Shoulder dislocation is the most common dislocation presenting to the emergency department. In old age, the attempt of closed reduction is made with caution in order to prevent iatrogenic fracture around the shoulder. We report two cases of iatrogenic fractures of humeral shaft and anatomical neck in female patients older than 70 years old, which occurred during the manual closed reduction. One patient was proved as first-time and the other was recurrent. In addition, the second case had a massive irreparable rotator cuff tear. Those patients were treated successfully with humeral nailing and reverse total shoulder arthroplasty, respectively.
A fracture of the humeral shaft can occur by direct or indirect injury. Most occur as a result of direct injury mechanisms such as falls from a height, direct blows, and traffic accidents. Recently, the population enjoying watersports for leisure is increasing and 'flyfish riding', in which passengers ride an inflatable raft drawn by a motorboat, may cause humeral shaft fracture as twisting and axial compression forces occur on the humeral shaft while boarding. Accordingly, the incidence of humeral shaft fracture is expected to increase as more people are expected to enjoy leisure sport activities such as 'flyfish riding'. We report 4 cases of humeral fracture that occurred during this activity in the year 2011.
Citations
Citations to this article as recorded by
Humerus Shaft Fractures Occurring in Fly Fishing Boat Riding: Injury Scene Analysis Hongri Li, Wan Sun Choi, Bong-gun Lee, Jae-hoo Lee, Younguk Park, Doohyung Lee The Korean Journal of Sports Medicine.2019; 37(4): 134. CrossRef
PURPOSE This study is a retrospective analysis of patients who had undergone surgical treatment for non-union of distal humerus fracture. We evaluated them in terms of causes of injury, radiologic findings, and clinical outcomes such as prognosis. MATERIALS AND METHODS Seven consecutive radiologic patients who were confirmed to have nonunion of a distal humerus fracture underwent reoperations. These patients had already undergone operations for distal humerus fractures. This survey was held from 2005 to 2010. The average period up to diagnosis of non-union after the first operation was 7.4 months (4 to 16 months). The mean follow-up period was 24.6 months (12 to 65 months). Each patient was graded functionally according to the Mayo Elbow Performance Score and the Disabilities of the Arm, Shoulder and Hand Score. RESULTS Osteosynthesis was performed by internal fixation with plates and screws and then a bone graft for non-union of the distal humerus fracture. The average range of motion within the elbow joints was found to be a flexion contracture of 18.8 degrees (0~30 degrees) and further flexion of 120.2 degrees (102~140 degrees). Among postoperative complications, three cases of medium-degree stiffness, two cases of medial column nonunion, and one case of dissociation of the internal fixator were reported. CONCLUSION Stable internal fixation for maintenance reduction status is essential after accurate initial anatomical reduction. We concluded that nonunion could be prevented by additional surgical treatment such as autogenous bone graft, if it is necessary.
Citations
Citations to this article as recorded by
Autogenous Inlay Bone Graft for Distal Humerus Nonunion with Metaphyseal Bone Defect: A Technical Note Yong-Suk Lee, Dongmin Kim, Min-Sung Kang, Jong-Hwa Park, Sang-Uk Lee Archives of Hand and Microsurgery.2020; 25(1): 39. CrossRef
Periprosthetic fracture following a proximal humeral intramedullary (IM) nailing is rarely reported neither for its occurrence nor for its treatment. Proximal humeral IM nail (Acumed, LLC, Hillsboro, OR, USA) has been increasingly reported of its successful treatment outcomes, yet there is paucity of data describing its complications. Here we report a 26 year-old female patient, who sustained a proximal humerus fracture which was initially successfully treated by proximal humeral IM nail, and was complicated by a periprosthetic fracture distal to the nail tip at postoperative 4 months. Serial application of U-shaped coaptation splint, hanging cast, and functional bracing resulted in satisfactory clinical outcome. Periprosthetic fracture after proximal humerus IM nail can occur by a low energy injury, which need to reminded in treating young and sports-active patients.
Citations
Citations to this article as recorded by
Locking compression plate fixation of periprosthetic distant humeral fracture after intramedullary nail for humeral shaft fracture: A case report Mei-Ren Zhang, Kui Zhao, Jiang-Long Guo, Hai-Yun Chen Trauma Case Reports.2022; 37: 100565. CrossRef
Distal Humeral Fixation of an Intramedullary Nail Periprosthetic Fracture Hiren M. Divecha, Hans A. J. Marynissen Case Reports in Orthopedics.2013; 2013: 1. CrossRef
PURPOSE Authors compare clinical and radiological results of internal fixation group and hemiarthroplasty group for comminuted proximal humerus fracture to find out which the treatment method have to be chose for comminuted proximal humerus fractures. MATERIALS AND METHODS Patients who were treated from March 2005 to March 2007 and available for 2 years follow-up were targets of this study. The internal fixation group had 38 cases, and hemiarthroplasty group included 26 cases. The results were analyzed both clinically and radiologically. RESULTS On average, Bone union took 15.6 weeks in the internal fixation group. Constant score between the internal fixation and hemiarthroplasty groups were on average 75+/-6.5 points and 70+/-7.4 points (p=0.034). In 3-part fracture, Constant score between both groups were 78+/-5.4 points from the former and 71+/-2 points, respectively (p=0.028). In 4-part fracture group, Constant score were 72+/-8 points for the internal fixation group and 69+/-9.2 points for the hemiarthroplasty group (p=0.041). CONCLUSION Internal plate fixation can gain better outcome than hemiarthroplasty in 4-part fracture as well as 3-part fracture of proximal humerus by careful dissection for preservation of blood supply for humeral head and optimal reduction.
Citations
Citations to this article as recorded by
Surgical treatment of proximal humerus fractures: a systematic review and meta-analysis Erik Hohmann, Natalie Keough, Vaida Glatt, Kevin Tetsworth European Journal of Orthopaedic Surgery & Traumatology.2022; 33(6): 2215. CrossRef
Effectiveness and Safety of Interventions for Treating Adults with Displaced Proximal Humeral Fracture: A Network Meta-Analysis and Systematic Review Long Chen, Fei Xing, Zhou Xiang, Ara Nazarian PLOS ONE.2016; 11(11): e0166801. CrossRef
Meta-analysis comparing locking plate fixation with hemiarthroplasty for complex proximal humeral fractures Jiezhi Dai, Yimin Chai, Chunyang Wang, Gen Wen European Journal of Orthopaedic Surgery & Traumatology.2014; 24(3): 305. CrossRef
For valgus impacted four part fracture of the proximal humerus, surgical stabilization and early mobilization of the joint can produce the best clinical outcomes. But, we have experienced a case of conservative treatment and gained good clinical results. We have reported this case and included a review of the relevant literatures.
PURPOSE The purpose of this study was to review the outcome of fixation of distal humerus fractures using recently-introduced double parallel plate system in sagittal plane. MATERIALS AND METHODS From May 2004 to June 2008, seventeen patients with distal humerus fractures underwent primary open reduction and internal fixation with double parallel plates. According to the AO classification, there were 2 A3, 2 C1, 7 C2, and 6 C3 type fractures. Outcome assessment was performed by using the Mayo Elbow Performance index (MEPI). RESULTS At a mean follow up of 18 (range, 12 to 32) months, 4 patients were rated as excellent, 8 as good, and 5 as fair in terms of MEPI. The average arc of elbow flexion after primary operation was 116 (range, 90~140) degrees with a mean flexion contracture of 13 (range, 0 to 30) degrees. One patient required reoperation due to fixation failure and six patients underwent capsulolysis and three patients underwent ulnar nerve neurolysis. The time to begin elbow motion exercise had negative correlation with total elbow range of motion and multiple trauma patients had significantly lower MEPI functional score compared to those without combined injury. CONCLUSION Double parallel plating allowed adequate fixation for distal humerus fractures regardless of patient age and fracture pattern. Partial ankylosis and unlar nerve compression symptoms were the main causes of reoperation.
PURPOSE To evaluate the outcome of hemiarthroplasty with bone block graft and low profile prosthesis (Aequalis(R) fracture prosthesis) for the comminuted proximal humerus fractures. MATERIALS AND METHODS Sixteen low profile prostheses were used since July 2004, and 11 patients were followed-up for average 19.9 (12~30) months. Their mean age was 67.3 (52~78) years. Pain and satisfaction visual analog scale (VAS), range of motion, and modified UCLA score for hemiarthroplasty were evaluated at every visit. Radiography was also checked for stem position, loosening, and tuberosity union. RESULTS Mean pain VAS was 2.7 (0~5), and mean satisfaction VAS was 8.4 (5~10). Mean active forward flexion was 137 degrees (90~170), external rotation at side was 45.5 degrees (25~70), and internal rotation at back was T10 (T7~L1). Modified UCLA score was 19 (12~30) at final visit. All stems were stable, and there were no loosening at the final follow-up. All tuberosities were united except two tuberosity absorptions. CONCLUSION The outcome of hemiarthroplasty with bone block graft and low profile prosthesis was comparable to other implants for comminuted proximal humerus fractures. This system had unique advantages for tuberosity union. Further study with more patients and longer follow-up are necessary to clarify the effectiveness of this prosthesis.
Citations
Citations to this article as recorded by
A Separate Approach and Cephalo-Diaphyseal Plate Fixation for the Comminuted Metadiaphyseal Fractures of the Proximal Humerus Sung-Weon Jung Journal of the Korean Fracture Society.2013; 26(1): 8. CrossRef
Comparison of Results between Internal Plate Fixation and Hemiarthroplasty in Comminuted Proximal Humerus Fracture Doo-Sup Kim, Dong-Kyu Lee, Chang-Ho Yi, Jang-Hee Park, Jung-Ho Rah Journal of the Korean Fracture Society.2011; 24(2): 144. CrossRef
PURPOSE To evaluate the results of internal fixation with bifurcate angled blade plate and tension band wiring of greater tuberosity or rotator cuff for the unstable proximal humerus fracture. MATERIALS AND METHODS Nineteen cases of unstable proximal humerus fracture who were followed up for more than 1 year were treated using bifurcate angled blade plate and tension band wiring between March 2003 and March 2005. Average age of the patients was 46.5 years (range, 24 to 69), and there were 9 male and 10 female patients. The radiological results were evaluated by bony union and neck shaft angle. In addition, the clinical results were evaluated by Neer's evaluation criteria. RESULTS In 18 out of 19 cases, bony union was obtained in average 12.5 weeks after operation. The neck shaft angles of sixteen cases were between 120 and 140 degrees by Paavolainen method. According to Neer's evaluation criteria, 17 cases showed excellent or good results. CONCLUSION The patients treated using bifurcate angled blade plate and tension band wiring could exercise earlier because of good initial stability. Also, the radiological and clinical results were relatively good. The treatment of unstable proximal humerus fracture with bifurcate angled blade plate and tension band wiring was considered as a good method.
Citations
Citations to this article as recorded by
Hemiarthoplasty with Bone Block Graft and Low Profile Prosthesis for the Comminuted Proximal Humerus Fractures Chung Hee Oh, Joo Han Oh, Sae Hoon Kim, Ki Hyun Jo, Sung Woo Bin, Hyun Sik Gong Journal of the Korean Fracture Society.2008; 21(3): 213. CrossRef
PURPOSE The purpose of this study was to determine the results of internal fixation with locking plate system for the unstable proximal humerus fracture. MATERIALS AND METHODS Sixteen cases of unstable proximal humerus fracture were treated using locking plate system between September 2004 and June 2005. Average age of the patients was 55.6 years (range, 22 to 78), male was four patients, female was twelve. The clinical outcomes were evaluated by using Neer's evaluation criteria and Constant socring system. We analyzed the radiological results by bony union time and Paavolainen method. All data was analyzed statistically. RESULTS According to Neer's evaluation ciriteria, eleven cases (69%) showed excellent or satisfactory results and according to Constant scoring system, twelve cases (75%) showed excellent or good result. Twelve cases (75%) showed good results by Paavolainen method. In all cases, bony union was obtained in average 12.8 weeks after operation. There were two complications; one screw irritation and one screw loosing. CONCLUSION The patients treated using locking proximal humerus plate could exercise earlier due to good initial stability. And the clinical and radiological results were relatively good. The treatment of unstable proximal humerus fracture with locking plate system was considered as a good method.
Citations
Citations to this article as recorded by
Open Intramedullary Nail with Tension Band Sutures & Lock Sutures on Proximal Humeral Three-part Fracture Jin-Oh Park, Jin-Young Park, Sung-Tae Lee, Hong-Keun Park Journal of the Korean Fracture Society.2007; 20(1): 45. CrossRef
PURPOSE To evaluate the causative factors in the catastrophic failure of LCP in the proximal humerus fracture. MATERIALS AND METHODS Six patients (6 cases) were collected between October 2003 and July 2005. The mean age was 55.6 years (range: 38~70). The cause of injury was road traffic accident in four, fall down in one and slip down in one. According to the Neer classification, four were 2 part fractures, each one in 3 part fracture and 4 part fracture. RESULTS Fixation failure occurred due to back-out of the plate and screw in five and plate breakage in one. Analysis of the preoperative radiographs revealed medial cortical defect in all and no bone graft and tension band wiring in the greater tuberosity fragment were carried out. Postoperative radiographs showed the anatomical reduction in three and non-anatomical in three. CONCLUSION Non-anatomical reduction, insufficient medial bony buttress, inadequate screw length to the head and the neglect for the greater tuberosity fragment were the contributing factors to the failure of LCP. Knowledge of these factors will enable the surgeon to avoid failure of the LCP. Augmentation fixation and bone graft procedures with careful preoperative planning are necessary for successful fixation of LCP.
Citations
Citations to this article as recorded by
The Result of Conservative Treatment of Proximal Humerus Fracture in Elderly Patients Seung-Gil Baek, Chang-Wug Oh, Young-Soo Byun, Jong-Keon Oh, Joon-Woo Kim, Jong-Pil Yoon, Hyun-Joo Lee, Hyung-Sub Kim Journal of the Korean Fracture Society.2013; 26(4): 292. CrossRef
A Separate Approach and Cephalo-Diaphyseal Plate Fixation for the Comminuted Metadiaphyseal Fractures of the Proximal Humerus Sung-Weon Jung Journal of the Korean Fracture Society.2013; 26(1): 8. CrossRef
Internal Fixation of Proximal Humerus Fracture with Polyaxial Angular Stable Locking Compression Plate in Patients Older Than 65 Years Ki Won Lee, Young Joon Choi, Hyung Sun Ahn, Chung Hwan Kim, Jae Kwang Hwang, Jeong Ho Kang, Han Ho Choo, Jun Seok Park, Tae Kyung Kim Clinics in Shoulder and Elbow.2012; 15(1): 25. CrossRef
Open Intramedullary Nail with Tension Band Sutures & Lock Sutures on Proximal Humeral Three-part Fracture Jin-Oh Park, Jin-Young Park, Sung-Tae Lee, Hong-Keun Park Journal of the Korean Fracture Society.2007; 20(1): 45. CrossRef
We report an unusual case of Kirschner wire migration from the proximal humerus into the thoracic cavity and diaphragm which induced pneumothorax and hemoperitoneum. An 81-year-old woman admitted to the emergency room due to sudden onset of dyspnea. X-rays showed pneumothorax and old proximal humerus fracture fixed with rush pins and K-wires. One of K-wires was seen on the diaphragm level at posterior gutter of chest wall. Through the abdomen, K-wire was removed from the diaphragm and a chest tube was inserted. The potential for K-wires to migrate must be recognized, and frequent postoperative radiographic studies have to be performed for the early detection of loosening and migration. It appears that if K-wires are used for fixation of proximal humerus, the lateral ends must be bent to prevent medial migration, and when the desired therapeutic goals have been achieved, these pins have to be susbsequently removed as soon as possible.
Citations
Citations to this article as recorded by
Spinal Canal Migration of a K-Wire Used for Fixation of a Distal Clavicular Fracture Byung-Ill Lee, Yong-Beom Kim, Hyung-Suk Choi, Chang-Hyun Kim, Jung-Woo Ji Journal of the Korean Orthopaedic Association.2013; 48(3): 231. CrossRef
Early Intrathoracic Migration of K-wire Used for Fixation of Proximal Humerus Fracture Sang Jin Cheon, Ji Min Lee Journal of the Korean Orthopaedic Association.2011; 46(2): 167. CrossRef
PURPOSE To study the development of inferior shoulder subluxation after surgery for proximal humerus fractures. To analyze the mechanism development of such subluxation and the association between different types of proximal humerus fractures, quality of reduction achieved the method of operation performed. MATERIALS AND METHODS A retrospective analysis of 45 proximal humerus fractures that were treated by surgery between March 1997 and July 2002 was done. All patients had a minimum of 12 months of postoperative follow up. Preoperative radiographs were classified by the Neer's classification. Different operative treatment methods, post reduction alignment and the degree of postoperative subluxation if present, were analysed. In order to evaluate effect of loss of negative intraarticular pressure, we compared this series with 15 cases of recurrent shoulder dislocation treated by open Bankart operation. RESULTS 13 patients out of 45 (29%) developed immediate postoperative inferior shoulder subluxation. 3-part fractures of the proximal humerus showed a higher incidence of the same than the 2-part types. The better reduced fractures had lesser rates of subluxation. Open reduction (39%, 11 patients) results in an increased incidence of inferior subluxation than closed methods of reduction (13%, 2 patients). CONCLUSION Inferior subluxation of the humeral head after surgery for the proximal humerus fracture can occur and persist till postoperative period of 2 months. Deltoid muscle tone affected by shortening of humeral neck plays an important role. Early active exercise for restoration deltoid tone may be effective in prevention of inferior subluxation.
Citations
Citations to this article as recorded by
Transient postoperative inferior subluxation of the shoulder after surgical stabilization of recurrent anterior dislocation in a patient with myasthenia gravis: a case report Samuel Baek, Geum-Ho Lee, Myung Ho Shin, Tae Min Kim, Kyung-Soo Oh, Seok Won Chung Clinics in Shoulder and Elbow.2023; 26(3): 302. CrossRef
PURPOSE To evaluate the clinical results of this modified anatomical Y-plate in treatment of distal humerus fracture and factors that affect the results. MATERIALS AND METHODS From April 1991 to January 2002, 40 cases (16 male, 24 female) of distal humeral fractures were treated using a modified anatomical Y plate. The patient's age, gender, pain, range of motion, instability, function, bone union, and complication were recorded. RESULTS At the operation, the mean age of patients is 49.5 years (12~74 years) and mean follow up period is 18 months (13~82 months). In the range of motion, mean flexion is 122.1 degrees (75~140 degrees) and mean flexion contracture is 11.4 degrees (0~30 degrees). Results by Morrey's functional evaluation include 15 excellent, 23 good and 2 fair cases. There are 2 excellent and 5 good cases in patients of supracondylar fracture which didn't involve the articular surface (A2, A3 type of AO classification), and 13 excellent, 18 good and 2 fair cases in patients of intracondylar fracture which involve the articular surface (B2, C1, C2, C3 type). But there is no statistical significance in results between two groups. There are 3 excellent, 3 good cases in 6 open fracture and 2 excellent, 6 good and 1 fair case in 9 patients with multiple trauma. The patient's age, gender, open fracture, multiple trauma, and intraarticular fracture did not affect the results. CONCLUSION Satisfactory results can be obtained if the modified anatomical Y-plate is used to treat a distal humerus fracture, regardless of many factors affecting the results.
Citations
Citations to this article as recorded by
Comparative study of a Y- anatomical and innovative locking plate versus double plate for supracondylar humeral fracture Hugo Barret, Romain Ceccarelli, Paul Vial D’Allais, Matthias Winter, Michel Chammas, Bertrand Coulet, Cyril Lazerges Orthopaedics & Traumatology: Surgery & Research.2023; 109(5): 103380. CrossRef
Étude comparative d’une plaque verrouillée anatomique et innovante en Y par rapport à 2 plaques à 90 degrés pour la prise en charge des fractures supra condyliennes de l’humérus Hugo Barret, Romain Ceccarelli, Paul Vial d’Allais, Matthias Winter, Michel Chammas, Bertrand Coulet, Cyril Lazerges Revue de Chirurgie Orthopédique et Traumatologique.2023; 109(5): 648. CrossRef
Double Parallel Plates Fixation for Distal Humerus Fractures Young Hak Roh, Moon Sang Chung, Goo Hyun Baek, Young Ho Lee, Hyuk-Jin Lee, Joon Oh Lee, Kyu-Won Oh, Hyun Sik Gong Journal of the Korean Fracture Society.2010; 23(2): 194. CrossRef
PURPOSE This is a retrospective study to analyze the functional results of closed reduction and external fixation of unstable fractures of the proximal humerus. MATERIALS AND METHODS Ten unstable proximal humerus fractures were managed with closed reduction and external fixation in which other operative methods are not proper due to comminution, osteoporosis or poor general condition of patients. 4 cases of 2-part and 6 cases of 3-part fracture were included. Radiologically union of fracture, malunion and the evdence of avascular necrosis of humeral head were assessed and the functional results were analyzed with Neer scoring system. RESULTS Radiologically all fractures were healed but in 2 cases malunion was resulted because of reduction loss in proximal fragment. Pin site infection was developed in 7 cases and oral antibiotics were needed. The functional results were excellent in 4, satisfactory in 3 and unsatisfactory in 3 cases. 2 cases with malunion and one case with lack of postoperative cooperation resulted in functionally unsatisfactory. CONCLUSION External fixation is an alternative method in the treatment of unstable proximal humerus fractures in which open reduction or percutaneous pinning are not proper due to comminution, osteoporosis or poor general condition of patient.
PURPOSE : The purpose of this pater was to evaluate results of double plate osteosynthesis in distal humerus fractures.
MATERIAL AND METHOD : From June1995 to August 1998, we reviewed 22 distal humerus fractures. According to the type of fractures(AO classification), 6 and 16 cases were type A and C respectively. According to surgical approach, transolecranon approach was done in 12 cases and triceps split approach in 10 cases. We fixed intercondylar fracture with lag screw and supracondylar fracture with dual plate(2 reconstruction plates or 1 reconstruction plate + 1/3 tubular plate) as right angle. Rehabilitation was started just after postoperative 24 hours with posterior splint, and then increase activity and frequency. RESULTS : Average union time was 11.5 weeks. Overall functional results according to the classification of Jupiter and Cassebaum were excellent, good, fair, poor in 8, 10, 3, 1 cases, respectively. According to the age, patients under 50-year-old group revealed slightly superior functional. According to the type of fracture, surgical approach, interval between injury and approach, there were no statistically significant difference between group(p>0.05). There were 5 cases with complications. 1 case was mental failure, 3 cases were ulnar palsy, and 1 case was transient radial nerve palsy. CONCLUSION : We consider dual plate osteosynthesis in distal humerus fractures as a good treatment modality, even in type C fractures and old age patients.
From retrospective review of 26 humerus fractures treated by Seidel interlocking intramedullary nailing, 17 complications in nine patients(35%) were occurred: two delayed unions, three malunions, two infections, one distraction of fracture gap, two additional fragmentations, two failures in proximal interlocking screw insertion, three distal locking mechanism failures and two proximal protrusions of nail. Functional assessment was carried out an all patients at a mean follow up 13 months(9-23 months). The results were ten excellent, twelve good, two fair and two poor. These results show that there are considerable problems at present in the use of the seidel interlocking nail.
Proximal humerus fracture with epiphyseal plate injury does not cause the growth disturbances and deformity of humerus in comparison with other fracture of epjphyseal plate. The explanation about this phenomenon is that the fracture occurs microscopically in maturing Bone near provisional calcifying zone, another explanation is that the epiphyseal plate in proximal humerus greatly contribute the longitudinal growth of humerus and has trimendous remodelling potential. In this study, we experienced the 25 cases of proximal humeral epiphyseal injury from January, 1991 to June, 1997 We analyzed the growth disturbance and deformity of the proximal humeral epiphyseal plate in regard to age, fracture type, treatment method of the 15 cases with 3 years follow-up among the 25 cases. This fracture is most common in the age of 13 to 16, 11 cases among total 15 cases(75 percent). Most common fracture type is type II by Salter-Harris classification, 14 cases among total 15 cases, 3 cases is type IV by Neer-Horowitz classification, where, manual reduction was impossible because of interposition with biceps tendon between fracture fragments. There was no impairment of motion, growth distrubance and deformity in all cases. We concluded there is no direct correlation with patient age, the degree of fracture, displacement, treatment method in view of gorwth disurbance and deformity.
There is no consensus on the best way to treat complicated fractures of the proximal humerus. Open reduction and internal fixation with plate is one of the most popular method, but it has several disadvantages. Thus we used bent semitubular plates to fix the proximal humeral fractures, which were reported by Szabo and Sehr. Moda etc.
This method provided relatively firm fixation and then early ROM exercise was possible even in case of osteoporotic or severely comminuted fractures.
We treated 9 cases of proximal humerus fractures which were with bent semitubular plates from January 1992 to June 1996 and followed up more than 6 months.
The following results were obtained.
1. The bent semitubular piate fixation was useful method even in treatment of comminuted or osteoporotic proximal humerus fractures.
2. The mean duration of radiologic bone union was postoperative 10 weeks.
3, Complications developed in 2 cases ; one case was plate failure and the other was humeral head penetration by blade portion.
4, According to Neer criteria 5 cases were excellent, 2 cases satisfactory, 1 case unsatisfactory and 1 case failure.
Fracture of the proximal humerus occurs more frequently in older individuals who may have advancing osteoporosis, causing the bone to weaken, even with minimal force. And, most proximal humeral fractures respond satisfactory to conservative treatment. But, operative treatment is reconmended in the case that poor results are anticipated by the severe displacement and comminution. In older patient with proximal humerus fracture, there was some problem such as osteoporosis, absorption of cancellous bone, cystic formation, and weakness of the mechanical support, and it has difficulties in rigid fixation and early ROM. Four cases of displaced fracture of the proximal humerus in older patients over 50-year-old Treated by using plate & inlay fibular allograft from Apr. 1991 to Dec. 1993 were analized clinically and radiologically.
The following results were obtained.
1. The results of these patients were rated by the Neers functional criteria. Of four cases, three cases had excellent results, one case had satisfactory.
2. There was no allograft related complications, such as infection & graft rejection.
So, in treatment of proximal humerus fracture at old individuals, open reduction and internal fixation with plating and inlay graft using fibular allograft was very useful method, and it resulted in rigid fixation, early ROM. and good functional result.
Citations
Citations to this article as recorded by
Allogeneic Inlay Cortical Strut Grafts for Large Cysts or Post-curettage Cavitary Bony Defects Yang-Guk Chung, Yong-Koo Kang, Chol-Jin Kim, An-Hi Lee, Jeong-Mi Park, Won-Jong Bahk, Hyun-Ho Yoo The Journal of the Korean Bone and Joint Tumor Society.2011; 17(2): 73. CrossRef
Closed reduction and percutaneous pinning of displaced supracondylar fractures of the humerus in children yielded simple fracture management, less neurological and vascular complications, reduced hospitalization day and increased satisfactory out-comes. We treated twenty-seven cases of these fractures(extension type : twenty-five cases) by such a method.
The accurate closed reduction of a supracondylar fracture could be obtained and confirmed by image intensifier. The maintanence of a reduction was stabilized by application of K-wires.
Our study showed that the limitation of range of motion of the elbow joint was not signifiint(three cases, below ten degrees extension block and changes of carrying angle was also minimal three cases, below ten degrees).
In twenty-seven cases, excellent results were recorded in 93% on at least on year follow-up.
The term "floating elbow" refers to concomitant ipsilateral humeral and forearm bone fractures. This type of fractures is relatively rare and has few guidelines for treatment.
Author reviewed 14 cases of these fractures which were treated by open reduction and rigid internal fixation in Pusan National University Hospital from January 1983 to January 1993.
In follow up study, Author obtained that good results in 10 cases(71%) of patient, and fair results in 3 cases of patient.
Author advocate the patient with concomitant ipsilateral humerus and forearm bone fractures should requires open reduction and stable internal fixation of the both humerus and forearm bone, as soon as possible.
Comminuted fractures of the distal end of the humerus in adult are notoriously difficult to treat, and had reported many problems. Because anatomical structure around the olecranon fossa was composed by weak trabecular bone, accurate anatomical reduction and rigid fixation of the fracture fragment was not easily achieved by ordinary concept and implants. Recently, various anatomical plates for the fractures of the metaphyseal area of long bone were developed and relatively good results were reported. The authors developed new anatomical plate for distal humerus which had an well adaptable and more malleable characteristics for the fracture of the distal humerus. We report our short experience, of 3 cases treated with this plate.