-
New Wiring Method for Lesser Trochanter Fixation in Unstable Intertrochanteric Fractures: Technical Note
-
Joong Myung Lee, Jeong Hee Lee, Churl Woo Lee, Hyun Min Kim
-
J Korean Fract Soc 2005;18(2):209-212. Published online April 30, 2005
-
DOI: https://doi.org/10.12671/jkfs.2005.18.2.209
-
-
Abstract
PDF
- In unstable femoral trochanteric fracture, we usually used transversing K-wires through the lesser trochanter to achieve an anatomical reduction, and using sliding hip screws. However, in patients with comminuted lesser trochanter or osteoporosis, an intrusion of the wire into the lesser trochanter and/or iatrogenic intertrochanteric fractures were often resulted. Those who were not familiar with a technique of puncturing two holes through the lesser trochanter might have had to face some difficulties. In order to overcome aforementioned drawbacks, the authors had quite satisfactory results by employing the method of passing each of two wires above and below the iliopsoas muscle, and they were twisted posteriorly and then anteriorly; and finally they were pulled together posteriorly. Through this technique, both firm fixation of the lesser trochanter and more stable bony union were obtained.
-
Citations
Citations to this article as recorded by 
- The lesser trochanter “Sling fixation technique” in proximal intramedullary nailing of unstable intertrochanteric fractures: A polymer-based cerclage wiring
Marco Villano, Matteo Innocenti, Roberto Civinini, Christian Carulli, Alessandro Civinini, Zyad Ayman Taha, Andrea Cozzi Lepri Journal of Orthopaedics.2022; 34: 94. CrossRef - Unstable Intertrochanteric Fracture: Do We Know Everything? A Review
Balaji Zacharia, Harshitha Hayavadana Udupa SN Comprehensive Clinical Medicine.2022;[Epub] CrossRef - When to Reduce and Fix Displaced Lesser Trochanter in Treatment of Trochanteric Fracture: A Systematic Review
Ao-Lei Yang, Wei Mao, Jun-Guo Wu, Yi-Qun He, Hao-Fei Ni, Hai-Long Li, You-Hai Dong Frontiers in Surgery.2022;[Epub] CrossRef - Medial wall fragment involving large posterior cortex in pertrochanteric femur fractures: a notable preoperative risk factor for implant failure
Pengfei Li, Yang Lv, Fang Zhou, Yun Tian, Hongquan Ji, Zhishan Zhang, Yan Guo, Zhongwei Yang, Guojin Hou Injury.2020; 51(3): 683. CrossRef - In response
David J. Ciufo, John P. Ketz Journal of Orthopaedic Trauma.2018; 32(9): e382. CrossRef - Three-Dimensional Computed Tomography Reduced Fixation Failure of Intramedullary Nailing for Unstable Type of Intertrochanteric Fracture
Wei-Yu Li, Kai-Cheng Lin Journal of Orthopaedic Trauma.2018; 32(9): e381. CrossRef - Wiring Techniques for the Fixation of Trochanteric Fragments during Bipolar Hemiarthroplasty for Femoral Intertrochanteric Fracture: Clinical Study and Technical Note
Joong-Myung Lee, Yongsuk Cho, Junhyun Kim, Dong-Won Kim Hip & Pelvis.2017; 29(1): 44. CrossRef - Wiring technique for lesser trochanter fixation in proximal IM nailing of unstable intertrochanteric fractures: A modified candy-package wiring technique
Gyeong Min Kim, Kwang Woo Nam, Kyu-Bum Seo, Chaemoon Lim, Jiyun Kim, Yong-Geun Park Injury.2017; 48(2): 406. CrossRef - Bipolar Hemiarthroplasty with Cementless Femoral Stem for Unstable Intertrochanteric Fractures
Joong-Myung Lee, Hee-Tae Nam, Sang-Hun Lee Journal of the Korean Orthopaedic Association.2012; 47(2): 79. CrossRef
-
134
View
-
1
Download
-
9
Crossref
|