won-Sik Choy, Won-Cho Kwon, Do Hyun Lee Journal of the Korean Fracture Society.2010; 23(1): 20. CrossRef
What is an Ideal Treatment? Chang-Wug Oh Journal of the Korean Fracture Society.2008; 21(4): 347. CrossRef
PURPOSE To evaluate the advantages of fixation of metaphysis by minimally invasive plate osteosynthesis(MIPO) technique for comminuted fractures of the proximal tibia.
MATERIALS & METHODS: from January 1997 to February 2000, 18 cases of comminuted fracture of the proximal tibia were treated using MIPO technique. Operation time, union time, radiologic alignment, range of motion of the knee joint, functional and anatomical results according to Rassmusen's grading criteria, complications were evaluated. Minimal follow-up time was 12 months. RESULTS Operation time was average 51 minutes (30-80 minutes). Time to bone healing was average 10.6 weeks (9-14 weeks) There was 1 case of valgus angular deformity greater than 5 degrees. 6 cases in acceptable bony alignment less than valgus 5 degrees and 11 cases were classified into normal bony alignment. Range of motion of the knee joint was 0-140 degrees in 13 cases, 0-120 degrees in 3 cases, 0-90 degrees in 1 case, 10-90 degrees in 1 case. Rasmussen's grading criteria for functional outcome revealed there were 14 cases(77.8%) excellent results, 4 cases(22.2%) good result. and grading criteria for anatomical outcome revealed there were 7 cases(38.9%) excellent results, 11 cases(61.1%) good result. CONCLUSION MIPO technique for comminuted fracture of the proximal tibia seems to be a good techinque to obtain more rapid bony union with less complication.
Citations
Citations to this article as recorded by
Treatment of Proximal Tibia Fractures Using LCP by MIPO Technique Sang-Ho Ha, Dong-Hui Kim, Jun-Young Lee Journal of the Korean Fracture Society.2010; 23(1): 34. CrossRef
PURPOSE To evaluate the advantages of transarticular reconstruction and fixation of metaphysis by MIPO technique for AO type C2-C3 fractures of the distal femur.
MATERIAL AND METHODS: In a retrospective study conducted from January 1996 to December 1997, AO type C2-C3 fractures of the distal femur were treated using three techniques; 1) A group-MIPO technique and medial parapatellar arthrotomy for the direct reduction of the condylar block(10 cases), 2) B group-conventional AO technique(8 cases) 3) C group-closed supracondylar nailing(4 cases). Minimal followup time was 12 months. RESULTS Time to bone healing was 15 weeks in A group, 20 weeks in B group, and 16 weeks in C group. complication rate was 0% in A group, 50% in B group, and 50% in C group. normal alignment between 0 & valgus 9 degrees was 100% in A group, 75% in B group, and 50% in C group. Neer score was 90% excellent or satisfactory in A group, 75% in B group, and 50% in C group respectively. The results of A group was better than those of B and C group. CONCLUSION Transarticular joint reconstruction and MIPO technique for AO type C2-C3 fractures of the distal femur is an excellent technique to obtain more rapid bony union with less complications.