Skip Navigation
Skip to contents

J Musculoskelet Trauma : Journal of Musculoskeletal Trauma

OPEN ACCESS

Search

Page Path
HOME > Search
5 "Hyung Soo Kim"
Filter
Filter
Article category
Keywords
Publication year
Authors
Original Article
Comparative Analysis of the Results of Fixed-angle versus Variable-angle Volar Locking Plate for Distal Radius Fracture Fixation
Seung Do Cha, Jai Hyung Park, Hyung Soo Kim, Soo Tae Chung, Jeong Hyun Yoo, Joo Hak Kim, Jung Hwan Park
J Korean Fract Soc 2012;25(3):197-202.   Published online July 31, 2012
DOI: https://doi.org/10.12671/jkfs.2012.25.3.197
AbstractAbstract PDF
PURPOSE
To compare the outcomes of distal radius fractures in a fixed-angle volar locking plate group and variable-angle volar locking plate group.
MATERIALS AND METHODS
Forty-one patients observed at least 6 months after surgery were included in this retrospective study. We used the range of motion, visual analogue scale score, Disabilities of the Arm, Shoulder and Hand Questionnaire score, and radiologic findings to measure the clinical results.
RESULTS
No differences in clinical results or radiologic results were noted between the fixed-angle volar locking plate group and variable-angle volar locking plate group.
CONCLUSION
We believe that it is important to minimize complications by using appropriate screws and plates according to the fracture type, though no differences in the surgical outcome were noted between the fixed-angle volar locking plate group and variable-angle volar locking plate group with distal radius fracture.

Citations

Citations to this article as recorded by  
  • Volar locking plate fixation for distal radius fractures: did variable-angle plates make difference?
    Mohamed Abdel-Wahed, Ahmed Abdel-Zaher Khater, Mahmoud Ahmed El-Desouky
    International Orthopaedics.2022; 46(9): 2165.     CrossRef
  • Treatment of Fractures of the Distal Radius Using Variable-Angle Volar Locking Plate
    Jae-Cheon Sim, Sung-Sik Ha, Ki-Do Hong, Tae-Ho Kim, Min-Chul Sung
    Journal of the Korean Fracture Society.2015; 28(1): 46.     CrossRef
  • Functional Outcomes of Percutaneous K-Wire Fixation for Distal Radius Fractures with or without Osteoporosis
    Ki-Chan An, Gyu-Min Kong, Jang-Seok Choi, Hi-Chul Gwak, Joo-Yong Kim, Sung-Yub Jin
    Journal of the Korean Fracture Society.2013; 26(4): 248.     CrossRef
  • 99 View
  • 0 Download
  • 3 Crossref
Close layer
Case Reports
Posterior Hip Dislocation with Ipsilateral Fractures of the Femoral Head and Intertrochanter: A Case Report
Jai Hyung Park, Hyung Soo Kim, Soo Tae Chung, eong Hyun Yoo, Joo Hak Kim, Seung Do Cha, Tae Woo Lee
J Korean Fract Soc 2010;23(1):113-117.   Published online January 31, 2010
DOI: https://doi.org/10.12671/jkfs.2010.23.1.113
AbstractAbstract PDF
High-energy injury, as traffic accident or fall down, can cause fracture of femur head and posterior dislocation of hip joint which is accompanied with ipsilateral acetabulum fracture or femur neck fracture. But the case that femur head fracture and posterior dislocation of the hip joint coincide with ipsilateral intertrochanteric fracture of proximal femur is so uncommon that reports of the case is very rare. We hereby are to report the experienced and treated-cases of femur head fracture and posterior dislocation of the hip joint that is accompanied with ipsilateral intertrochanteric fracture.

Citations

Citations to this article as recorded by  
  • Decoding the behaviour of extracapsular proximal femur fracture- dislocation - A systematic review of a rare fracture pattern
    Keyur B. Desai
    Journal of Clinical Orthopaedics and Trauma.2021; 18: 157.     CrossRef
  • 126 View
  • 1 Download
  • 1 Crossref
Close layer
Combined Lunate and Triquetrum Fracture: A Case Report
Joo Hak Kim, Hyung Soo Kim, Soo Tae Chung, Jeong Hyun Yoo, Seung Do Cha, Joong Hyo Lee, Jai Hyung Park
J Korean Fract Soc 2008;21(4):320-324.   Published online October 31, 2008
DOI: https://doi.org/10.12671/jkfs.2008.21.4.320
AbstractAbstract PDF
We described an unusual case of a 16-year-old Taekwondo athlete who injured the left wrist when she compete with other athlete. She described a mechanism of axial loading, with the wrist in radial deviation. This unusual combined lunate and triquetrum fracture was not associated with the perilunar dislocation. We present this case with a review of the literature. In this case, internal fixation and early range of motion result in a good functional outcome.
  • 92 View
  • 0 Download
Close layer
Original Articles
Treatment with Modified Steinmann Pins and Tension Band Wiring Technique in Proximal Humeral Comminuted Fractures with Osteoporosis
Soo Tai Chung, Joo Hak Kim, Hyung Soo Kim, Sang Joon Park
J Korean Fract Soc 2007;20(2):184-189.   Published online April 30, 2007
DOI: https://doi.org/10.12671/jkfs.2007.20.2.184
AbstractAbstract PDF
PURPOSE
To evaluate the usefulness of internal fixation with modified Steinmann pins and tension band wiring technique in comminuted proximal humeral fracture with osteoporosis and the correlations among bone mineral density, age, Neer's score and period of union.
MATERIALS AND METHODS
Twelve cases of comminuted proximal humeral fracture with osteoporosis were surgically treated with modified Steinmann pins and tension band technique, and followed up for an average 20.8 months (range, 6~39 months). Average age was 73.6 years old (range, 59~85 years old). Results were assessed using Neer's evaluation criteria.
RESULTS
Excellent results were noted in eight cases and satisfactory results in four cases. Radiological union was obtained in all cases. Two cases showed impingement syndrome of the proximal portions of Steinmann pins, which were managed by early removal of the metal. One case developed operative wound infection, which were managed by antibiotics therapy, irrigation and secondary closure.
CONCLUSION
Internal fixation using modified Steinmann pins and tension band wiring technique for proximal humeral fracture, with osteoporosis, makes complete union of fracture, minimizes risk of complications, and enables early rehabilitation by rendering relatively rigid fixation.
  • 93 View
  • 1 Download
Close layer
The use of partridge cerclene system for the treatment of femurshaft fracture during and after the replacement arthroplasty of the hip 6 cases report
Hyung Soo Kim, Jeong Gook Seo, Jin Hyok Kim, Byung Jik Kim
J Korean Soc Fract 1991;4(2):312-319.   Published online November 30, 1991
DOI: https://doi.org/10.12671/jksf.1991.4.2.312
AbstractAbstract PDF
No abstract available.
  • 98 View
  • 0 Download
Close layer

J Musculoskelet Trauma : Journal of Musculoskeletal Trauma
Close layer
TOP