Breakage of Cephalomedullary Nail Used in the Treatment of Proximal Femur Fractures: Case Report
-
Seok Hyun Kweon, Chang Hyun Shin, Jin Sung Park, Byoung San Choi
-
J Korean Fract Soc 2016;29(1):42-49. Published online January 31, 2016
-
DOI: https://doi.org/10.12671/jkfs.2016.29.1.42
-
-
Abstract
PDF
- Internal fixation using a cephalomedullary nail as treatment for proximal femur fracture has recently been popular for early ambulation and rehabilitation. However metal breakage at the lag screw insertion site was reported due to non-union, delayed-union, and early weight bearing. In our orthopedic department, we experienced 2 cases of nail breakage at the lag screw insertion site, therefore we report on evaluation of the cause of metal failure and prevention of complications with literature review.
-
Citations
Citations to this article as recorded by 
- Breakage of the Tail Portion of the Lag Screw during Removal of Proximal Femoral Zimmer Natural Nail: Report of Two Cases with Technical Notes
Asep Santoso, Ik-Sun Choi, Kyung-Soon Park, Taek-Rim Yoon Hip & Pelvis.2017; 29(3): 199. CrossRef
-
183
View
-
1
Download
-
1
Crossref
-
Percutaneous Kirschner Wire Fixation of Acute Mallet Fractures Percutaneousely Reduced by Towel Clip
-
Chung Soo Han, Duke Whan Chung, Bi O Jeong, Hyun Chul Park, Jin Young Kim, Cheol Hee Park, Jin Sung Park
-
J Korean Fract Soc 2009;22(4):283-287. Published online October 31, 2009
-
DOI: https://doi.org/10.12671/jkfs.2009.22.4.283
-
-
Abstract
PDF
- PURPOSE
To analyze the treatment of clinical results of the percutaneous Kirschner wire fixation of acute mallet fractures percutaneousely reduced by towel clip. MATERIALS AND METHODS: From August 2005 to April 2009, we evaluated nine fingers in eight patients, more than three months follow up. The type of injury was a axial loading in seven cases and direct blow in two. The average follow-up period was 10.1 months (range: 3~41 months). The indication of operative treatment was the presence of large bony fragment or the palmar subluxation of the distal phalnx. RESULTS: The range of motion was 3.7degrees (0~10degrees) in extension lag and 76.7degrees (60~90degrees) of flexion of the distal interphalangeal joint. CONCLUSION: The percutaneous Kirschner wire fixation of acute mallet fractures percutaneousely reduced by towel clip is one of the easy and simple method to stabilizing of bony mallet fracture.
-
Citations
Citations to this article as recorded by 
- Comparison of Surgical Outcomes of Percutaneous K-Wire Fixation in Bony Mallet Fingers with Use of Towel Clip versus 18-Gauge Needle
Ho-Seung Jeon, Chan-Sam Moon, Seo-Goo Kang, Kyeong-Seop Song, Uk-Hyun Choi Journal of the Korean Society for Surgery of the Hand.2013; 18(1): 1. CrossRef
-
144
View
-
0
Download
-
1
Crossref
|