Joon Gue Moon 1 Article
Loss of Fixation after Internal Fixation of Intertrochanteric Femoral Fracture with Compression Hip Screw
Jong Oh Kim, Sang Yeol Chang, Joon Gue Moon, Hoon Jeong, Woo Chul Jeong
J Korean Soc Fract 2003;16(3):334-339.   Published online July 31, 2003
DOI: https://doi.org/10.12671/jksf.2003.16.3.334
AbstractAbstract PDF
PURPOSE
To evaluate the factors which might affect the loss of fixation after surgical treatment of intertrochanteric fracture with compression hip screw.
MATERIALS AND METHODS
From February 1996 to February 2001, seventy nine cases of intertrochanteric fracture which we operated with compression hip screw was reviewed with minimal follow up for 6 months. There were twelve cases of loss of fixation. The cases were analyzed according to each factors which we thought to affect the loss of fixation. The factors are fracture type by modified Evans classification, Singh index, placement of screw in femoral head, quality of reduction. Then we analyzed these factors with chi square test.
RESULTS
Difference between age group and sex were not thought to be statistically meaningful factors (p>0.05). There were difference of prevalence between two group divided by fracture stability (p<0.05). In cases of superior placement in femoral head, there were more loss of fixation. Displacement of cortex of proximal femur on radiologic AP view other than lateral view showed meaningful difference (p<0.05).
CONCLUSION
Age, sex, Singh index did not affect the loss of fixation. But, next factors as follows affected the loss of fixation; Superior placement of hip screw, unstable fracture pattern, displacement of fracture site more than 5 mm after surgical reduction on radiologic AP view.