Distal tibial metaphyseal fractures are commonly caused by high-energy injuries in young men and osteoporosis in older women. These fractures should be clearly distinguished from high-energy pilon fractures. Although the optimal surgical intervention methods for distal tibial metaphyseal fractures remain uncertain and challenging, surgical treatments for nonarticular distal tibia fractures can be broadly divided into two types: plate fixation and intramedullary nail (IMN) fixation. Once functional reduction is achieved using an appropriate technique, distal tibial nailing might be slightly superior to plate fixation in reducing postoperative complications. Thus, the surgical strategy should focus on functional realignment and proceed in the following sequence: (1) restoring the original tibial length, regardless of whether fibular fixation is to be done; (2) making the optimal entry point through an anteroposterior (AP) projection based on the overlapping point between the fibular tip and lateral plateau margin; (3) placing Kirschner wires (Ø2.4 mm) as blocking pins (in the AP orientation for coronal control and in the mediolateral [ML] orientation for sagittal control) as close to the upper locking hole as possible without causing further comminution on the concave aspect of the short fragment; and (4) making the the distal fixation construct with at least two ML and one AP interlocking screw or two ML interlocking screws and blocking screws. After the IMN is adequately locked, blocking pins (Ø2.4 mm) need to be replaced by a 3.5 mm screw.
Purpose This study examined the structural and mechanical stability as well as the clinical significance of various fixation constructs for distal tibial fractures using finite element analysis. Materials and Methods Fracture models with 20 mm and 120 mm defects were produced, and implants of an intramedullary nail and anatomical plate model were applied. An axial load of 800 N with 60% distribution in the medial compartment and 40% in the lateral compartment was applied and analyzed using Ansys ® software. Results In the intramedullary nail model, the maximum von Mises stress occurred at the primary lag screw hole and adjacent medial cortex, while in the plate model, it occurred at the locking holes around the fracture. The maximum shear stress on the bone and metal implant in the fracture model with a 20 mm defect was highest in the plate assembly model, and in the fracture model with a 120 mm defect, it was highest in the two-lag screw assembly model. Conclusion Based on an analysis of the maximum shear stress distribution, securing the fixation strength of the primary lag screw hole is crucial, and the assembly model of the intramedullary nail with two lag screws and a blocking screw applied was the model that best withstood the optimal load. Securing the locking hole directly above the fracture is believed to provide the maximum fixation strength because the maximum pressure in the plate model is concentrated in the proximal locking hole and the surrounding cortex.
Purpose This study examined the results of internal fixation using an intramedullary nail in the treatment of distal metaphyseal fractures involving the articular surface. Materials and Methods From November 2009 to November 2018, distal tibia fractures involving the articular surface were treated with intramedullary nailing only for fractures corresponding to AO type 43 B and 43 C1, twenty-four cases were studied retrospectively. The tibial alignment was measured preoperatively and postoperatively, and the bone union time and nonunion were assessed. In addition, the clinical evaluation of ankle joint function was assessed using the Olerud and Molander ankle score (OMAS). Results Complete bone union was obtained in all cases, and the mean union time was 17.7±1.87 weeks (range, 15-20 weeks). The average preoperative coronal alignment was 6.4°±1.0° (range, 5.2°-8.4°), and sagittal alignment was 2.7°±0.6° (range, 1.9°-3.8°). The average postoperative coronal alignment was 2.5°±0.13° (range, 2.2°-2.6°) and sagittal alignment was 0.4°±0.25° (range, 0.09°-0.95°). There was no nonunion. The OMAS had an average of 85±7.9 points (range, 70-95 points). Conclusion In the treatment of distal metaphyseal fractures involving the articular surface, internal fixation using an intramedullary nail reduces complications and achieves satisfactory reduction and union.
This method is considered an excellent treatment to obtain good clinical results.
Purpose Distal tibia fractures with severe soft-tissue edema or intra-articular fractures are treated by staged operations using external fixators. Definitive surgery that maintains ligamentotaxis has been difficult using existing fixators. This study introduced a novel ‘box-frame’ external fixator and evaluated its clinical usefulness. Materials and Methods This study included 45 patients (32 males, 13 females) diagnosed with distal tibia fractures who underwent staged operations between March 2012 and March 2016, with a follow-up of at least one year. The patients were divided into two groups. In one group, fixation was performed with a box-frame external fixator (Group A). In the other group, fixation was performed with a delta-frame external fixator (Group B). The following outcomes were evaluated: the time until definitive surgery, operative time of the definitive surgery, radiation exposure time, bone union, time to achieve bone union, postsurgical complications, American Orthopaedic Foot & Ankle Society anklehindfoot score, and ankle range of motion. Results Compared to the delta-frame, the box-frame showed a statistically significant reduction in the mean radiation-exposure time and operative time during the definitive surgery by 58 seconds and 25 minutes, respectively. The differences in the time until definitive surgery, bone union, time to achieve bone union, postsurgical complications, and functional scores were not significant. Conclusion The box-frame external fixator can be a useful treatment method in the staged surgery of distal tibia fractures.
Citations
Citations to this article as recorded by
Temporary Circular External Fixation for Spanning the Traumatized Ankle Joint Nando Ferreira, Niel Bruwer, Adriaan Jansen van Rensburg, Ernest Muserere, Shao-Ting Jerry Tsang JBJS Essential Surgical Techniques.2024;[Epub] CrossRef
Temporary circular external fixation for spanning the traumatised ankle joint: A cohort comparison study William D. Harrison, Franklin Fortuin, Matthieu Durand-Hill, Etienne Joubert, Nando Ferreira Injury.2022; 53(10): 3525. CrossRef
This paper reports a pseudoaneurysm of the anterior tibial artery after reduction with pointed bone reduction forceps on a spiral fracture of the distal tibia. Most reported injuries occurred at the proximal part of anterior tibial artery during drilling of the proximal tibia. To the best of the authors' knowledge, injury of the distal part of anterior tibial artery has never been reported. This paper describes a 54-year-old woman with a pseudoaneurysm of the anterior tibial artery clinically detected 11 weeks after the index surgery. This report highlights the need for surgeons to be aware of and careful about this complication during and after surgical intervention.
PURPOSE This study compared the radiological and clinical results of minimally invasive plate osteosynthesis (MIPO) and intramedullary nailing (IMN) of distal tibial fractures, which were classified as the simple intra-articular group and extra-articular group. MATERIALS AND METHODS Fifty patients with distal tibial fractures, who could be followed-up more than 12 months, were evaluated. Group A consisted of 19 patients treated with MIPO and group B consisted of 31 patients treated with IMN. The results of each group were analyzed by radiological and clinical assessments. RESULTS The mean operation times in groups A and B were 72.4 minutes and 65.7 minutes, respectively. The mean bone union times in groups A and B were 16.4 weeks and 15.7 weeks, respectively. The bone union rate in groups A and B were 100% and 93%, respectively. The ranges of ankle motion were similar in the two groups at the last follow-up. The mean American Orthopaedic Foot and Ankle Society score was similar: 90.1 in group A and 90.5 in group B. The radiological and clinical results were similar in the intra and extra-articular groups. In groups A and B, two cases of posterior angulation and five cases of valgus deformity of more than 5° were encountered. CONCLUSION Both MIPO and IMN achieved satisfactory results in extra-articular AO type A and simple articular extension type C1 and C2 distal tibia fractures.
Citations
Citations to this article as recorded by
Intramedullary Nailing versus Minimally Invasive Plate Osteosynthesis for Distal Tibia Shaft Fractures: Retrospective Comparison of Functional and Cosmetic Outcomes Kahyun Kim, In Hee Kim, Geon Jung Kim, SungJoon Lim, Ji Young Yoon, Jong Won Kim, Yong Min Kim Journal of Korean Foot and Ankle Society.2023; 27(3): 93. CrossRef
PURPOSE We evaluated the usefulness of an additional, 2.7 mm mini-locking plate for tibial pilon fractures. MATERIALS AND METHODS We studied 21 patients (14 males and 7 females), who were treated with a 2.7 mm mini-locking plate via the anterolateral approach for tibial pilon fractures between September 2012 and April 2014. The mean age was 43.85 years, and the mean follow-up period was 16.6 months. The radiologic outcomes were graded by the Burwell and Charnley modified system and clinical outcomes were evaluated by the American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hind foot score and visual analogue scale (VAS) score. RESULTS The mean union period was 14.3 weeks. At the final follow-up, radiologic results showed 16 excellent results, 4 fair results, and 1 poor result. The average VAS was 3.4 points; the average AOFAS score was 81.8 points. During the follow-up period, there were three cases of posttraumatic osteoarthritis and one case of superficial skin infection. CONCLUSION Additional anterolateral, 2.7 mm mini-locking plate may be a good treatment method to manage tibial pilon fractures.
PURPOSE The purpose of this study is to analyze the radiographic and clinical results of intramedullary nailing after percutaneous reduction using pointed reduction forceps for spiral or oblique fractures of the distal tibia. The benefit of percutaneous reduction using pointed reduction forceps in anatomical reduction and maintenance was assessed. MATERIALS AND METHODS From January 2005 to December 2009, 47 cases of distal one-third tibial fracture were managed by intramedullary nailing using pointed reduction forceps. Thirty-eight cases were spiral fracture and nine cases were oblique fracture. In all cases, the percutaneous reduction was achieved using pointed reduction forceps under fluoroscopy control. While maintaining the reduction with the pointed reduction forceps, the intramedullary nail was inserted. The pointed reduction forceps were removed after insertion of proximal and distal inter-locking screws. Alignment was evaluated with anterior-posterior and lateral radiographs taken immediately post-operation and at the time of union. RESULTS At immediate post-operation, the mean displacement of valgus and anterior angulation was 0.57degrees and 0.24degrees, respectively. That of valgus and anterior angulation at bone union was 0.37degrees and 0.16degrees, respectively. The average duration of bone union was 16.1 weeks. CONCLUSION Intramedullary nailing with percutaneous reduction using pointed reduction forceps for distal tibial fractures was an easy and effective method for achievement of accurate alignment intra-operatively. Accurate alignment was successfully maintained until bone union.
PURPOSE To evaluate the clinical and radiological results of minimally invasive plate, osteosynthesis, using either a locking compression plate-distal tibia (LCP-DT) or Zimmer periarticular locking plate (ZPLP) for distal tibia fractures. MATERIALS AND METHODS Fifty one patients (51 cases), who underwent minimally invasive osteosynthesis using locking compression plate for distal tibia fractures between October 2008 and August 2011, were followed for more than six months. Eighteen patients were treated with LCP-DT and 33 patients with ZPLP. Time to bony union and anatomic alignment were evaluated radiologically. Clinically, American Orthopedic Foot & Ankle Society ankle-hindfoot scales (AOFAS score) and range of ankle motion were assessed and compared between two groups. RESULTS All patients achieved bony union at an average of 18 weeks on LCP-DT group and 16weeks on ZPLP group. The average American Orthopedic Foot & Ankle Society ankle-hindfoot scales was 83.3 points on the LCP-DT group, 84.6 points on the ZPLP group, and range of ankle motion averaged at 45 degrees, 48 degrees, respectively. CONCLUSION Both types of locking compression plates were effective when performing minimally invasive osteosynthesis for distal tibia fractures.
Citations
Citations to this article as recorded by
Biomechanical analysis and clinical effects of bridge combined fixation system for femoral fractures Da-xing Wang, Ying Xiong, Hong Deng, Fu Jia, Shao Gu, Bai-lian Liu, Qun-hui Li, Qi Pu, Zhong-zi Zhang Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine.2014; 228(9): 899. CrossRef
PURPOSE To analyze the clinical results of operative treatment of distal tibia fracture with locking compression plate fixation through a minimally invasive percutaneous plate osteosynthesis technique. MATERIALS AND METHODS The subjects were 46 patients (conventional open surgery: 22 patients, minimally invasive percutaneous plate osteosynthesis: 24 patients) with fracture of the distal tibia who were treated with plating between November 2006 and June 2010. The time of bony union, complications, range of motion, and clinical functional outcome (according to American Orthopedic Foot and Ankle Society, AOFAS) were investigated. RESULTS In the minimally invasive percutaneous plate osteosynthesis group, the average union time was 14.3 weeks, postoperative range of motion was an average of 55.2, average AOFAS was 96.9, and incidence of complications was 20.8%. In the open surgery group, the average union time was 18.9 weeks, postoperative range of motion was an average of 49.1, average AOFAS was 83.8, and incidence of complications was 32.6%. There were statistically significant differences (p<0.05). CONCLUSION Surgical treatment with locking compression plate fixation through the minimally invasive percutaneous plate osteosynthesis technique showed favorable results regarding its union time, postoperative functional outcome, and incidence of complications. The locking compression plate fixation through minimally invasive percutaneous plate osteosynthesis technique can be an effective treatment option.
Citations
Citations to this article as recorded by
Minimally Invasive Plate Osteosynthesis for Fractures of Distal Tibia Tae Hun Kim, So Hak Chung Kosin Medical Journal.2014; 29(1): 23. CrossRef
PURPOSE To compare results between minimally invasive plate osteosynthesis using a periarticular plate and intramedullary nailing in distal tibial metaphyseal fractures in two treatment groups. MATERIALS AND METHODS Sixty-one cases of distal tibial metaphyseal fractures from December 2008 to December 2009 were evaluated. The minimal follow-up period was 12 months. Thirty patients treated by minimally invasive plate osteosynthesis using a periarticular plate were Group A; 31 patients treated by intramedullary nailing were Group B. We compared and analyzed the results of each group by radiological and clinical assessments. RESULTS The mean bony union time was 16.4 weeks in Group A and 17.2 weeks in Group B. The mean operation time was 45 minutes in Group A and 48 minutes in Group B. The mean radiation exposure times were 4.2 minutes and 4.8 minutes, respectively. VAS scores were 0.7 points and 0.5 points in each respective group. In Group A, the VAS score was 1.7 points when we applied pressure on the skin around the plate. The mean Olerud and Molander Ankle Score was 87.4 points and 86.3 points, respectively. A superficial wound infection occurred in 1 case in each group, and angular deformities more than 5 degrees occurred in 2 Group B cases. CONCLUSION No significant differences in results were observed between the two groups. However, a higher incidence of angular deformity was seen in the intramedullary nailing group. Therefore, we must be careful during surgery.
Citations
Citations to this article as recorded by
Comparative Analysis of Minimally Invasive Plate Osteosynthesis and Intramedullary Nailing in the Treatment of the Distal Tibia Fractures Ho-Min Lee, Young-Sung Kim, Jong-Pil Kim, Phil-Hyun Chung, Suk Kang, Kaung Suk Jo Journal of the Korean Fracture Society.2018; 31(3): 94. CrossRef
A Comparison of the Results between Intramedullary Nailing and Minimally Invasive Plate Osteosynthesis in Distal Tibia Fractures Chul-Hyun Park, Chi-Bum Choi, Bum-Jin Shim, Dong-Chul Lee, Oog-Jin Shon Journal of the Korean Orthopaedic Association.2014; 49(4): 285. CrossRef
PURPOSE To report the method of anatomical reduction and its maintenance by percutaneous wiring reduction in minimally invasive plate osteosynthesis for distal tibial fractures. MATERIALS AND METHODS 17 cases that were diagnosed oblique, spiral or transverse fracture of distal tibia from August 2007 to February 2010 and were able to anatomically reduce by the method of percutanous wiring reduction in minimally invasive plate osteosynthesis were included in this study. Mean age was 50, and mean follow up period was 18 months. We investigated the period until bone union was achieved, degree of angulation angle, and complications. For postoperative evaluation, Olerud and Molander ankle score and VAS pain score in daily living were checked. RESULTS The mean varus/valgus angulation after bone union on AP radiograph was 0.9 degrees and the mean anterior/posterior angulation on lateral radiograph was 2.0 degrees The mean Olerud and Molander ankle score was 89.4, and mean pain score due to walk adjacent to metal plate was 0 points. CONCLUSION By the method of percutaneous wiring reduction in distal tibial fracture, anatomical reduction is easily acquired, and only by wire itself, reduction could be maintained, so that without additional manual reduction, plate could be easily fixed.
PURPOSE To evaluate the factors influencing periosteal interposition in distal tibial physeal fractures of children. MATERIALS AND METHODS 34 cases of distal tibial physeal fractures were analysed. We confirmed the presence of periosteal interposition with MRI in all cases and accessed the relationship between periosteal interposition and gender, age, cause of injury, type of fracture, degree of initial displacement and after closed reduction. RESULTS 9 (26.5%) of 34 fractures had interposed periosteum. There was no statistically significant correlation between periosteal interposition and gender, age, cause of injury (p>0.05). 5 (83.3%) of 6 pronation-eversion-external rotation type of fractures according to Dias-Tachjian classification had interposed periosteum and that was a statistically significant correlation (p=0.006). As Salter-Harris type was toward to high degree, there were decreasing tendency of periosteal interposition (p=0.026). There was high rate of periosteal interposition in case of displacement more than 2 mm in each initial and after closed reduction (p<0.05). CONCLUSION There was high incidence of periosteal interposition in pronation-eversion-external rotation type with displacement more than 2 mm in distal tibial physeal fractures of children. But, periosteal interposition could occur in fractures with mild displacement less than 2 mm, if initial fracture displacement was more than 2 mm, the methods of treatment should be decided after confirm the presence of periosteal interposition with MRI after closed reduction.
PURPOSE To evaluate the outcome of minimally invasive osteosynthesis using locking compression plate for distal tibia fractures. MATERIALS AND METHODS Forty five patients (45 cases) who underwent minimally invasive osteosynthesis using locking compression plate for distal tibia fractures between January 2006 and June 2008, were followed for more than one year. The average duration of the follow-up was 30.5 months (12~54 months). The fracture types were as followed: 26 cases (58%) of extraarticular fractures, 19 cases (42%) of intraarticular fractures, and 16 cases (36%) of open fractures. RESULTS All patients achieved bone union at average of 21weeks (12~36 weeks). The average American Orthopedic Foot & Ankle Society ankle-hindfoot scales was 84.6 points (65~100 points) and range of ankle motion averaged at 46.5 degrees (20~60 degrees). Complications included 6 cases of superficial infection, 3 cases of malalignment and 5 cases of skin irritation by plate. There were no cases of deep infection, skin necrosis, shortening and metal breakage. CONCLUSION Minimally invasive osteosynthesis using locking compression plate for distal tibia fractures is considered to be an effective method with high healing rate, rapid functional recovery and low complication rate due to minimal disruption of bone and soft tissue biology and improved fixation strength.
Citations
Citations to this article as recorded by
Anterolateral Minimally Invasive Plate Osteosynthesis of Distal Tibial Fractures Using an Anterolateral Locking Plate Dongwhan Suh, Hwan Hee Lee, Young Hoon Han, Jae Jung Jeong Journal of Korean Foot and Ankle Society.2020; 24(1): 19. CrossRef
Comparative Analysis of Minimally Invasive Plate Osteosynthesis and Intramedullary Nailing in the Treatment of the Distal Tibia Fractures Ho-Min Lee, Young-Sung Kim, Jong-Pil Kim, Phil-Hyun Chung, Suk Kang, Kaung Suk Jo Journal of the Korean Fracture Society.2018; 31(3): 94. CrossRef
Comparison of the Results between Intramedullary Nailing and Plate Fixation for Distal Tibia Fractures Jung-Han Kim, Heui-Chul Gwak, Chang-Rack Lee, Yang-Hwan Jung Journal of Korean Foot and Ankle Society.2015; 19(3): 86. CrossRef
Minimally Invasive Plate Osteosynthesis for Fractures of Distal Tibia Tae Hun Kim, So Hak Chung Kosin Medical Journal.2014; 29(1): 23. CrossRef
PURPOSE To compare the result of treatment between minimally invasive plate osteosynthesis (MIPO) using periarticular plate and intramedullary nailing in treatment of distal tibia fractures. MATERIALS AND METHODS 28 cases of distal tibia fractures form Jan. 2006 to Mar. 2008 were divided into two group. Minimum follow-up was for 12 month. Group 1 consisted of 14 patients who were treated by MIPO technique and group 2 consisted of 14 patients who were treated by interlocking intramedullary nailing. The results were compared by assessing radiologic and clinical result. RESULTS The mean bony union time was 14 weeks (8~17) in group 1 and 15 weeks (11~20) in group 2. Operation time was 58 minutes (55~65) in group 1 and 82.7 minutes (70~100) in group 2. The average angulation in AP view was 1.5 degrees (0~2) in group 1 and 2 degrees (0~5) in group 2, in lateral view was 1.8 degrees (0~4) in group 1 and 2.3 degrees (0~12) in group 2. The average range of motion for dorsi flextion was 17.5 degrees (15~20) in group 1 and 18 degrees (16~20) in group 2, for plantar flextion was 45 degrees (42~50) in group 1 and 44 degrees (42~50) in group 2, which means that there were no severe limitation of motion in all patients, resulting in satisfactory ambulation. There was no post operative complications such as skin irritation problem caused by internal device and no implant failure and superficial wound infection. CONCLUSION There were no difference in bony union time, clinical result and anatomical reduction between Group 1 and Group 2 in distal tibia fractures, but operation time was shorter in MIPO than nailing.
PURPOSE To assess the result of staged minimally invasive plate osteosynthesis (MIPO) for distal tibial fracture with an open wound or injured soft tissue. MATERIALS AND METHODS In 20 patients (mean age, 47.8 year-old) with distal tibial fractures, there were 4 type A fractures and 16 type C fractures based on the AO classification system. Eight of the 20 patients had open fractures. MIPO was performed on average 23.9 days after bridging external fixation. At the final follow-up, we assessed the radiological results of bone union and alignment. Functional results were also evaluated by measuring the degrees of ankle motion and the American Orthopedic Foot & Ankle Society (AOFAS) scores. RESULTS Seventeen of 20 cases (85%) achieved primary union at an average of 21.3 weeks. There were 3 cases of nonunion requiring a bone graft. The mean AOFAS score was 88.5 (range, 67~92) and the average range of ankle motion was 49.2degrees (plantarflexion: 37.4degrees, dorsiflexion: 11.8degrees). Complication included 2 cases of minor mal-alignment, 1 case of claw toe and 1 case of peroneal neuropathy. Patients over the age of 60 had lower functional results. Additional factors did not affect the final results. CONCLUSION Staged MIPO may achieve satisfactory results in distal tibial fractures with soft tissue compromise, decreasing deep infections and soft tissue complications.
Citations
Citations to this article as recorded by
Anterolateral Minimally Invasive Plate Osteosynthesis of Distal Tibial Fractures Using an Anterolateral Locking Plate Dongwhan Suh, Hwan Hee Lee, Young Hoon Han, Jae Jung Jeong Journal of Korean Foot and Ankle Society.2020; 24(1): 19. CrossRef
Minimally Invasive Osteosynthesis with Locking Compression Plate for Distal Tibia Fractures Sung-Kyu Kim, Keun-Bae Lee, Keun-Young Lim, Eun-Sun Moon Journal of the Korean Fracture Society.2011; 24(1): 33. CrossRef
PURPOSE To evaluate the efficacy of minimally invasive percutaneous plate osteosynthesis (MIPPO) using a lateral plate (Zimmer, Periarticular Lateral Distal Tibial Plates, USA) in distal tibial fracture within 3 cm to plafond, associated with medial soft tissue damage. MATERIALS AND METHODS From January 2005 to December 2007, 15 patients with distal tibial fracture treated by MIPPO technique using a lateral plate were analyzed. The duration of follow-up was more than 1 year. We evaluated union time by simple X-ray, clinical results by IOWA ankle rating system, and complication. RESULTS The bone union was achieved in all cases at average 16.7 weeks. Evaluation of the ankle function test showed an average of 90.3 points, resulting in satisfactory. At the last follow-up, there was no non-union, angular deformity more than 5 degrees or infection. CONCLUSION We concluded that MIPPO technique using a lateral plate is a efficient method for high functional recovery with good bone healing and low complication in distal tibial fracture within 3 cm to plafond, associated with medial soft tissue damage.
Citations
Citations to this article as recorded by
Anatomically Percutaneous Wiring Reduction in Minimally Invasive Plate Osteosynthesis for Distal Tibial Fractures Young-Mo Kim, Chan Kang, Deuk-Soo Hwang, Yong-Bum Joo, Woo-Yong Lee, Jung-Mo Hwang Journal of the Korean Fracture Society.2011; 24(3): 230. CrossRef
Minimally Invasive Osteosynthesis with Locking Compression Plate for Distal Tibia Fractures Sung-Kyu Kim, Keun-Bae Lee, Keun-Young Lim, Eun-Sun Moon Journal of the Korean Fracture Society.2011; 24(1): 33. CrossRef
PURPOSE To compare the effectiveness between minimally invasive plate osteosynthesis (MIPO) and interlocking IM nailing in the treatment of distal tibia fracture without involvement of ankle joint retrospectively. MATERIALS AND METHODS 38 patients with distal tibia fracture from Jan. 2004 to Oct. 2005 were divided into two groups. Minimum follow-up was for 12 months. Group MIPO consisted of 18 patients were treated with MIPO and group Nail consisted of 20 patients were treated with interlocking intramedullary nail. The results were compared between two groups by assessing bony union time and operation time. Clinical evaluation was evaluated by Olerud score. RESULTS The mean bony union time was 14.4 weeks (12~17 weeks) in group MIPO and 16.7 weeks (13~19 weeks) in group Nail (p=0.011). The mean operation time was 1.05 hours (0.6~1.6 hours) in group MIPO and 0.74 hours (0.4~1.1 hours) in group Nail (p=0.044). The Olerud score was 83.8 (75~100) in group MIPO and was 89.6 (70~100) in group Nail (p=0.075). In Complication, group MIPO showed one metal failure and two skin irritations, group Nail showed three superficial wound infections. CONCLUSION MIPO was the shorter bony union time and the longer operation time than the interlocking intramedullary nailing. There were no significant differences between the two groups in clinical results.
Citations
Citations to this article as recorded by
Comparative Analysis of Minimally Invasive Plate Osteosynthesis and Intramedullary Nailing in the Treatment of the Distal Tibia Fractures Ho-Min Lee, Young-Sung Kim, Jong-Pil Kim, Phil-Hyun Chung, Suk Kang, Kaung Suk Jo Journal of the Korean Fracture Society.2018; 31(3): 94. CrossRef
A Rehabilitation for Ankle Fracture in Korean Medicine: A Report of 4 Cases Won-Bae Ha, Jong-Ha Lee, Yoon-Seung Lee, Dong-Chan Jo, Jin-Hyun Lee, Jung-Han Lee Journal of Korean Medicine Rehabilitation.2017; 27(4): 171. CrossRef
Comparison of the Results between Intramedullary Nailing and Plate Fixation for Distal Tibia Fractures Jung-Han Kim, Heui-Chul Gwak, Chang-Rack Lee, Yang-Hwan Jung Journal of Korean Foot and Ankle Society.2015; 19(3): 86. CrossRef
Intramedullary Nailing of Distal Tibial Fractures with Percutaneous Reduction by Pointed Reduction Forceps Jae-Kwang Hwang, Chung-Hwan Kim, Young-Joon Choi, Gi-Won Lee, Hyun-Il Lee, Tae-Kyung Kim Journal of the Korean Fracture Society.2014; 27(2): 144. CrossRef
A Comparison of the Results between Intramedullary Nailing and Minimally Invasive Plate Osteosynthesis in Distal Tibia Fractures Chul-Hyun Park, Chi-Bum Choi, Bum-Jin Shim, Dong-Chul Lee, Oog-Jin Shon Journal of the Korean Orthopaedic Association.2014; 49(4): 285. CrossRef
Analysis of the Result Treated with Locking Compression Plate-Distal Tibia and Zimmer Periarticular Locking Plate in Distal Tibia Fracture Jun-Young Lee, Sang-Ho Ha, Sung-Won Cho, Sung-Hae Park Journal of the Korean Fracture Society.2013; 26(2): 118. CrossRef
PURPOSE To evaluate the outcomes of distal tibial open fractures treated by two-staged delayed minimally invasive percutaneous plate osteosynthesis (MIPPO) technique. MATERIALS AND METHODS 25 cases of distal tibial open fractures were treated with temporary ring fixation and two-staged delayed MIPPO. A mean age was 46 years old, follow-up was 23 months. The type of fracture was evaluated using the AO/OTA classification. The type of open fracture was evaluated using the Gustilo-Anderson classification that revealed 6 cases of type I, 9 cases of type II, 8 cases of type IIIA and 2 cases of type IIIB. We analyzed the radiologic results and postoperative complications. The clinical and functional result were evaluated by using Teeny and Wiss scores. RESULTS The average time of bone union was 18 weeks in 24 cases. There were three delayed union that achieved union twenty weeks after second operation, and 1 case underwent bone graft with additional plate fixation. 6 cases of skin necrosis were treated with skin graft, 2 cases were treated with flap. The clinical and functional assessment showed that 6 cases were excellent, 16 cases were good, 2 cases were fair, and 1 case were poor results. CONCLUSION Two-staged MIPPO technique for distal tibia open fractures seems to be a good procedure to obtain bone union.
Citations
Citations to this article as recorded by
Combined minimally invasive external and internal fixation in the treatment of pilon fractures AhmedSh Rizk, MohamadS Singer, MohamadE Al-Ashhab The Egyptian Orthopaedic Journal.2014; 49(3): 259. CrossRef
Staged Protocol in Treatment of Open Distal Tibia Fracture: Using Lateral MIPO Oog Jin Sohn, Dong Hwa Kang Clinics in Orthopedic Surgery.2011; 3(1): 69. CrossRef
Management of Open Fracture Gu-Hee Jung Journal of the Korean Fracture Society.2010; 23(2): 236. CrossRef
Staged Minimally Invasive Plate Osteosynthesis of Distal Tibial Fractures Sung-Ki Park, Chang-Wug Oh, Jong-Keon Oh, Kyung-Hoon Kim, Woo-Kie Min, Byung-Chul Park, Won-Ju Jeong, Joo-Chul Ihn Journal of the Korean Fracture Society.2010; 23(3): 289. CrossRef
PURPOSE We analyed the mid-term results of distal tibial fractures treated with ilizarov external fixator and functional results according to delayed metaphyseal healing and fracture pattern. MATERIALS AND METHODS We reviewed 23 distal tibial fractures treated with ilizarov external fixator followed for minimum two year (mean 53 months). There were 10 A fractures, 2 B fractures, and 11 C fractures according to the AO classification. Radiographically, we analyzed bony union time according to translation of diaphyseal-metaphyseal fracture line and assessed arthritic score. Functional results was assessed with AOFAS score and analyzed according to delayed healing and fracture pattern. RESULTS Average union time was 21 weeks. Delayed healing of metaphyseal fracture line was associated translational displacement >3 mm (p=0.01). AOFAS scrore was averaged to 68 and there was no stastical significance between delayed metaphyseal healing and functional results (p=0.31). But, low AOFAS score and arthritis score was related to fracture type (p=0.02). In 11 C fractures, radiographic arthritic change were developed in 6 cases (55%). CONCLUSION The main prognosis of distal tibial fractures depends on articular involvement and to shorten the external fixation time, metaphyseal fracture should be reduced within 3mm.
PURPOSE To evaluate the clinical results of minimally invasive percutaneous plate osteosynthesis using a periarticular plate (Zimmer, Warsaw, IN, USA) for distal tibia fractures. MATERIALS AND METHODS 27 patients with distal tibia fractures were treated operatively by minimally invasive percutaneous plate osteosynthesis. The patients were followed for at least 1 year. The duration for bone union, complications after the surgery, the amount of skin irritation at the site of plate insertion was evaluated using the VAS score and the Olerud and Molander ankle score. The average age of the patients was 56 years old (range, 30~81 years) with an average follow up period of 21 months (range, 12~30 months). RESULTS The average time from trauma to surgery was 6 days (range, 2~19 days). 10 cases showed an associated distal fibular fracture. The average time for bone fusion was 14 weeks (range, 8~40 weeks) with 1 case of angular deformity with more than 5 degrees. The amount of skin irritation due to the periarticular plate resulted in a VAS score of 2.2 points. Evaluation of the ankle function test showed an average of 90.2 points, resulting in satisfactory. CONCLUSION The periarticular plate used in minimally invasive percutaneous plate osteosynthesis for distal tibia fractures was concluded to give a firm fixation of the fracture site as bony fusion could be acquired without any callus formation, and few skin irritation due to plate has seem to be an advantage.
Citations
Citations to this article as recorded by
Minimally Invasive Osteosynthesis with Locking Compression Plate for Distal Tibia Fractures Sung-Kyu Kim, Keun-Bae Lee, Keun-Young Lim, Eun-Sun Moon Journal of the Korean Fracture Society.2011; 24(1): 33. CrossRef
Anatomically Percutaneous Wiring Reduction in Minimally Invasive Plate Osteosynthesis for Distal Tibial Fractures Young-Mo Kim, Chan Kang, Deuk-Soo Hwang, Yong-Bum Joo, Woo-Yong Lee, Jung-Mo Hwang Journal of the Korean Fracture Society.2011; 24(3): 230. CrossRef
Minimally Invasive Percutaneous Plate Osteosynthesis Using a Lateral Plate in Distal Tibial Fracture Oog Jin Shon, Dae Sung Kim Journal of the Korean Fracture Society.2010; 23(1): 42. CrossRef
PURPOSE To compare the radiological and clinical results between intramedullary nailing and plate fixation in the treatment of distal tibial fractures. MATERIALS AND METHODS 19 cases of distal tibial metaphyseal fractures within 4 cm of the ankle joint line were enrolled. Ten patients were treated with interlocking intramedullary nail and the others with plate and screws. RESULTS The mean union time was 14 weeks in nailing group and 16 weeks in plate group. The average angulation in AP view was 4.1 degrees in nailing group and 3.1 degrees in plate group. The average angulation in lateral view was 1.7 degrees in nailing group and 2.7 degrees in plate group. The rotational deformity was 2.8 degrees in nailing group and 1.7 degrees in plate group in average. There was no implant failure and soft tissue problem. CONCLUSION There was no difference in clinical and radiological results between intramedullary nailing and plate in the treatment of the distal tibial fractures and, considering the preservation of the soft tissue, the intramedullary nails are a reliable method for managing distal metaphyseal fractures of the tibia.
Citations
Citations to this article as recorded by
Does a Customized 3D Printing Plate Based on Virtual Reduction Facilitate the Restoration of Original Anatomy in Fractures? Seung-Han Shin, Moo-Sub Kim, Do-Kun Yoon, Jae-Jin Lee, Yang-Guk Chung Journal of Personalized Medicine.2022; 12(6): 927. CrossRef
A Comparison of the Results between Intramedullary Nailing and Minimally Invasive Plate Osteosynthesis in Distal Tibia Fractures Chul-Hyun Park, Chi-Bum Choi, Bum-Jin Shim, Dong-Chul Lee, Oog-Jin Shon Journal of the Korean Orthopaedic Association.2014; 49(4): 285. CrossRef
PURPOSE To evaluate the effectivity of interlocking intramedullary nailing for distal tibia fracture and prognostic factor to bone healing. MATERIALS AND METHODS From April 2000 to June 2005, 21 cases who had distal tibia fracture were treated by interlocking intramedullary nail were analyzed. The duration of follow-up was more than 1 year. We evaluated clinical results by IOWA ANKLE rating system and union time by simple X-ray. Furthermore, we estimated prognostic factor to union time. RESULTS The bone union was achieved at average 18.5 weeks. At the last follow-up, there was no non-union and infection. Average IOWA ANKLE rating score was 91.3 point. The union time was delayed in open and segmental fracture at initial fracture. And severe soft tissue injury in open fracture revealed bad result. CONCLUSION We concluded that interlocking intramedullary nail is effective method for treatment of the distal tibial fractures. And, adequate soft tissue management is important to bone healing and clinical outcome.
Citations
Citations to this article as recorded by
Comparison of the Results between Intramedullary Nailing and Plate Fixation for Distal Tibia Fractures Jung-Han Kim, Heui-Chul Gwak, Chang-Rack Lee, Yang-Hwan Jung Journal of Korean Foot and Ankle Society.2015; 19(3): 86. CrossRef
PURPOSE To evaluate the functional results after internal fixation with two low profile plates in fractures of the distal tibia. MATERIALS AND METHODS From March 1998 to October 2002, twelve patients with fractures of the distal tibia were treated with internal fixation using two low profile plates and followed for at least one year. Fractures according to AO/OTA classification were one Type A1, four Type A2, two Type C1, two Type C2 and three Type C3. We analyzed the functional results by the Olerud and Molander ankle scoring system and the postoperative complications. RESULTS The average functional score was 81.2 points and the results were three excellent, six good, one fair and two poor. Bony union was achieved in all cases. There was 1 case of superficial wound infection as a complication. CONCLUSION Internal fixation with two low profile plates in fractures of the distal tibia may minimize the incidence of soft tissue complications and provide good bony union and functional results. Therefore, we consider internal fixation with two low profile plates as a good alternative treatment of the distal tibial fracture.
PURPOSE To evaluate the efficacy of the surgical treatment through the comparison of MIPPO vs open plate fixation in the treatment of the distal tibia fracture retrospectively. MATERIALS AND METHODS 30 patients with distal tibia fracture from Jun. 2001 to Jun. 2004 were divided into two groups depending on the surgical method. Minimum follow up was 12 months. Group A consisted of 15 patients treated with MIPPO, Group B was 15 patients treated with open plate fixation. The clinical outcomes were evaluated retrospectively from operation time, rehabilitation, ROM, interval change of postoperative CRP to assess postoperative inflammatory reaction, postoperative complications and clinical result with the use of McLennan and Ungersma criteria. RESULTS There were no significant differences in clinical result by McLennan and Ungersma criteria in both groups. The postoperative 3 days and 7 days CRP were 4.0mg% (0.9~7.2)/0.5 mg% (0.1~1.5) in group A and 7.97mg% (2.8~14.6)/1.0mg% (0.3~1.6) in group B, shows more minimal tissue injury and early recovery in group A. Operation time in group A was shorter than group B. Normal recovery of ROM was quicker in Group A. In complications, group A showed one superficial infection and one angular deformity and group B showed one superficial infection, one infected nonunion and two ankle stiffness. CONCLUSION There were no significant differences in clinical result and bony union. MIPPO technique is superior to group B in view of the minimal tissue injury, complications, operation time and postoperative rehabilitation.
Citations
Citations to this article as recorded by
Minimally Invasive Percutaneous Plate Osteosynthesis Using a Lateral Plate in Distal Tibial Fracture Oog Jin Shon, Dae Sung Kim Journal of the Korean Fracture Society.2010; 23(1): 42. CrossRef
PURPOSE To evaluate the efficiency of lateral plate fixation using minimally invasive plate osteosynthesis (MIPO) technique as a treatment of distal tibial metaphyseal fracture. MATERIALS AND METHODS Among the patient who were treated from March, 2002 to September, 2004, the cases of twenty patients with distal tibial metaphyseal fracture treated by lateral plate fixation using MIPO technique who were able to be followed up for at least one-year period were reviewed in this study. According to AO/OTA classification, five were type A1, twelve cases were type A2 and other three cases were type A3, and among them two cases were open fracture type I according to the Gustillo-Anderson classification. Radiologic studies and clinical assessment described by Daniel et al and complication following the treatment were evaluated. RESULTS At a mean of 16.4 weeks (range 11 to 23), all fractures united without secondary procedures. According to clinical assessment, all cases had good and excellent result, and there were no complications. CONCLUSION The lateral plate fixation using MIPO technique of distal tibial metaphyseal fracture is an efficient method of treatment with high functional recovery rate which minimize soft tissue damage, decreases the risk of infection and incidence of nonunion at the same time as the classic MIPO technique does, and it is a useful alternative method when there is a anteromedial soft tissue damage.
Citations
Citations to this article as recorded by
Minimally Invasive Plate Osteosynthesis for Fractures of Distal Tibia Tae Hun Kim, So Hak Chung Kosin Medical Journal.2014; 29(1): 23. CrossRef
Staged Protocol in Treatment of Open Distal Tibia Fracture: Using Lateral MIPO Oog Jin Sohn, Dong Hwa Kang Clinics in Orthopedic Surgery.2011; 3(1): 69. CrossRef
Minimally Invasive Percutaneous Plate Osteosynthesis Using a Lateral Plate in Distal Tibial Fracture Oog Jin Shon, Dae Sung Kim Journal of the Korean Fracture Society.2010; 23(1): 42. CrossRef
PURPOSE To demonstrate the effectiveness of the conservative treatment which was introduced to the extraarticular triplane fractures of the distal tibia. MATERIALS AND METHODS We reviewed radiographs and medical records of eight patients with extraarticular triplane fractures of the tibia. Four patients were treated with closed reduction and internal fixation and the others with closed reduction and plaster. RESULTS In all patients, the union of fractures was obtained. Although the physes were closed early, there was no angular deformity or leg length discrepancy. CONCLUSION In case of extraarticular triplane fracture, except for open fracture or failure of closed reduction, conservative treatment yield good result.
PURPOSE To retrospectively reviewed the outcomes and advantages of minimally invasive plate osteosynthesis (MIPO) technique as a new treatment of distal tibial metaphyseal fracture. MATERIALS AND METHODS Nineteen distal tibial metaphyseal fractures were treated by MIPO technique and evaluated radiologically and functionally. A mean age was 46 years old (range 20~69 years) and a mean follow-up was 15 months (range 6~37 months). Sixteen fractures were not extended into ankle joint (AO/OTA type A1;4, A2;8, A3;4) and three fractures were extended into ankle joint (AO/OTA type C1;2, C2;1). Two cases were open fractures (type I;1, type III-A;1) according to the Gustilo-Anderson classification. RESULT At a mean of 18 weeks (range 12 to 24), all fractures united without secondary procedures. A mean score was 94.2 point by Baird ankle scoring system. There were no complications including shortening over 1 cm, mal-alignment over 5 degrees, deep infection, or implant failure. CONCLUSION MIPO technique of distal tibial metaphyseal fracture is a worthwhile method with good unions and functional recovery.
Citations
Citations to this article as recorded by
Comparative Analysis of Minimally Invasive Plate Osteosynthesis and Intramedullary Nailing in the Treatment of the Distal Tibia Fractures Ho-Min Lee, Young-Sung Kim, Jong-Pil Kim, Phil-Hyun Chung, Suk Kang, Kaung Suk Jo Journal of the Korean Fracture Society.2018; 31(3): 94. CrossRef
A Comparison of the Results between Intramedullary Nailing and Minimally Invasive Plate Osteosynthesis in Distal Tibia Fractures Chul-Hyun Park, Chi-Bum Choi, Bum-Jin Shim, Dong-Chul Lee, Oog-Jin Shon Journal of the Korean Orthopaedic Association.2014; 49(4): 285. CrossRef
Analysis of the Result Treated with Locking Compression Plate-Distal Tibia and Zimmer Periarticular Locking Plate in Distal Tibia Fracture Jun-Young Lee, Sang-Ho Ha, Sung-Won Cho, Sung-Hae Park Journal of the Korean Fracture Society.2013; 26(2): 118. CrossRef
Comparative Analysis of Minimally Invasive Plate Osteosynthesis Using Periarticular Plate and Intramedullary Nailing in Distal Tibial Metaphyseal Fractures Gwang Chul Lee, Jun Young Lee, Sang Ho Ha, Hong Moon Sohn, Yi Kyu Park Journal of the Korean Fracture Society.2012; 25(1): 20. CrossRef
Clinical Outcomes of Locking Compression Plate Fixation through Minimally Invasive Percutaneous Plate Osteosynthesis in the Treatment of Distal Tibia Fracture Jae-Sung Yoo, Hyun-Woo Park Journal of the Korean Fracture Society.2012; 25(2): 117. CrossRef
Minimally Invasive Osteosynthesis with Locking Compression Plate for Distal Tibia Fractures Sung-Kyu Kim, Keun-Bae Lee, Keun-Young Lim, Eun-Sun Moon Journal of the Korean Fracture Society.2011; 24(1): 33. CrossRef
Management of Fractures of Distal Tibia by Minimally Invasive Plate Osteosynthesis through an Anterior Approach Gu-Hee Jung, Jae-Do Kim, Jae-Ho Jang, Sung-Keun Heo, Dong-won Lee Journal of the Korean Orthopaedic Association.2010; 45(6): 473. CrossRef
Comparative Study Using of Treatment with Minimally Invasive Plate Osteosynthesis Using Periarticular Plate and Interlocking Intramedullary Nailing in Distal Tibia Fractures Chang Hwa Hong, Jong Seok Park, Sang Seon Lee, Soo Ik Awe, Woo Jong Kim, Ki Jin Jung Journal of the Korean Fracture Society.2010; 23(3): 296. CrossRef
A Comparison between Minimally Invasive Plate Osteosynthesis & Interlocking Intramedullary Nailing in Distal Tibia Fractures Kee-Byung Lee, Si-Young Song, Duek-Joo Kwon, Yong-Beom Lee, Nam-Kyou Rhee, Jun-Ha Choi Journal of the Korean Fracture Society.2008; 21(4): 286. CrossRef
Minimally Invasive Percutaneous Plate Osteosynthesis Using Periarticular Plate for Distal Tibial Fractures Young Mo Kim, Jae Hoon Yang, Dong Kyu Kim Journal of the Korean Fracture Society.2007; 20(4): 315. CrossRef
Treatment of High-energy Distal Tibia Intraarticular Fractures with Two-staged Delayed Minimal Invasive Plate Osteosynthesis Hong-Moon Sohn, Jun-Young Lee, Sang-Ho Ha, Jae-Won You, Sang-Hong Lee, Kwang-Chul Lee Journal of the Korean Fracture Society.2007; 20(1): 19. CrossRef
PURPOSE evaluate the effectiveness of minimally invasive plate osteosynthesis (MIPO) in unstable fractures of the distal tibia. MATERIALS AND METHODS From March 2001 to December 2003, 21 cases with unstable fractures of the distal tibia were treated with MIPO technique and followed for at least one year. Eighteen cases were extra-articular and three cases were intra-articular fractures. According to AO classification, six cases were 42-A, four 42-B, one 42-C, seven 43-A, and three 43-C. There was only one case of Gustilo-Anderson type II open fracture. We reviewed the results of fracture healing, axial and rotational deformity, ankle motion, and complications RESULTS: All fractures were healed in an average of 16.1 weeks (range, 11 to 24 weeks). There was only one case of 7-degree posterior angular deformity, but no cases of rotational malalignment. Recovery of ankle motion was satisfactory in all patients within 5-degree loss of motion. Subcutaneous abscess was developed in one case after fracture healing and cured by a drainage with implant removal. CONCLUSION Although MIPO technique is technically more demanding than the traditional open technique, MIPO technique is an effective method for unstable fractures of the distal tibia because it minimizes incidence of soft-tissue compromise and infection and provides good fracture healing.
Citations
Citations to this article as recorded by
Clinical Outcomes of Locking Compression Plate Fixation through Minimally Invasive Percutaneous Plate Osteosynthesis in the Treatment of Distal Tibia Fracture Jae-Sung Yoo, Hyun-Woo Park Journal of the Korean Fracture Society.2012; 25(2): 117. CrossRef
Staged Protocol in Treatment of Open Distal Tibia Fracture: Using Lateral MIPO Oog Jin Sohn, Dong Hwa Kang Clinics in Orthopedic Surgery.2011; 3(1): 69. CrossRef
Staged Minimally Invasive Plate Osteosynthesis of Distal Tibial Fractures Sung-Ki Park, Chang-Wug Oh, Jong-Keon Oh, Kyung-Hoon Kim, Woo-Kie Min, Byung-Chul Park, Won-Ju Jeong, Joo-Chul Ihn Journal of the Korean Fracture Society.2010; 23(3): 289. CrossRef
Management of Fractures of Distal Tibia by Minimally Invasive Plate Osteosynthesis through an Anterior Approach Gu-Hee Jung, Jae-Do Kim, Jae-Ho Jang, Sung-Keun Heo, Dong-won Lee Journal of the Korean Orthopaedic Association.2010; 45(6): 473. CrossRef
Comparative Study Using of Treatment with Minimally Invasive Plate Osteosynthesis Using Periarticular Plate and Interlocking Intramedullary Nailing in Distal Tibia Fractures Chang Hwa Hong, Jong Seok Park, Sang Seon Lee, Soo Ik Awe, Woo Jong Kim, Ki Jin Jung Journal of the Korean Fracture Society.2010; 23(3): 296. CrossRef
A Comparison between Minimally Invasive Plate Osteosynthesis & Interlocking Intramedullary Nailing in Distal Tibia Fractures Kee-Byung Lee, Si-Young Song, Duek-Joo Kwon, Yong-Beom Lee, Nam-Kyou Rhee, Jun-Ha Choi Journal of the Korean Fracture Society.2008; 21(4): 286. CrossRef
Basic Principle of the Locking Compression Plate Keun Bae Lee Journal of the Korean Fracture Society.2008; 21(3): 261. CrossRef
Treatment of High-energy Distal Tibia Intraarticular Fractures with Two-staged Delayed Minimal Invasive Plate Osteosynthesis Hong-Moon Sohn, Jun-Young Lee, Sang-Ho Ha, Jae-Won You, Sang-Hong Lee, Kwang-Chul Lee Journal of the Korean Fracture Society.2007; 20(1): 19. CrossRef
Minimally Invasive Plate Osteosynthesis, MIPO Young-Soo Byun Journal of the Korean Fracture Society.2007; 20(1): 99. CrossRef
Minimally Invasive Percutaneous Plate Osteosynthesis Using Periarticular Plate for Distal Tibial Fractures Young Mo Kim, Jae Hoon Yang, Dong Kyu Kim Journal of the Korean Fracture Society.2007; 20(4): 315. CrossRef
PURPOSE The purpose of this study is to evaluate the effectiveness of anterolateral approach of the ankle for the distal tibial fracture in aspect of preventing complication and acquiring union. MATERIALS AND METHODS Authors reviewed 21 patients of distal metaphyseal fracture of the tibia treated by anterolateral approach and lateral plating method from February, 2000 to May, 2002. Mean follow-up period was 17 months (12~29 months). There were twelve type A, two type B, and four type C patients according to AO/OTA classification. We have analyzed the bone union rate and Ovadia`s functional scale. We also reviewed the complication rate, such as soft tissue problem and postoperative infection. RESULTS In all cases union was achieved and mean time to union were 16 weeks. The functional result by Ovadia's scale were 17 excellent cases and 4 good cases in objective evaluation, and 19 excellent cases and 2 good cases in subjective evaluation. Wound infection occurred in one case, but the infection was controlled after plate removal and the union was acquired through cast immobilization. There was no other complication, such as soft tissue necrosis. CONCLUSION The anterolateral approach is a safe and worthwhile method for distal tibia fracture while avoiding some of the complication associated with standard anteromedial approach and plating method.