Skip Navigation
Skip to contents

J Musculoskelet Trauma : Journal of Musculoskeletal Trauma

OPEN ACCESS

Author index

Page Path
HOME > Browse articles > Author index
Search
Jong Keon Oh 38 Articles
Tension Band Wiring Technique for Distal Radius Fracture with a Volar Articular Marginal Fragment: Technical Note
Neunghan Jeon, Jong Keon Oh, Jae Woo Cho, Youngwoo Kim
J Korean Fract Soc 2020;33(1):38-42.   Published online January 31, 2020
DOI: https://doi.org/10.12671/jkfs.2020.33.1.38
AbstractAbstract PDF
Most distal radius fractures are currently being treated with anterior plating using anatomical precontoured locking compression plates via the anterior approach. However, it is difficult to fix the volar articular marginal fragment because these anatomical plates should be placed proximally to the watershed line. There were just a few methods of fixation for this fragment on medical literature. Herein, we introduced a tension band wiring technique for fixation of a volar articular marginal fragment in the distal radius.
  • 216 View
  • 1 Download
Close layer
Treatment Options for the Nonunions with Critical Sized Bone Loss
Jin Kak Kim, Soo Hyun Kim, Jae Woo Cho, Jong Keon Oh
J Korean Fract Soc 2017;30(2):89-101.   Published online April 30, 2017
DOI: https://doi.org/10.12671/jkfs.2017.30.2.89
AbstractAbstract PDF
The management of nonunion with severe bone loss is a challenging task to both surgeons and patients. It often requires prolonged and potentially painful treatments. Moreover, it also represents serious socioeconomic issues for patients. Inadequate fracture stability, disrupted biology, such as blood supply and soft tissue, as well as severe bone loss or presence of infection are possible reasons for nonunion. Several different treatment modalities are available, including nail dynamization, plate osteosynthesis, exchange nailing, and adjuvant alternatives, such as electrical or ultrasound stimulation. Autogenous bone graft remains the standard method to reconstruct small defects. Distraction osteogenesis and induced membrane techniques are contemporary strategies of choice for the reconstruction of larger bony defects. Herein, we attempt to describe the key techniques that may be employed in treating nonunion with severe bone loss.

Citations

Citations to this article as recorded by  
  • Individualized herbal prescriptions for delayed union: A case series
    Jiyoon Won, Youngjin Choi, Lyang Sook Yoon, Jun-Hwan Lee, Keunsun Choi, Hyangsook Lee
    EXPLORE.2023; 19(2): 260.     CrossRef
  • 172 View
  • 0 Download
  • 1 Crossref
Close layer
Assessment of Coronal Plane Malalignment Following Reduction of Trochanteric Fractures-Simple Intraoperative Guideline Using Greater Trochanter Orthogonal Line
Young Cheol Yoon, Jong Keon Oh, Won Yong Shon, Han Ju Kim, Jae Woo Cho
J Korean Fract Soc 2016;29(1):1-11.   Published online January 31, 2016
DOI: https://doi.org/10.12671/jkfs.2016.29.1.1
AbstractAbstract PDF
PURPOSE
There is no consensus on a clear intraoperative guideline for judging the coronal plane alignment following reduction of trochanteric fractures. Complex angular measurements using fluoroscope monitors are tedious. Therefore the relation of the horizontal line from the tip of the greater trochanter (GT orthogonal) and femur head center (HC orthogonal) was studied to define this line as a criterion for predicting varus-valgus malalignment.
MATERIALS AND METHODS
We studied this relation in 200 standing orthoradiograms which included 100 males and 100 females. The images were digitally analyzed using the picture archiving and communication system. GT orthogonal line and HC orthogonal line were evaluated. The distance of these lines was measured as trochanter center distance (TCD) and its correlation with angular parameters like neck shaft angle, medial proximal femoral angle with reference to anatomical axis (aMPFA) and lateral proximal femoral angle with reference to mechanical axis (mLPFA) were analyzed.
RESULTS
In all patients, the GT orthogonal line passed either at or above the center of the head. Overall mean of TCD was 7.22 mm, ranging from 0 to 17.57 mm. TCD was found to show strong correlation with angular parameters like aMPFA, mLPFA and neck shaft angle. TCD was less than one fourth of the corresponding head diameter in around 90%. Therefore following reduction of trochanteric fractures, the GT orthogonal line should pass through the superior juxta central quadrant of the femoral head.
CONCLUSION
This line can be represented by a guide wire with fluoroscopy during surgery. The GT orthogonal line can be used intraoperatively as a simplified tool for prediction of varus/valgus malalignment following the reduction of trochanteric fractures.
  • 133 View
  • 0 Download
Close layer
Management of Long Bone Fractures with Severe Bone Defect
Jae Woo Cho, Jinil Kim, Han Ju Kim, Jong Keon Oh
J Korean Fract Soc 2015;28(3):205-214.   Published online July 31, 2015
DOI: https://doi.org/10.12671/jkfs.2015.28.3.205
AbstractAbstract PDF
No abstract available.

Citations

Citations to this article as recorded by  
  • Treatment Strategy of Infected Nonunion
    Hyoung-Keun Oh
    Journal of the Korean Fracture Society.2017; 30(1): 52.     CrossRef
  • 214 View
  • 4 Download
  • 1 Crossref
Close layer
Diagnosis and Management of Posttraumatic Chronic Osteomyelitis
Jong Hoon Kim, Yong Cheol Yoon, Young Woo Kim, Sung Ho Jung, Jong Keon Oh
J Korean Fract Soc 2014;27(1):88-104.   Published online January 31, 2014
DOI: https://doi.org/10.12671/jkfs.2014.27.1.88
AbstractAbstract PDF
No abstract available.

Citations

Citations to this article as recorded by  
  • Treatment Strategy of Infected Nonunion
    Hyoung-Keun Oh
    Journal of the Korean Fracture Society.2017; 30(1): 52.     CrossRef
  • 164 View
  • 2 Download
  • 1 Crossref
Close layer
The Result of Conservative Treatment of Proximal Humerus Fracture in Elderly Patients
Seung Gil Baek, Chang Wug Oh, Young Soo Byun, Jong Keon Oh, Joon Woo Kim, Jong Pil Yoon, Hyun Joo Lee, Hyung Sub Kim
J Korean Fract Soc 2013;26(4):292-298.   Published online October 31, 2013
DOI: https://doi.org/10.12671/jkfs.2013.26.4.292
AbstractAbstract PDF
PURPOSE
With the increase in the old age population, proximal humerus fractures have been increasing recently. However, complications after operative treatment, such as fixation failure, are common because of osteoporosis. We treated proximal humerus fractures in patients with osteoporosis conservatively, and evaluated the radiographic and functional results by analyzing the factors affecting the results.
MATERIALS AND METHODS
Nineteen out of 30 cases for whom the clinical follow-up was over 1 year were included in this retrospective study. There were 17 females and 2 males, and the mean age was 73.2 years. The causes were slip from a short height (18 cases) and a minor car accident (1 case). We evaluated the union period, nonunion, malunion and the Constant score and analyzed several factors affecting the functional result, such as age, fracture pattern, and malunion.
RESULTS
Seventeen cases (89.5%) obtained union within 12.8 weeks on average. Neck-shaft angle was 125.3degrees on average, with seven cases of malunion. The Constant score was 84.1 on average, and there were excellent scores in 11 cases, good scores in 4 cases, and fair scores in 2 cases. Fracture pattern, neck-shaft angle, or malunion did not affect the functional outcome, and elderly patients showed poorer shoulder function.
CONCLUSION
Proximal humeral fractures with osteoporosis may achieve a high rate of bony union when treated with conservative methods. Despite the common occurrence of malunion, a satisfactory functional outcome may be expected.
  • 134 View
  • 2 Download
Close layer
Treatment of Distal Humeral Fractures
Yong Cheol Yoon, Jong Keon Oh
J Korean Fract Soc 2012;25(3):223-232.   Published online July 31, 2012
DOI: https://doi.org/10.12671/jkfs.2012.25.3.223
AbstractAbstract PDF
No abstract available.

Citations

Citations to this article as recorded by  
  • Paratricipital Approach for AO/OTA Type C2 Intra-Articular Fracture of Distal Humerus
    Chul-Hyung Lee, Doo-Hun Sun, Deukhee Jung, Chung-Han An
    Journal of the Korean Fracture Society.2019; 32(3): 128.     CrossRef
  • How Difficult Is It to Surgically Treat AO-C Type Distal Humerus Fractures for Inexperienced Orthopedic Surgeons?
    Seong Ho Yoo, Suk Woong Kang, Moo Ho Song, Young Jun Kim, Hyuck Bae
    Journal of the Korean Fracture Society.2018; 31(2): 45.     CrossRef
  • 161 View
  • 0 Download
  • 2 Crossref
Close layer
Staged Minimally Invasive Plate Osteosynthesis of Distal Tibial Fractures
Sung Ki Park, Chang Wug Oh, Jong Keon Oh, Kyung Hoon Kim, Woo Kie Min, Byung Chul Park, Won Ju Jeong, Joo Chul Ihn
J Korean Fract Soc 2010;23(3):289-295.   Published online July 31, 2010
DOI: https://doi.org/10.12671/jkfs.2010.23.3.289
AbstractAbstract PDF
PURPOSE
To assess the result of staged minimally invasive plate osteosynthesis (MIPO) for distal tibial fracture with an open wound or injured soft tissue.
MATERIALS AND METHODS
In 20 patients (mean age, 47.8 year-old) with distal tibial fractures, there were 4 type A fractures and 16 type C fractures based on the AO classification system. Eight of the 20 patients had open fractures. MIPO was performed on average 23.9 days after bridging external fixation. At the final follow-up, we assessed the radiological results of bone union and alignment. Functional results were also evaluated by measuring the degrees of ankle motion and the American Orthopedic Foot & Ankle Society (AOFAS) scores.
RESULTS
Seventeen of 20 cases (85%) achieved primary union at an average of 21.3 weeks. There were 3 cases of nonunion requiring a bone graft. The mean AOFAS score was 88.5 (range, 67~92) and the average range of ankle motion was 49.2degrees (plantarflexion: 37.4degrees, dorsiflexion: 11.8degrees). Complication included 2 cases of minor mal-alignment, 1 case of claw toe and 1 case of peroneal neuropathy. Patients over the age of 60 had lower functional results. Additional factors did not affect the final results.
CONCLUSION
Staged MIPO may achieve satisfactory results in distal tibial fractures with soft tissue compromise, decreasing deep infections and soft tissue complications.

Citations

Citations to this article as recorded by  
  • Anterolateral Minimally Invasive Plate Osteosynthesis of Distal Tibial Fractures Using an Anterolateral Locking Plate
    Dongwhan Suh, Hwan Hee Lee, Young Hoon Han, Jae Jung Jeong
    Journal of Korean Foot and Ankle Society.2020; 24(1): 19.     CrossRef
  • Minimally Invasive Osteosynthesis with Locking Compression Plate for Distal Tibia Fractures
    Sung-Kyu Kim, Keun-Bae Lee, Keun-Young Lim, Eun-Sun Moon
    Journal of the Korean Fracture Society.2011; 24(1): 33.     CrossRef
  • 127 View
  • 0 Download
  • 2 Crossref
Close layer
Effect of Fracture Gap on Biomechanical Stability of Compression Bone-Plate Fixation System after Bone Fracture Augmentation
Duk Young Jung, Sung Jae Lee, Seon Chil Kim, Jong Keon Oh
J Korean Fract Soc 2010;23(2):220-226.   Published online April 30, 2010
DOI: https://doi.org/10.12671/jkfs.2010.23.2.220
AbstractAbstract PDF
PURPOSE
The goal of this study using the biomechanical test was to evaluate the mechanical stability of the bone-plate fixation system according to changes of the fracture gap sizes and widths.
MATERIALS AND METHODS
For mechanical test, four types with different fracture models simulating the clinical situations were constructed depending on the gap size (FGS, mm) and the gap width (FGW, %) at the fracture site: 0 mm/0%, 1 mm/100%, 4 mm/100%, 4 mm/50%. For analyzing the effects of fracture gap on the biomechanical stability of the bone-plate fixation system, 4-point bending test was performed under all same conditions.
RESULTS
It was found that the fracture gap sizes of 1 and 4 mm decreased mechanical stiffness by about 50~60% or more. Furthermore, even without fracture gap size, 50% or more fracture gap width considerably decreased mechanical stiffness and suggested the possibility of plate damage through strain results.
CONCLUSION
Our findings suggested that at least 50% contact of the fracture faces in a fracture surgery would be maintained to increase the mechanical stability of the bone-plate fixation system.
  • 113 View
  • 1 Download
Close layer
A Finite Element Analysis of Biomechanical Stability of Compression Plate Fixation System in according to Existing of Fracture Gap after Bone Fracture Augmentation
Duk Young Jung, Bong Ju Kim, Jong Keon Oh
J Korean Fract Soc 2010;23(1):83-89.   Published online January 31, 2010
DOI: https://doi.org/10.12671/jkfs.2010.23.1.83
AbstractAbstract PDF
PURPOSE
This study using the finite element analysis (FEA) focused on evaluating the biomechanical stability of the LC-DCP in accordance with existing of the fracture gap at the facture site after bone fracture augmentation.
MATERIALS AND METHODS
For FEM analysis, total eleven types with different fracture models considering clinical fracture cases were constructed according to the fracture gap sizes (0, 1, 4 mm)/widths (0, 25, 50, 75, 100%). Limited contact dynamic compression plate (LC-DCP) fixation system was used in this FEM analysis, and three types of load were applied to the bone-plate fixation system: compressive, torsional, bending load.
RESULTS
The results in FEM analysis showed that the 1, 4 mm fracture gap sizes and 75% or more fracture gap widths increased considerably the peak von Mises stress (PVMS) both the plate and the screw under all loading conditions. PVMS were concentrated on the center of the LC-DCP bone-plate, and around the necks of screws.
CONCLUSION
Based on the our findings, we recommend at least 50% contact of the fracture faces in a fracture surgery using the compression bone-plate system. Moreover, if x-ray observation after surgery finds 100% fracture gap or 50% or more fracture gap width, supplementary measures to improve biomechanical stability must be taken, such as restriction of walking of the patient or plastering.

Citations

Citations to this article as recorded by  
  • Application of Patient-Specific 3D-Printed Orthopedic Splint for Bone Fracture in Small Breed Dogs
    Kwangsik Jang, Eun Joo Jang, Yo Han Min, Kyung Mi Shim, Chunsik Bae, Seong Soo Kang, Se Eun Kim
    Journal of Veterinary Clinics.2023; 40(4): 268.     CrossRef
  • 124 View
  • 0 Download
  • 1 Crossref
Close layer
Osteoporotic Pertrochanteric Fracture: IM Nailing
Jong Keon Oh, Jin Ho Hwang
J Korean Fract Soc 2009;22(1):56-65.   Published online January 31, 2009
DOI: https://doi.org/10.12671/jkfs.2009.22.1.56
AbstractAbstract PDF
No abstract available.

Citations

Citations to this article as recorded by  
  • The Determination of Optimal Entry Point for Proximal Femoral Nail Antirotation-II by Fluoroscopic Simulation: A Cadaveric Study
    Jin-Hoon Jeong, Gu-Hee Jung
    Journal of the Korean Fracture Society.2017; 30(4): 173.     CrossRef
  • Analysis of Low-Energy Trochanter Fracture Using the Multiplanar Computed Tomography Image: Application for Intramedullary Nail Fixation
    Gu-Hee Jung, Sung-Keun Heo, Hyun-Je Seo
    Journal of the Korean Fracture Society.2015; 28(3): 155.     CrossRef
  • Results of Asian Type Gamma 3 Nail in Treatment of Trochanteric Fractures
    Bing Zhe Huang, Yong Wook Park, Jin Su Park, Kyu Cheol Noh, Soung Yon Kim, Kook Jin Chung, Hong Kyun Kim, Hyong Nyun Kim, Yong Hyun Yoon, Ji Hyo Hwang
    Journal of the Korean Fracture Society.2014; 27(3): 213.     CrossRef
  • Comparative Study of Intertrochanteric Fracture Treated with the Proximal Femoral Nail Anti-Rotation and the Third Generation of Gamma Nail
    Jae-Cheon Sim, Tae-Ho Kim, Ki-Do Hong, Sung-Sik Ha, Jong-Seong Lee
    Journal of the Korean Fracture Society.2013; 26(1): 37.     CrossRef
  • Comparison of the Dyna Locking Trochanteric Nail, Proximal Femoral Nail Antirotation and Gamma 3 Nail in Treatment of Intertrochanteric Fracture of the Femur
    Sung Soo Kim, Kyu Yeol Lee, Chul Hong Kim, Myung Jin Lee, Lih Wang, Hyeon Jun Kim, Sun Hyo Kim
    Hip & Pelvis.2013; 25(3): 211.     CrossRef
  • Lateral Positioning for Proximal Femoral Nailing of the Intertrochanteric Fracture - Surgical Technique -
    Kwan-Hee Lee, Hoon Jeong, Jong-Kyoung Ha, Yong-Ju Kim, Won-Hee Jang
    Journal of the Korean Fracture Society.2011; 24(1): 79.     CrossRef
  • Treatment of the Intertrochanteric Femoral Fracture with Proximal Femoral Nail: Nailing Using the Provisional K-wire Fixation
    Gu-Hee Jung
    Journal of the Korean Fracture Society.2011; 24(3): 223.     CrossRef
  • Comparison of the Compression Hip Screw (CHS) and the Proximal Femoral Nail Antirotation (PFNA) for Intertrochanteric Femoral Fracture
    Jong Min Lim, Jeung Il Kim, Jong Seok Oh, Kuen Tak Suh, Jae Min Ahn, Dong Joon Kang
    Journal of the Korean Fracture Society.2010; 23(4): 360.     CrossRef
  • Helical Blade versus Lag Screw for Treatment of Intertrochanteric Fracture
    Kwang-Jun Oh, Sung-Tae Lee, Suk-Ha Lee, Jin-Ho Hwang, Min-Suk Kang
    Journal of the Korean Fracture Society.2010; 23(1): 6.     CrossRef
  • 121 View
  • 1 Download
  • 9 Crossref
Close layer
Staged Minimally Invasive Plate Osteosynthesis of Proximal Tibial Fracture
Joon Woo Kim, Chang Wug Oh, Jong Keon Oh, Hee Soo Kyung, Woo Kie Min, Byung Chul Park, Kyung Hoon Kim, Hee Joon Kim
J Korean Fract Soc 2009;22(1):6-12.   Published online January 31, 2009
DOI: https://doi.org/10.12671/jkfs.2009.22.1.6
AbstractAbstract PDF
PURPOSE
To assess the results of staged MIPO (Minimally Invasive Plate Osteosynthesis) for proximal tibial fractures with compromised soft tissue.
MATERIALS AND METHODS
Eighteen proximal tibial fractures (AO 41:9 cases, AO 42:9 cases) included this study. Ten were open fractures. After temporary external fixation until soft tissue healed (mean 27.3 days), MIPO was performed secondarily without bone graft. We assessed the bony union and knee function, and affecting factors of the results were investigated.
RESULTS
All fractures united at 20 weeks (range, 11~32) except 1 case. Mean range of knee flexion was 134.4degrees and mean IOWA knee score was 89.1. There were 2 superficial and 2 delayed deep infections from open fractures (grade II:1 case, grade III:3 cases), although they healed after implant removal. Open fractures seem to influence the infection rate. Otherwise, there was no related factor affecting the results.
CONCLUSION
MIPO after temporary external fixation can provide favorable results in proximal tibial fractures with soft tissue injuries, but attention of delayed infection should be paid in open fractures.

Citations

Citations to this article as recorded by  
  • MINIMALLY INVASIVE OSTEOSYNTHESIS WITH PLATE OR NAIL FOR META-DIAPHYSEAL TIBIAL FRACTURES - WHAT IS BETTER?
    B. Makelov
    Trakia Journal of Sciences.2023; 21(4): 357.     CrossRef
  • Effect of Korean Medicine Treatments in Patients with Proximal Tibia Fracture: A Retrospective Observational Study
    Jung Min Lee, Eun-Jung Lee
    Journal of Korean Medicine Rehabilitation.2020; 30(3): 141.     CrossRef
  • Comparison of Time to Operation and Efficacies of Ultrasound-Guided Nerve Block and General Anesthesia in Emergency External Fixation of Lower Leg Fractures (AO 42, 43, 44)
    Chan Kang, Sang-Bum Kim, Youn-Moo Heo, You-Gun Won, Byung-Hak Oh, June-Bum Jun, Gi-Soo Lee
    The Journal of Foot and Ankle Surgery.2017; 56(5): 1019.     CrossRef
  • Minimally Invasive Plate Osteosynthesis for Proximal Tibial Shaft Fracture
    Young-Soo Byun, Ki-Chul Park, Hyun-Jong Bong, Chang-Hoon Lee
    Journal of the Korean Fracture Society.2011; 24(1): 23.     CrossRef
  • The Use of Fresh Frozen Allogenic Bone Graft in the Impacted Tibial Plateau Fractures
    Yeung Jin Kim, Soo Uk Chae, Jung Hwan Yang, Ji Wan Lee, Dae Han Wi, Duk Hwa Choi
    Journal of the Korean Fracture Society.2010; 23(1): 26.     CrossRef
  • Management of Open Fracture
    Gu-Hee Jung
    Journal of the Korean Fracture Society.2010; 23(2): 236.     CrossRef
  • Staged Minimally Invasive Plate Osteosynthesis of Distal Tibial Fractures
    Sung-Ki Park, Chang-Wug Oh, Jong-Keon Oh, Kyung-Hoon Kim, Woo-Kie Min, Byung-Chul Park, Won-Ju Jeong, Joo-Chul Ihn
    Journal of the Korean Fracture Society.2010; 23(3): 289.     CrossRef
  • Intramedullary Nailing of Proximal Tibial Fractures
    Young-Soo Byun, Dong-Ju Shin
    Journal of the Korean Fracture Society.2009; 22(3): 197.     CrossRef
  • Proximal Tibia Fracture: Plating
    Ki-Chul Park
    Journal of the Korean Fracture Society.2009; 22(3): 206.     CrossRef
  • 181 View
  • 0 Download
  • 9 Crossref
Close layer
Bone Transport Over the Intramedullary Nail for Defects of Long Bone
Jae Young Roh, Chang Wug Oh, Jong Keon Oh, Hee Soo Kyung, Byung Chul Park, Woo Kie Min, Joon Woo Kim, Chang Hyun Cho
J Korean Fract Soc 2008;21(1):37-44.   Published online January 31, 2008
DOI: https://doi.org/10.12671/jkfs.2008.21.1.37
AbstractAbstract PDF
PURPOSE
To evaluate the results of bone transport using external fixator over an intramedullary nail for defects of long bone.
MATERIALS AND METHODS
We treated 14 cases of bone defect after chronic osteomyelitis or trauma of tibia (12 cases) and femur (2 cases) using this method. The mean age of index procedure was 46.9 years, and all of them had follow-up study for a mean of 3 years. After the corticotomy and insertion of intramedullary nail, bone transport was done by external fixators. Then, the segment was moved and bone graft was done at docking site.
RESULTS
The mean transported amount was 5.8 cm, and the external fixator was removed after 141 days. The mean external fixation index was 25.6 days/cm. Primary union of distraction and docking site was achieved in all, but one had failure in union of docking site. According to the Mekhail's functional criteria, there were 5 excellent, 6 good, and 3 fair results. Among 15 complications, there were 2 major complications with residual sequelae, and they were 1 recurred osteomyelitis and 1 flexion contracture of knee.
CONCLUSION
Bone transport using external fixator over an intramedullary nail, can successfully solve defects of long bone. Since this method can remove external fixators earlier than the conventional method, it has fewer complications and makes patients to return to daily life earlier.

Citations

Citations to this article as recorded by  
  • Treatment for Bone Defect of Open Tibial Fractures by Using Intramedullary Nail Fixation with Autogenous Iliac Bone Graft
    Hyub Sakong, Ki Cheor Bae, Chul Hyun Cho, Kyung Jae Lee, Eun Seok Son, Du Han Kim
    Journal of the Korean Fracture Society.2012; 25(4): 288.     CrossRef
  • 280 View
  • 7 Download
  • 1 Crossref
Close layer
Pitfalls and Complications in the Application of the Locking Plate
Jong Keon Oh
J Korean Fract Soc 2007;20(4):355-360.   Published online October 31, 2007
DOI: https://doi.org/10.12671/jkfs.2007.20.4.355
AbstractAbstract PDF
No abstract available.
  • 80 View
  • 1 Download
Close layer
Comparison of Operative Methods between Retrograde and Antegrade Nailing for Ipsilateral Femoral Shaft and Neck Fracture
Chang Wug Oh, Jong Keon Oh, Woo Kie Min, Shin Yoon Kim, Seung Hoon Baek, Byung Chul Park, Hyung Soo Ahn, Tae Gong Kim
J Korean Fract Soc 2007;20(2):135-140.   Published online April 30, 2007
DOI: https://doi.org/10.12671/jkfs.2007.20.2.135
AbstractAbstract PDF
PURPOSE
To compare retrospectively the antegrade and retrograde nailing in the management of ipsilateral femoral neck and shaft fractures.
MATERIALS AND METHODS
Thirty-two patients (thirty-three injuries) were included in this study. Mean age of patients was 38 years-old in the antegrade nailing group (16 injuries) and 44 years-old in the retrograde nailing group (17 injuries). We compared the union of fractures and complications between two groups, and investigated the influencing factors.
RESULTS
Femoral shaft fracture was united in 10 cases (63%) of antegrade group and 12 cases (71%) of retrograde group, at 28.2 and 27.3 weeks respectively. Nonunion was more prevalent in Winquist-Hansen III and IV (5 in antegrade nailing, 3 in retrograde nailing) than I and II. Femoral neck fracture was united with 1 case of nonunion in each group. Nonunion developed from Garden stage IV, but fractures of Garden stage I and II united regardless of methods.
CONCLUSION
In ipsilateral femoral neck and shaft fractures, the kinds of methods did not affect the results of shaft fractures. Minimally displaced neck fractures also were not influenced by kinds of methods, but retrograde nailing may have a benefit in fixing the displaced neck fractures

Citations

Citations to this article as recorded by  
  • Surgical management of bifocal femoral fractures: a systematic review and pooled analysis of treatment with a single implant versus double implants
    J. D. Cnossen, Esther M. M. Van Lieshout, Michael H. J. Verhofstad
    Archives of Orthopaedic and Trauma Surgery.2023; 143(10): 6229.     CrossRef
  • Retrograde Intramedullary Nailing or the Treatment of Segmental Femoral Shaft Fracture Including Distal Part
    Jong-Ho Yoon, Byung-Woo Ahn, Chong-Kwan Kim, Jin-Woo Jin, Ji-Hoon Lee, Hyun-Ku Cho, Joo-Hyun Lee
    Journal of the Korean Fracture Society.2009; 22(3): 145.     CrossRef
  • The Treatment of IM Nailing of Femoral Shaft Fracture: Piriformis Fossa versus Trochanteric Entry Portal
    Hyun Kook Youn, Oog Jin Shon, Dong Sung Han
    Journal of the Korean Fracture Society.2008; 21(3): 200.     CrossRef
  • 147 View
  • 1 Download
  • 3 Crossref
Close layer
Minimally Invasive Plate Osteosynthesis for Comminuted Subtrochanteric Fracture of the Femur
Chang Wug Oh, Jong Keon Oh, Sung Jung Kim, Shin Yoon Kim, Seung Hoon Baek, In Ho Jeon, Poong Taek Kim, Sang Won Lee
J Korean Fract Soc 2006;19(4):407-411.   Published online October 31, 2006
DOI: https://doi.org/10.12671/jkfs.2006.19.4.407
AbstractAbstract
PURPOSE
To evaluate the outcomes of patients with comminuted subtrochanteric femoral fractures using minimally invasive plate osteosynthesis (MIPO) technique.
MATERIALS AND METHODS
Twelve patients with a mean age of 38.2 years, who sustained comminuted subtrochanteric femoral fractures, were treated using MIPO technique. All patients suffered these fractures either from traffic accidents (6) or falls from height (6). Average follow-up was 4.3 years (range, 29~78 months). Patients were assessed radiographically and clinically with regards to time to union, malunion, and complications. According to the Seinsheimer's classification, there were 1 type III, 7 type IV, and 4 type V. Type C fractures were ten according to AO-OTA classification.
RESULTS
Union was achieved in 7 of 12 cases, in an average of 23.4 weeks (range, 12~42 weeks). Three definite non-unions with implant failures, needed the procedure of implant change and bone graft. In other two patients, early bone graft was performed for anticipated nonunion of comminuted area. The most common complication was metal failures (2 plate failures and 3 screw breakages). Limb length shortening of 1.5 cm occurred in one patient, and external rotation malunion of 15 degrees was noted in one patient. No patients developed infection.
CONCLUSION
Preserving biology of the fracture fragments, the use of MIPO technique using DCS has proven to be less successful in comminuted subtrochanteric fractures, comparing to fractures in other areas. To avoid mechanical failure, the careful and protective weight bearing is needed until the callus-bridging is seen in the commniuted area.

Citations

Citations to this article as recorded by  
  • Minimally Invasive Plate Osteosynthesis for Femoral Mid-Diaphyseal Fractures
    Hyoung-Keun Oh, Suk-Kyoo Choo, Jong-In Kim, Sung-Jong Woo
    Journal of the Korean Fracture Society.2013; 26(2): 140.     CrossRef
  • Fixation of the Femoral Subtrochanteric Fracture with Minimally Invasive Reduction Techniques
    Chul-Hyun Park, Chul-Wung Ha, Sang-Jin Park, Min-Su Ko, Oog-Jin Shon
    Journal of the Korean Fracture Society.2013; 26(2): 112.     CrossRef
  • Minimally Invasive Plate Osteosynthesis of Subtrochanteric Femoral Fractures
    Chang-Wug Oh
    Journal of the Korean Fracture Society.2009; 22(2): 123.     CrossRef
  • What is an Ideal Treatment?
    Chang-Wug Oh
    Journal of the Korean Fracture Society.2008; 21(4): 347.     CrossRef
  • 159 View
  • 0 Download
  • 4 Crossref
Close layer
Radiological Landmarks for the Assessment of the Alignment in the Use of the LCP-PLT (Locking Compression Plate-Proximal Lateral Tibia): An Anatomical and Radiological Study
Jong Keon Oh, Chang Wug Oh, Kwon Jae Roh, Hoon Sang Sohn
J Korean Fract Soc 2006;19(4):477-481.   Published online October 31, 2006
DOI: https://doi.org/10.12671/jkfs.2006.19.4.477
AbstractAbstract
PURPOSE
To evaluate the conformity of the anatomically pre-shaped LCP-PT to the tibias of the Korean adult and to identify radiological guidelines to assist intraoperative assessment of correct alignment.
MATERIALS AND METHODS
30 adult femur obtained from the Korean adult cadaver were used. A nine or eleven-hole LCP-DF was applied to the lateral surface of the tibia according to the contour. Then the distance from the inner surface of the plate to the lateral condyle was measured at the sites of mismatch. The angle between the most proximal screw and the articular surface was measured with the image intensifier.
RESULTS
The LCP-PT showed good conformity to the tibia in general. The distance from the inner surface of the plate to the lateral condyle was 3.5mm in average (range 0~9). The angle between the most proximal locking screw and the joint line was 1.16 degrees in average (range 0~7 degree).
CONCLUSION
The LCP-PT showed good conformity to the tibia in general. Malposition of the most proximal screw which is not paralleling to the joint line may herald a coronal plane malalignment.
  • 119 View
  • 0 Download
Close layer
Treatment of Complex Tibial Plateau Fractures: A Modified Patient Positioning for the Combined Anterior and Posterior Approaches
Jong Keon Oh, Chang Wug Oh, Seung Beom Hahn, Kwon Jae Roh, Kwan Hee Lee
J Korean Fract Soc 2006;19(3):396-400.   Published online July 31, 2006
DOI: https://doi.org/10.12671/jkfs.2006.19.3.396
AbstractAbstract
We have treated thirteen complex plateau fractures involving both condyles with one of the following conditions with the use of the combined anterior and posterior approaches in a modified supine position. Associated PCL avulsion fracture, displacement of major fracture plane dominantly at the back, large coronal fracture fragment involving medial or lateral condyles. A patient is placed on an operation table in supine position with a bump under the contralateral buttock. The well leg is placed in a lithotomy position and the injured leg is placed over a sterilized Mayo stand separately. For the posterior approach the table was tilt toward the injured side with the hip abducted and rotated externally. With a modified patient's positioning we were able to use combined anterior and posterior approaches simultaneously for the management of certain complex plateau fractures without changing the draping.

Citations

Citations to this article as recorded by  
  • Current Concepts in Management of Tibia Plateau Fracture
    Sang Hak Lee, Kang-Il Kim
    Journal of the Korean Fracture Society.2014; 27(3): 245.     CrossRef
  • 162 View
  • 0 Download
  • 1 Crossref
Close layer
Stripping of the Hexagonal Recess in the Process of LCP (Locking Compression Plate) Removal
Jong Keon Oh, Chang Wug Oh, Hoon Jung, Kwon Jae Roh, Tae Ho Kim
J Korean Fract Soc 2006;19(2):283-287.   Published online April 30, 2006
DOI: https://doi.org/10.12671/jkfs.2006.19.2.283
AbstractAbstract
PURPOSE
To report the difficulties in the process of locking head screw removal due to the stripping of the hexagonal recess of the screw head.
MATERIALS AND METHODS
We have removed 113 5.0-self tapping locking head screws and 202 3.5-self tapping locking head screws from 34 patients with fracture healing and 5 patients complicated with infection. All of the operations were done by one surgeon. All the screws were placed with the use of torque limiting attachment or driver.
RESULTS
All of 113 5.0-self tapping locking head screws were removed without difficulties with an usual manner. 21 out of 202 3.5-self tapping locking head screws were removed with many difficulties due to the stripping of the hexagonal recess. 3 screws were removed successfully with the use of conical extraction screw. 12 screws were taken out by further stripping and destruction of the screw head. In 6 situations where the only one screw was left stripped, the plate was bent around the stripped screw and then it was removed by turning the plate as a handle. One screw was removed with the partial breakage of the near cortex upon lifting the plate after failed attempt of using conical extraction screw.
CONCLUSION
Although we have followed the guidelines at the time of insertion we have experienced difficulties in the removal of 3.5 locking head screws due to the stripping of the hexagonal recess. Care should be taken at the time of removal of the locking plate especially for the 3.5 locking screws.

Citations

Citations to this article as recorded by  
  • An inexpensive and rapid method for removal of multiple stripped locking screws following locking plating: A case report
    Won Ro Park, Jae Hoon Jang
    International Journal of Surgery Case Reports.2019; 57: 134.     CrossRef
  • Factors affecting accurate drill sleeve insertion in locking compression plates
    J.-J. Kim, J.-W. Kim, H.-S. Yu, H.-S. Lee, H.-K. Oh
    Orthopaedics & Traumatology: Surgery & Research.2013; 99(7): 823.     CrossRef
  • Pitfalls and Complications in the Application of the Locking Plate
    Jong-Keon Oh
    Journal of the Korean Fracture Society.2007; 20(4): 355.     CrossRef
  • 163 View
  • 0 Download
  • 3 Crossref
Close layer
Conformity of the LCP-DF (Locking Compression Plate-Distal Femur) in Korean Adult Femur: A Cadaver Study
Jong Keon Oh, Chang Wug Oh, Sun Hwa Park, Kwon Jae Roh, Chang Won Jeong
J Korean Fract Soc 2005;18(4):399-404.   Published online October 31, 2005
DOI: https://doi.org/10.12671/jkfs.2005.18.4.399
AbstractAbstract PDF
PURPOSE
To evaluate the conformity of the anatomically pre-shaped LCP-DF to the femurs of the Korean adult.
MATERIALS AND METHODS
67 adult femur obtained from the Korean adult cadaver were used. An eleven-hole LCP-DF was applied to the lateral surface of the distal femur according to the contour. Then the distance from the inner surface of the plate to the cortex was measured at the sites of mismatch. The angle between the distal most screw and the articular surface was measured.
RESULTS
Mismatch was found at the level of proximal 4~5 holes of the plate with an average distance of 9.58 mm (0~18) at the tip of the plate. Otherwise, the overall conformity of the LCP-DF was excellent. The distal most screws are positioned such that the joint line is 3 degrees of valgus to this screw in average (range 0~18).
CONCLUSION
It may be necessary to consider to bend the plate in case of mismatch at the tip especially for the plate longer than 9-hole plate. The angular relation between the distal most screw and the joint line can assist the judgement for the coronal plane alignment.

Citations

Citations to this article as recorded by  
  • Comparison of Results of Minimally Invasive Plate Osteosynthesis according to Types of Locking Plate in Distal Femoral Fractures
    Oog Jin Shon, Moon Soo Kwon, Chul Hyun Park
    Journal of the Korean Fracture Society.2012; 25(4): 269.     CrossRef
  • Repeated Metal Breakage in a Femoral Shaft Fracture with Lateral Bowing - A Case Report -
    Dong Soo Kim, Yong Min Kim, Eui Sung Choi, Hyun Chul Shon, Kyoung Jin Park, Byung Ki Cho, Ji Kang Park, Hyun Cheol Lee, Kyung Ho Hong
    Journal of the Korean Fracture Society.2012; 25(2): 136.     CrossRef
  • Axial Malalignment after Minimally Invasive Plate Osteosynthesis in Distal Femur Fractures with Metaphyseal Comminution
    Jae-Ho Jang, Gu-Hee Jung, Jae-Do Kim, Cheung-Kue Kim
    Journal of the Korean Orthopaedic Association.2011; 46(4): 326.     CrossRef
  • Treatment of Distal Femoral Fractures Using Polyaxial Locking Plate
    Sang-Eun Park, Hyun-Taek Kang, Young-Yul Kim, Jae-Jung Jeong, Jung-U Lee, Weon-Yoo Kim
    Journal of the Korean Fracture Society.2011; 24(4): 321.     CrossRef
  • Pitfalls and Complications in the Application of the Locking Plate
    Jong-Keon Oh
    Journal of the Korean Fracture Society.2007; 20(4): 355.     CrossRef
  • 139 View
  • 0 Download
  • 5 Crossref
Close layer
Treatment of Complex Tibial Plateau Fractures
Jong Keon Oh
J Korean Fract Soc 2005;18(3):349-358.   Published online July 31, 2005
DOI: https://doi.org/10.12671/jkfs.2005.18.3.349
AbstractAbstract PDF
No abstract available.

Citations

Citations to this article as recorded by  
  • Current Concepts in Management of Tibia Plateau Fracture
    Sang Hak Lee, Kang-Il Kim
    Journal of the Korean Fracture Society.2014; 27(3): 245.     CrossRef
  • Analysis of Risk Factors for the Posterolateral Articular Depression and Status of Posterolateral Fragment in Lateral Condylar and Bicondylar Tibial Plateau Fractures with Joint Depression
    Jung-Yun Choi, Yong-Woon Shin, Beom-Jung Lee
    Journal of the Korean Fracture Society.2013; 26(4): 241.     CrossRef
  • Dual Plate Fixation Compared with Hybrid External Fixator Application for Complex Tibial Plateau Fractures
    Jae-Sung Lee, Yong-Beom Park, Han-Jun Lee
    Journal of the Korean Fracture Society.2008; 21(2): 124.     CrossRef
  • 101 View
  • 1 Download
  • 3 Crossref
Close layer
Double Plating of Proximal Tibial Fractures Using Minimally Invasive Percutaneous Osteosynthesis Technique
Chang Wug Oh, Jong Keon Oh, In Ho Jeon, Hee Soo Kyung, Il Hyung Park, Byung Chul Park, Woo Kie Min, Ji Ho Lee
J Korean Fract Soc 2005;18(3):250-255.   Published online July 31, 2005
DOI: https://doi.org/10.12671/jkfs.2005.18.3.250
AbstractAbstract PDF
OBJECTIVES
To evaluate the results and its efficacy of double plating for proximal tibial fractures using minimally invasive percutaneous osteosynthesis (MIPO) technique. MATERIAL & METHODS: Twenty-three fractures, followed-up more than 1 year, were included in this retrospective study. There were 18 men and 5 women, and the mean age was 53.5 years-old. According to the AO-OTA classification, five were 41A, 13 were 41C, and 5 were 42. There were four open fractures (grade I- three, grade III A-one case). The plates were fixed on the medial and lateral sides of tibia with MIPO technique. Functional and radiographic results were evaluated by the modified Rasmussen system.
RESULTS
All fractures healed without bone graft, and the mean period for fracture healing was 19.3 weeks (range, 10~32 weeks). All other patients had excellent or good clinical or radiological results, except for two patients of a fair clinical result after a combined injury. Complications included one case of shortening (1 cm) and two cases of mal-alignments (varus less than 10 degrees). There was one case of superficial infection, but no patient showed deep infection.
CONCLUSION
Double plating using MIPO technique can provide favorable results in the treatment of proximal tibial fractures.

Citations

Citations to this article as recorded by  
  • Medial Minimally Invasive Percutaneous Plate Osteosynthesis in Proximal Tibial Comminuted Fractures
    Jae-Ang Sim, Kwang-Hui Kim, Yong-Seuk Lee, Sang-Jin Lee, Beom-Koo Lee
    Journal of the Korean Orthopaedic Association.2014; 49(4): 278.     CrossRef
  • Minimally Invasive Plate Osteosynthesis for Proximal Tibial Shaft Fracture
    Young-Soo Byun, Ki-Chul Park, Hyun-Jong Bong, Chang-Hoon Lee
    Journal of the Korean Fracture Society.2011; 24(1): 23.     CrossRef
  • Treatment of Proximal Tibia Fractures Using LCP by MIPO Technique
    Sang-Ho Ha, Dong-Hui Kim, Jun-Young Lee
    Journal of the Korean Fracture Society.2010; 23(1): 34.     CrossRef
  • Staged Minimally Invasive Plate Osteosynthesis of Proximal Tibial Fracture
    Joon-Woo Kim, Chang-Wug Oh, Jong-Keon Oh, Hee-Soo Kyung, Woo-Kie Min, Byung-Chul Park, Kyung-Hoon Kim, Hee-Joon Kim
    Journal of the Korean Fracture Society.2009; 22(1): 6.     CrossRef
  • 178 View
  • 2 Download
  • 4 Crossref
Close layer
A Biomechanical Advantage of the Lengthening with an External Fixator Over an Intramedullary Nail: An Experimental Study in Saw Bones and Cadeveric Bones
Chang Wug Oh, Poong Taek Kim, Hae Ryong Song, Jong Keon Oh, Hyung Soo Ahn, Byung Chul Park, Byung Guk Min, Sung Ki Park, Young Heon Sohn
J Korean Fract Soc 2005;18(3):335-340.   Published online July 31, 2005
DOI: https://doi.org/10.12671/jkfs.2005.18.3.335
AbstractAbstract PDF
PURPOSE
To know biomechanical differences in methods of limb lengthening between using monolateral external fixator and using external fixator over an intramedullary nail.
MATERIALS AND METHODS
In acryl rods, saw-bone, and cadeveric bone, we created two lengthening models of using monolateral external fixator and using external fixator over an intramedullary nail. The axial compression test was done on the site of osteotomy for lengthening. To fix the models, half pins of 5 mm in diameter and nails of 9 mm in diameter were used. Using MTS (Material Test System) machine, we evaluated the differences of axial stiffness according to the presence of an intramedullary nail or the numbers of half-pins which were fixed at each side of osteotomy.
RESULTS
Lengthening over an intramedullary nail, comparing to monolateral external fixator only, increased the axial stiffness by 1.1~1.2 times in acryl rods, 1.2~1.6 times in saw bones, and 15.6~15.9 times in cadeveric bones when the same numbers of half-pins were used. In saw bone and cadaveric bone, the group of two half pins in lengthening over an intramedullary nail was stiffer than the group of three pins in lengthening with monolateral external fixator.
CONCLUSION
In the distraction of the limb, the addition of an intramedullary nail may increase the axial stiffness of the frame of monolateral external fixator. In lengthening over an intramedullary nail, it is enough to distract the bone with fixing two half pins at each sides of osteotomy.
  • 143 View
  • 0 Download
Close layer
Management of Ipsilateral Femur and Tibia Fractures, with Retrograde and Antegrade Nailings from the Knee
Chang Wug Oh, Jong Keon Oh, Woo Kie Min, In Ho Jeon, Hyung Soo Ahn, Hee Soo Kyung, Poong Taek Kim, Jung Ho Noh
J Korean Fract Soc 2005;18(2):131-135.   Published online April 30, 2005
DOI: https://doi.org/10.12671/jkfs.2005.18.2.131
AbstractAbstract PDF
PURPOSE
To review the results in the management of ipsilateral femur and tibia fractures, using femoral and tibial intramedullary nailings with single incision on the knee.
MATERIALS AND METHODS
We treated 19 cases of ipsilateral femur and tibia fractures (floating knee), and the retrograde femoral nailing and antegrade tibial nailing were done with single incision on the knee. Except one patient of early death, 18 patients were included in this study. The mean age of index procedure was 34.1 years, and all of them had follow-up study for a mean of 2.4 years. The mean injury severity score was 18.8, and 12 patients had other fractures in the lower extremity.
RESULTS
Primary union was achieved in all, but one patient of femur and two of tibia. The average period for union was 27.6 weeks for femur and 24.5 weeks for tibia. One femoral nonunion occurred due to the metal failure after using short nail, and two tibial nonunion were caused by the bone loss with open tibial fractures. Most patients showed no limitation in knee motion. According to Karlstrom-Olerud criteria, functional results showed 14 excellent, 3 good and 1 acceptable. The protrusion of nail tip into the knee joint made the acceptable result with moderate limitation of knee motion, but it improved after the removal of nail.
CONCLUSION
CONCLUSION: Simultaneous retrograde femoral and antegrade tibial nailing with single incision on the knee, with an appropriate technique, can achieve the satisfactory result in the management of the ipsilateral femur and tibia fractures.

Citations

Citations to this article as recorded by  
  • Ipsilateral Femoral Segmental and Tibial Fractures: A Case Report
    Oog Jin Sohn, Chul Hyun Park, Sang Keun Bae
    Journal of the Korean Fracture Society.2009; 22(3): 193.     CrossRef
  • 152 View
  • 1 Download
  • 1 Crossref
Close layer
Treatment of Open Tibial Shaft Fractures using Unreamed Nailing
Jong Keon Oh, Chang Wug Oh, Kwon Jae Roh, Duk Moon Chung
J Korean Fract Soc 2005;18(1):22-28.   Published online January 31, 2005
DOI: https://doi.org/10.12671/jkfs.2005.18.1.22
AbstractAbstract PDF
PURPOSE
To report the results of unreamed nailing using a nail with the largest possible diameter for the management of the open tibial shaft fractures.
MATERIALS AND METHODS
Nineteen patients with open tibial shaft fractures underwent unreamed nailing with the largest possible diameter according to the isthmic diameter measured on preoperative radiography. There were 1 Grade I, 6 Grade II, 9 Grade IIIa, 3 Grade IIIb open fractures. There were 4 type A, 12 type B, 3 type C fractures according to the OTA classification. Fractures were classified as The nail was introduced after gentle passage of a 7 to 8 millimeter-hand reamer.
RESULTS
Union was obtained in all cases. However 9 (47%) fractures required an additional procedures before union. In 6 cases, dynamization was done. Two of them were required exchange nailing for nonunion, 1 of two gained bony union through additional bone graft. Three of the others had gained union through exchange nailing, bone graft, bone transport respectively. There were one rotational malunion, one superfical and one deep infection. Interlocking screw breakage developed only in one patient.
CONCLUSION
Our data indicate that unreamed nailing in the management of open tibial fractures is safe and reliable method. Using a tight fitting nail with the largest possible diameter is a safe and effective way to avoid the problems of screw breakage.

Citations

Citations to this article as recorded by  
  • Treatment of Type IIIb Open Tibial Fractures
    Seong Yeon Lim, Il Jae Lee, Jae Ho Joe, Hyung Keun Song
    Journal of the Korean Fracture Society.2014; 27(4): 267.     CrossRef
  • Management of Open Tibial Fractures: Role of Internal Fixation
    Yerl-Bo Sung
    Journal of the Korean Fracture Society.2007; 20(4): 349.     CrossRef
  • 180 View
  • 0 Download
  • 2 Crossref
Close layer
Minimally Invasive Percutaneous Plate Stabilization of Proximal Tibial Fractures
Chang Wug Oh, Jong Keon Oh, In Ho Jeon, Hee Soo Kyung, Il Hyung Park, Joo Chul Ihn, Yeon Ki Woo, Ho Sung Jung
J Korean Fract Soc 2004;17(3):224-229.   Published online July 31, 2004
DOI: https://doi.org/10.12671/jkfs.2004.17.3.224
AbstractAbstract PDF
PURPOSE
Despite of various treatment methods, proximal tibial fractures are common injuries that may be associated with poor outcomes and high rates of complications. To improve this, percutaneous plating technique was performed in the proximal tibial fractures.
MATERIALS AND METHODS
Twenty-four proximal tibial fractures (AO 41A; 5, AO 41C; 12, AO 42; 7) were treated by percutaneous plating with either or both sides without bone graft. One was open fracture.
RESULTS
All fractures were healed. The average time for fracture healing was 16.5 weeks (range, 8~24 weeks). Complications included a 1cm shortened case and two mal-alignments; a 6 degree valgus case and 5 degree varus case. There was one case of superficial infection, which healed after plate removal. But, there was no deep infection. Results were evaluated by modified Rasmussen score system, all patients had excellent or good result.
CONCLUSION
Minimally invasive percutaneous plating technique can provide favorable results in the treatment of proximal tibial fractures.

Citations

Citations to this article as recorded by  
  • MINIMALLY INVASIVE OSTEOSYNTHESIS WITH PLATE OR NAIL FOR META-DIAPHYSEAL TIBIAL FRACTURES - WHAT IS BETTER?
    B. Makelov
    Trakia Journal of Sciences.2023; 21(4): 357.     CrossRef
  • Medial Minimally Invasive Percutaneous Plate Osteosynthesis in Proximal Tibial Comminuted Fractures
    Jae-Ang Sim, Kwang-Hui Kim, Yong-Seuk Lee, Sang-Jin Lee, Beom-Koo Lee
    Journal of the Korean Orthopaedic Association.2014; 49(4): 278.     CrossRef
  • Minimally Invasive Percutaneous Plate Stabilization Using a Medial Locking Plate for Proximal Tibial Fractures - Technical Note -
    Jae Ang Sim, Beom Koo Lee, Kwang Hui Kim, Yong Seuk Lee
    Journal of the Korean Fracture Society.2013; 26(4): 327.     CrossRef
  • Clinical Outcomes of Locking Compression Plate Fixation through Minimally Invasive Percutaneous Plate Osteosynthesis in the Treatment of Distal Tibia Fracture
    Jae-Sung Yoo, Hyun-Woo Park
    Journal of the Korean Fracture Society.2012; 25(2): 117.     CrossRef
  • Minimally Invasive Plate Osteosynthesis for Proximal Tibial Shaft Fracture
    Young-Soo Byun, Ki-Chul Park, Hyun-Jong Bong, Chang-Hoon Lee
    Journal of the Korean Fracture Society.2011; 24(1): 23.     CrossRef
  • Minimally Invasive Plate Osteosynthesis for the Upper Extremity Fracture Using a Lumbar Spreader - Surgical Technique -
    Gu-Hee Jung, Chyul-Hyun Cho, Jae-Do Kim
    Journal of the Korean Fracture Society.2011; 24(1): 83.     CrossRef
  • Management of Fractures of Distal Tibia by Minimally Invasive Plate Osteosynthesis through an Anterior Approach
    Gu-Hee Jung, Jae-Do Kim, Jae-Ho Jang, Sung-Keun Heo, Dong-won Lee
    Journal of the Korean Orthopaedic Association.2010; 45(6): 473.     CrossRef
  • The Comparison of Minimally Invasive Plate Osteosynthesis and Intramedullary Nailing in the Treatment of the Proximal and Distal Tibia Fracture
    Joon Soon Kang, Seung Rim Park, Sang Rim Kim, Yong Geun Park, Jae Ho Jung, Sung Wook Choi
    Journal of the Korean Fracture Society.2010; 23(2): 172.     CrossRef
  • Staged Minimally Invasive Plate Osteosynthesis of Proximal Tibial Fracture
    Joon-Woo Kim, Chang-Wug Oh, Jong-Keon Oh, Hee-Soo Kyung, Woo-Kie Min, Byung-Chul Park, Kyung-Hoon Kim, Hee-Joon Kim
    Journal of the Korean Fracture Society.2009; 22(1): 6.     CrossRef
  • Proximal Tibia Fracture: Plating
    Ki-Chul Park
    Journal of the Korean Fracture Society.2009; 22(3): 206.     CrossRef
  • 143 View
  • 2 Download
  • 10 Crossref
Close layer
Biomechanical Analysis of Hybrid External Fixation for the Distal Tibial Fractures: A FEM Study
Duk Young Jung, Boug Ju Kim, Seok Bae Ryu, Jong Keon Oh
J Korean Fract Soc 2004;17(2):160-166.   Published online April 30, 2004
DOI: https://doi.org/10.12671/jkfs.2004.17.2.160
AbstractAbstract PDF
PURPOSE
To analyze the biomechanical effects of different frame configurations of the hybrid external fixators for distal tibial fractures on the frame stiffness and stress distribution with a finite element method (FEM).
MATERIALS AND METHODS
Five configurations were simulated: Group I: two wires with convergence angle of 60degrees, Group II: 3rd wire on a bisector axis of the group I. Group III: two wires with 30degrees. Group IV: 3rd wire on a bisector axis. Group V: two wires with 30degree and a half pin on the distal articular fragment. Each group was simulated under compression, torsion, anterior-posterior and lateral-medial bending load. Stiffness, stress and deformation values were calculated.
RESULTS
The overall stiffness was increased by 15~30% with the addition of a third wire, and by 150~400% with a anteromedial half pin on the articular fragment. The half pin decreased the stress level of the frame by about 43% and the deformation of the 5/8 ring by about 30%.
CONCLUSION
The addition of a half pin on the articular fragment is not only a method of increasing the stiffness but also a way of decreasing the stress concentration and the deformation of the frame.
  • 123 View
  • 0 Download
Close layer
Radiologic Evaluation for the Safe Zone of Percutaneous Iliosacral Screw Fixation
Jong Keon Oh, Su Young Bae, Jong Oh Kim, Kwon Jae Roh, Jeong Joon Lee, Sang Yeol Chang
J Korean Soc Fract 2002;15(3):336-341.   Published online July 31, 2002
DOI: https://doi.org/10.12671/jksf.2002.15.3.336
AbstractAbstract PDF
PURPOSE
To evaluate the correlation of the safe zone of percutaneous iliosacral screw fixation with sacral dysmorphism and sacral alar slope variation.
MATERIALS AND METHODS
We studied the plain radiographs and the pelvic bone CT images of 52 patients. We reviewed each cases in terms of Routt 's dysmorphism and sacral alar slope variation(anterior, coplanar and posterior to inter-ICD line). We divided each cases into narrow and wide groups by the width of safe zone for the transverse 6.5mm cannulated cancellous screw. The data were analysed by McNemar x2-test and Cochran Q-test(p<0.05).
RESULTS
Typical sacral dysmorphism was found in five cases(9%). Four cases with dysmorphism(80%) and eighteen non-dysmorphic cases(38.2%) revealed narrow safe zones. The sacral slopes were anterior in 16 cases, coplanar in 25 cases, and posterior in 11 cases. The safe zone was significantly narrow in the group with anterior slope variation.
CONCLUSION
We could not found definite correlation between sacral dysmorphism and a narrow safe zone because the incidence of dysmorphism was too low in our study which differed from Routt 's report. An anterior sacral alar slope on CT can be a significant risk indicator for potential narrow safe zone and the risk of screw malposition.

Citations

Citations to this article as recorded by  
  • Measurement of Optimal Insertion Angle for Iliosacral Screw Fixation Using Three-Dimensional Computed Tomography Scans
    Jung-Jae Kim, Chul-Young Jung, Jonathan G. Eastman, Hyoung-Keun Oh
    Clinics in Orthopedic Surgery.2016; 8(2): 133.     CrossRef
  • Operative Treatment of Unstable Pelvic Ring Injury
    Sang Hong Lee, Sang Ho Ha, Young Kwan Lee, Sung Won Cho, Sang Soo Park
    Journal of the Korean Fracture Society.2012; 25(4): 243.     CrossRef
  • Upper Sacral Morphology Related to Iliosacral Screw Fixation in Korean
    Jung-Jae Kim, Chul-Young Jung, Hyoung-Keun Oh, Byoung-Se Yang, Jae-Suck Chang
    Journal of the Korean Fracture Society.2007; 20(2): 115.     CrossRef
  • 164 View
  • 0 Download
  • 3 Crossref
Close layer
The Biomechanics of Hybrid External Fixator: The Effect of Periarticular Half Pin on Frame Stiffness
Jong Keon Oh, Duk Young Jung, In Su Kim
J Korean Soc Fract 2002;15(2):114-122.   Published online April 30, 2002
DOI: https://doi.org/10.12671/jksf.2002.15.2.114
AbstractAbstract PDF
OBJECTIVES
The purpose of this study was to identify the biomechanical effect of periarticular half pin in the hybrid external fixator.
METHODS
Simulated tibial plateau fractures were created using a polyvinylchloride pipe. Seven frame configurations were tested : a four-ring Ilizarov frame, a hybrid frame with three wires on peri-articular fragment, hybrid frames with wires and half pins on peri-articular fragment by four different configurations, a hybrid frame constructed with multiple levels of fixation in the periarticular fragment. A materials testing machine was used to apply pure compression, anterior and posterior bending, medial and lateral bending, and torsion. Stiffness values were calculated from the load deformation and torque angle curves RESULTS: The overall stiffness of the hybrid frame was increased up to 30% by replacing a coronal tension wire with a half pin placed on the sagittal plane. The hybrid frame constructed with two wires and a half pin on the sagittal plane of the periarticular fragment showed overall stiffness compatible with that of multi-level peri-articular fixation frame.
CONCLUSION
Our results show that the half pin placed on the periarticular fragment can be a effective tool to increase the stiffness of hybrid external fixators in this periarticular tibia fracture model.
  • 136 View
  • 1 Download
Close layer
The Biomechanics of Hybrid External Fixator: Effectiveness of Bar to Ring Connection
Jong Keon Oh, Duk Young Jung, Seong Yong Yoon
J Korean Soc Fract 2001;14(4):783-791.   Published online October 31, 2001
DOI: https://doi.org/10.12671/jksf.2001.14.4.783
AbstractAbstract PDF
OBJECTIVES
The biomechanical effects of bar to ring connection in a hybrid external fixator have not yet been clearly identified. The purpose of this study was to identify the biomechanical effects of bar to ring augmentation in the hybrid external fixator.
METHODS
Simulated tibial plateau fractures were created using a polyvinylchloride pipe. Groups of simulated periarticular tibia fractures were stabilized with one of six different external fixation constructs with components from one manufacturer. Six frame configurations were tested: a four-ring Ilizarov frame, a hybrid frame without bar to ring augmentation, hybrid frames with three different bar to ring augmentations, a hybrid frame constructed with multiple levels of fixation in the periarticular fragment. A material testing machine was used to apply pure compression, anterior and posterior bending, medial and lateral bending, and torsion. Stiffness values were calculated from the load deformation and torque angle curves RESULTS: The four-ring Ilizarov fixator was the stiffest in all modes of testing. Frame augmentation with three different types of bar-to-ring connection did increase stiffness in all modes of testing. No statistical difference was found between the stiffness of the frames with three different types of bar to ring augmentations. The stiffness of a hybrid frame constructed with multiple levels of fixation in the periarticular fragment was comparable to that of the fixators with bar to ring augmentation.
CONCLUSION
Our results show that the bar to ring augmentation increases the overall stiffness of hybrid external fixators in this periarticular tibia fracture model by 27-76%.
  • 81 View
  • 0 Download
Close layer
Brooker Intramedually Nailing for the Treatment of Distal 1/3 Tibial Fractures with Compromised Soft Tissue
Chung Nam Kang, Jong Oh Kim, Yeo Hon Yun, Dong Wook Kim, Young Do Koh, Jae Doo Yoo, Jong Keon Oh, Ki Woong Lee
J Korean Soc Fract 1999;12(4):924-931.   Published online October 31, 1999
DOI: https://doi.org/10.12671/jksf.1999.12.4.924
AbstractAbstract PDF
The treatment of distal tibial fractures with compromised soft tissue poses many problems that usually occurs from the high-energy trauma, and the results are often unsatisfactory following lots of complications like loss of reduction, malunion, and inlection. We studied to evaluate the treatment results of Brooker intramedually nailing for the distal 1/3 tibial fractures with compromised soft tissue. Twenty-three cases of distal tibial fractures with comprolnised soft tissue were reviewed and we analyzed the results of surgical treatment in the viewpoint of union time, loss of reduction, malunion, complication and its final outcome. The range of follow-up was 24 months to 38 months with mean 29 months follow-up. Most of patients were between twenty and sixty years, and average age was 43.2 years. Acording to Gustilo and Andersons classification, 3 were Type I, 2 were Type II of 5 open fractures. According to Tschernes classification, 13 were Grade I, 5 were Grade II of 18 closed fractures. The average to union was 15 weeks with range 11 to 20 weeks. The healing was slowest in Tschernes Type II and fastest in Tschernes Type I fracture. There were 3 cases of malunion, more than 5 degrees. All of the 3 cases were posterior angulation. Only 1 case was the loss of reduction. This case was 3 to 10 degrees of varus angulation. There were 3 cases of superficial infection. The infection was controlled with antibiotic therapy. Only 1 case was acceptable of the final outcome. This case waf limping gait because of pain and loss of ankle dorsiflexion to 15 degrees. But, the limitation of ordinary work was not seen. And 18 cases were excellent and 4 cases were good. We recommand that wherever possible, Brooker intramedually nailing can be used for distal tibial fractures with compromised soft tissue. And a high rate of union and a low rate of complication can be expected with thit treatment modality.
  • 63 View
  • 0 Download
Close layer
Fracture-separation of the Distal Humeral Epiphysis in Children
Yeo Hon Yun, Jong Keon Oh
J Korean Soc Fract 1998;11(4):977-984.   Published online October 31, 1998
DOI: https://doi.org/10.12671/jksf.1998.11.4.977
AbstractAbstract PDF
We retrospectively reviewed twelve cases of the fracture-separation of the distal humeral epiphysis, which were treated during the period from 1989 to 1996. The incidence of this injury was about 3 % from 266 pediatric elbow fractures. Four cases were remained misdiagnosed as the lateral or medial humeral condylar fracture until the authors reviewed their radiographs. Though eleven fractures were extension type injury with typical posteromedial displacement, we identified a rare flexion type injury with anterolateral displacement. This case was a 12+7 year old boy, who was the oldest in our series. Cubitus varus deformity of more than 10 developed in five patients, and cubitus rectu intwo patients. One patient underwent osteotomy for the in the literature. The major problem of this fracture was the possibility of misdiagnosis. Whichever reament modality onr may choose, careful evaluation of the carrying angle after reduction is mandatory to avoid residual cubitus varus deformity.
  • 68 View
  • 0 Download
Close layer
Treatment of Type IIIB Open Tibial Shaft Fractures
Chung Nam Kang, Jong Oh Kim, Dong Wook Kim, Young Doo Koh, Jae Doo You, Jong Keon Oh, Young Seuk Kim
J Korean Soc Fract 1998;11(3):560-566.   Published online July 31, 1998
DOI: https://doi.org/10.12671/jksf.1998.11.3.560
AbstractAbstract PDF
In general, severe open fractures of the tibial shaft have been treated initially with external fixation. However, despite many refinements in this technique, it has been associated with numerous complications, including problems at the sites of pins, non-union, delayed union, malunion, and infection. The purpose of this retrospective study is to analyze the results in a consecutive series of patients. There were 8 males and 2 females with an average age of the 44.9 years(range, 26-64 years). The mean follow up period was 23.2 nibtgs(range, 34-120 days). Free flap procedures were performed on all patients. The average time between removal of the fixator and intramedullary nailing was 16.5 days(range, 11-26 days). Indication of conversion to nailing was abscence of any serous discharge, reddness or local heating around pin-sites and normal renge of laboratory data. All 10 fractures had united with additional bone graft in 7 cases. The most frequent complications were delayed union in 7 cases and infection(superficial infection: 6 cases, osteomyelitis: 1 case) after IM nailing. We concluded that pin-tract infection is the major cause of infection after IM nail, but duration of external fixation and time interval(between removal of external fixator and nailing) are not isolated factors.

Citations

Citations to this article as recorded by  
  • Study on Instant Fish Cake Noodle Manufacturing Techniques Using Ultra-fine Powdered Kelp
    Yoo-Jin Park, Se-Jong Kim, Myung-Ryun Han, Moon-Jeong Chang, Myung-Hwan Kim
    Food Engineering Progress.2019; 23(3): 217.     CrossRef
  • Treatment of Type IIIb Open Tibial Fractures
    Seong Yeon Lim, Il Jae Lee, Jae Ho Joe, Hyung Keun Song
    Journal of the Korean Fracture Society.2014; 27(4): 267.     CrossRef
  • 158 View
  • 0 Download
  • 2 Crossref
Close layer
Operative Treatment of Intraarticular Fractures of the Distal Radius
Chung Nam Kang, Jin Man Wang, Kwon Jae Roh, Jong Oh Kim, Dong Jun Kim, Jong Keon Oh, Han Cheon Bang
J Korean Soc Fract 1998;11(1):56-62.   Published online January 31, 1998
DOI: https://doi.org/10.12671/jksf.1998.11.1.56
AbstractAbstract PDF
Intraarticular fractures of the distal part of the radius comprise a distinct subgroup of fractures that are difficult to manage and are associated with a high frequency of complication and represent one of the greatest challenges to the orthopaedic surgeon. We reviewed 30 cases(28 patients) of intraarticular fractures of the distal radius treated surgically in orthopaedic department of Ewha medical center between January 1993 to May 1996 and analyzed the correlation between the clinical end results and radiographic parameters. The clinical end results were significantly worse when radia inclination didn't exceed 15, or radial length was less than 10mm or dorsal tilt exceeded 0. Ulna styloid fractre did adversely affect the clinical results. In our study 2mm articular step off did not show any difference in clinical results. But this is thought to be the result of relatively short period of follow up. Therefore we need to analyse this factor with long term follow up data.
  • 102 View
  • 0 Download
Close layer
The Operative Treatment of the shaft Fractures of the Forearm Bone: Operative Comparison in Intramedullary Fixation to Plate Fixation on Treatment of the Both Forearm Bone Fracture
Chung Nam Kang, Jong Ho Kim, Dong Wook Kim, Young Do Gho, Jae Doo You, Jong Keon Oh, Jin Chang
J Korean Soc Fract 1998;11(1):63-69.   Published online January 31, 1998
DOI: https://doi.org/10.12671/jksf.1998.11.1.63
AbstractAbstract PDF
Diaphyseal fractures of the radius and ulna present high incidence of malunion and nonunion because of difficulty in reduction and maintenence of two mobile, parallel ones in the presence of the pronating and supinating muscles which exert angulatory as well as well as rotational forces. The author divided the traceable patients into two groups, the one was the group treated with AO compression plates and the other one was the roup treated with Rush pin in radius and AO compression plate in ulna, and compared the results in the aspect of healing time and functional results. The results were as follows; 1.Those two groups were demographically similar. 2.The immobilization period and the radiologic bone union time did not differentiate two groups significantly. 3.In plate group, one nonunion, one nerve injury and two superficial wound infection were occurred. 4.Between the two operative methods selected alternatively, immobilization period, radiologic bone union and fuctional results were not different significantly, but the Rush pinning method was preferred due to simple operation technique, small operation scar, short operation time, a little blood loss, a few complication.

Citations

Citations to this article as recorded by  
  • Shaft Fractures of Both Forearm Bones: The Outcomes of Surgical Treatment with Plating Only and Combined Plating and Intramedullary Nailing
    Sang Bum Kim, Youn Moo Heo, Jin Woong Yi, Jung Bum Lee, Byoung Gu Lim
    Clinics in Orthopedic Surgery.2015; 7(3): 282.     CrossRef
  • Interlocking Intramedullary Nailing of Forearm Shaft Fractures in Adults
    Sanglim Lee, Hee-Sung Lee, Yerl-Bo Sung, Jae-Kwang Yum
    Journal of the Korean Fracture Society.2009; 22(1): 30.     CrossRef
  • 138 View
  • 1 Download
  • 2 Crossref
Close layer
Complications of Interlocking Intramedullary Nailing for the Humeral Shaft Fracture
Chung Nam Kang, Jong Oh Kim, Dong Wook Kim, Young Do Koh, Jong Keon Oh, Sang Hun Ko, Seung Wook Jeong
J Korean Soc Fract 1997;10(3):669-677.   Published online July 31, 1997
DOI: https://doi.org/10.12671/jksf.1997.10.3.669
AbstractAbstract PDF
Several advantages of intramedullary nails over plates and external fixators have led to an anpansion of the surgical indications for humeral shaft tractures. But, various morbidities due to proximity of several important structures, such as rotator cuff and radial nerve, follwed the operation. We reviewed our experience with 23 cases of humeral shaft fractures that were treated by interlocking intramedullary nailing to evaluate the pitfalls and the complications of this technique. Fifteen men and 8 women were followed for average 19.5 months. Twenty one (91.3%) of them had midshaft fractures. According to AO/ASIF classification, type A was most common(60.9%), and followed by type B(26.1%) and type C(13.O%). Eighteen of them had associated injuries - 5 radial nerve palsies, 1 Volkmans ischemic contracture, and 14 had fracture of other sites. Indications for interlocking intramedullary nailing were unsatisfactory reduction after closed reduction, fracture of the ipsilateral upper extremity, segmental fractures, and multiple injuries. The operation was performed average 6.7 days after injury. The final results were evaluated with radiographs for quality of union and with physical examination for functional status of the shoulder. There were four cases of complication associated with increase morbidity. A post operative radial verve palsy, associated with the distal interlocking screw fixation was developed due to inappropriately short nail insertion. And in one case, fracture healing was delayed due to distraction of the fracture gap after nailing. In another case subacromial impingement was developed secondary to protruded nail tip because the length was thought be the common underlying causative factor. Finally there was a case of iatrogenic fracture at the site of distal interlocking screw fixation and it was thought to be a technical problem. The results gave us the conclusion that inappropriate nail length was the common underlying causative factor of the complications. Therefore in the interlocking IM nailing for the humeral shaft fractures, accurate measurment of nail length is one of the most cirtical factor for the good final result.
  • 85 View
  • 0 Download
Close layer
Treatment of the Femur Shaft Fractures using Interlocking Nail
Jong Keon Oh, Soon Hyuck Lee, Seung Woo Suh, Young Soo Byun
J Korean Soc Fract 1997;10(2):289-294.   Published online April 30, 1997
DOI: https://doi.org/10.12671/jksf.1997.10.2.289
AbstractAbstract PDF
A series of forty patients who had forty femoral shaft fractures that were treated with static interlocking nailing were analyzed to determine the incidence of union of the fracture without planed conversion from static to dynamic intramedullary fixation as a technique to stimulate healing of the fracture. All of the forty cases were nailed using closed method under the guide of a image intensifier. The time to full weight was individualized for each patient and depend on the degree of comminution, the postoperative cortical contact between the major fragments, the presence of bridging callus as seen on follow up x-rays, and the patients mobility according to the associated injuries. Healing occurred in thirty nine(97%) of the forty fractures of the femoral shaft that had been treated with static interlocking nailing without dynamizaton. Only one patient needed conversion from static to dynamic interlocking fixation to promote fracture healing. This patient had a delayed union after closed interlocking nailing of Gustilo type I open midshaft fracture associated with Winquist type II comminution. We concluded that static interlocking nailing for femoral shaft fractures does not seem to inhibit the fracture healing process, and that conversion to dynamic intramedullary fixation is needed only for exceptional cases of delayed union.
  • 123 View
  • 1 Download
Close layer
Operative Treatment of Intraarticular Fractures of the Distal Raidus
Jong Keon Oh, Seung Woo Suh, Woo Nam Moon, Sung Joon Hong
J Korean Soc Fract 1996;9(1):1-7.   Published online January 31, 1996
DOI: https://doi.org/10.12671/jksf.1996.9.1.1
AbstractAbstract PDF
The intraarticular fracture of the distal radius is one of the most common fractures in the orthopaedic field and physicians have considered the results of the treatment to be favorable. But recently investigations into the pathomechanics of these injuries highlight the peoblems of arthritis, pain, swelling, weakness, limited ranges of motion and instability associated with nonanatomic reduction of both intraaetocular fragments and their associated ligaments. So the treatment of intraarticular fractures of the distal radius has been altered into more aggressive pattern using the open reduction and internal fixation, open reduction or closed reduction and internal fixation, closed reduction and percutaneous pinning. The authors reviewed 37 cases(34 patients)of intraarticular fractures of the distal radius treated using operative methods from February 1989 to May 1994 in the department of orthopaedic surgery, Ansan Hospital, Korea University: We analyzed the correlation between the radiologic parameters(articular conguity, radial height loss, adial angulation, palmar angulation)and the end results.
  • 84 View
  • 0 Download
Close layer

J Musculoskelet Trauma : Journal of Musculoskeletal Trauma
Close layer
TOP