Skip Navigation
Skip to contents

J Musculoskelet Trauma : Journal of Musculoskeletal Trauma

OPEN ACCESS

Author index

Page Path
HOME > Browse articles > Author index
Search
Jae Cheon Sim 9 Articles
Concurrent Posterolateral Corner Injury Associated with a Schatzker Type 2 Tibial Plateau Fracture: A Case Report
Jae Cheon Sim, Choong Won Jung, Tae Seok Nam
J Korean Fract Soc 2020;33(1):27-31.   Published online January 31, 2020
DOI: https://doi.org/10.12671/jkfs.2020.33.1.27
AbstractAbstract PDF
Isolated posterolateral corner (PLC) injury associated with a Schatzker type 2 fracture is a very rare combination of injuries. A male who was driving a motor vehicle was injured after a collision accident. The plain radiographs and computed tomography scans of the knee showed a Schatzker type 2 fracture of the tibial plateau, mostly in the anterolateral portion of tibial plateau, and an avulsion fragment on the fibular tip. Magnetic resonance imaging showed no injury to cruciate ligaments, medial collateral ligament, or any meniscal injury. We performed an open reduction operation and internal fixation for treating the fracture. Six months later, he complained of instability. At 11 months later after initial operation, we performed the second operation for stabilizing the PLC. We present here a rare case of an isolated PLC injury associated with a Schatzker type 2 fracture. We discuss the mechanism of injury and review similar cases.
  • 156 View
  • 0 Download
Close layer
The Different Treatment Methods for Segmental Fractures of the Clavicle: Cases Report
Sung Sik Ha, Ki Do Hong, Jae Cheon Sim, Yi Rak Seo, Tae Seok Nam
J Korean Fract Soc 2017;30(3):151-155.   Published online July 31, 2017
DOI: https://doi.org/10.12671/jkfs.2017.30.3.151
AbstractAbstract PDF
Segmental fractures of the clavicle are very rare. Therefore, to date, there has not been a clear, standardized method of management of segmental clavicle fractures. Herein, two patients with a segmental fracture are described: One patient was treated conservatively, while another patient was treated operatively. Both patients showed excellent results. We discuss the various management options with a literature review.

Citations

Citations to this article as recorded by  
  • Fratura segmentar da clavícula em paciente politraumatizado: Relato de caso
    Carlos A. Sánchez, Pablo J. Coronel, Luisa F. García, Juan S. Afanador, Raúl Gonzalez
    Revista Brasileira de Ortopedia.2024; 59(01): e139.     CrossRef
  • 120 View
  • 0 Download
  • 1 Crossref
Close layer
Treatment of Fractures of the Distal Radius Using Variable-Angle Volar Locking Plate
Jae Cheon Sim, Sung Sik Ha, Ki Do Hong, Tae Ho Kim, Min Chul Sung
J Korean Fract Soc 2015;28(1):46-52.   Published online January 31, 2015
DOI: https://doi.org/10.12671/jkfs.2015.28.1.46
AbstractAbstract PDF
PURPOSE
The purpose of this study is to evaluate outcome of variable-angle volar locking plate for treatment of distal radius fractures.
MATERIALS AND METHODS
We retrospectively analyzed the results in 45 cases treated by variable-angle volar locking plate. We evaluated the clinical results according to the Mayo wrist performance scoring system and radiographic results.
RESULTS
All cases had bony union. The mean Mayo wrist performance scoring system was 84.8. Between preoperative and immediate postoperative radiographic measurement, the mean radial length improved from 8.4 to 11.8 mm, radial inclination from 14.2degrees to 22.4degrees, volar tilt from -4.5degrees to 9.6degrees, and intraarticular step-off from 1.8 to 0.3 mm (p<0.05). Between immediate postoperative and latest follow-up radiographic measurements, the mean loss of radial length measured 0.8 mm, radial inclination 0.4degrees, and volar tilt 0.9degrees (p>0.05). All cases showed bone union with no evidence of malunion, nonunion, or metal failure.
CONCLUSION
Treatment of distal radius fractures using variable angle volar locking plate showed satisfactory outcomes. It is a good option to obtain stable fixation without significant loss of reduction.
  • 66 View
  • 0 Download
Close layer
Treatment of Olecranon Fractures with Proximal Ulna Comminution Using Locking Compression Plates
Ki Do Hong, Tae Ho Kim, Jae Cheon Sim, Sung Sik Ha, Min Chul Sung, Jong Hyun Jeon
J Korean Fract Soc 2015;28(1):59-64.   Published online January 31, 2015
DOI: https://doi.org/10.12671/jkfs.2015.28.1.59
AbstractAbstract PDF
PURPOSE
The purpose of this study is to evaluate the clinical results of locking compression plate (LCP) fixation for olecranon fractures with proximal ulna comminution.
MATERIALS AND METHODS
We review 10 cases of olecranon fractures with proximal ulna comminution treated with LCPs from August 2011 to August 2013. Follow-up period was from 12 months to 18 months. Mean age was 63.1 years (35-84 years). According to the Mayo classification, there were eight type IIB, and two type IIIB fractures. We used Mayo classification. Clinical evaluation was performed based on radiographic union of olecranon and measurements of range of motion at last follow-up. Disability of the arm, shoulder and hand (DASH) score and Mayo elbow performance score (MEPS) were used for evaluation of functional recovery.
RESULTS
All patients had bone union. According to the MEPS, nine of ten patients had a good or excellent outcome. The mean DASH score was 18.6. All cases started postoperative range of motion (ROM) within 14 days. Elbow ROM was more than 110degrees in all cases except one. Mean radiological bony union time was 4.2 months (2.5-6.0 months) postoperatively. Complication was hardware irritation in three patients.
CONCLUSION
Internal fixation using LCP for olecranon fractures with proximal ulna comminution can be a good treatment option which obtains good clinical results and enables early ROM.
  • 80 View
  • 0 Download
Close layer
Comparative Study of Intertrochanteric Fracture Treated with the Proximal Femoral Nail Anti-Rotation and the Third Generation of Gamma Nail
Jae Cheon Sim, Tae Ho Kim, Ki Do Hong, Sung Sik Ha, Jong Seong Lee
J Korean Fract Soc 2013;26(1):37-43.   Published online January 31, 2013
DOI: https://doi.org/10.12671/jkfs.2013.26.1.37
AbstractAbstract PDF
PURPOSE
To compare the result between the third generation gamma nail (gamma 3 nail) and proximal femoral nail anti-rotation (PFNA) in the treatment of unstable intertrochanteric fractures.
MATERIALS AND METHODS
Between March 2009 and June 2011, 47 consecutive patients with unstable intertrochanteric femoral fractures were treated with gamma 3 nail or PFNA. We reviewed 24 cases of gamma 3 nail and 23 cases of PFNA. Retrospectively, we evaluated the mean operation time, amount of bleeding, average union period, reduction status, change of neck shaft angle, Tip-apex distance, Cleveland index, sliding of lag screw and complication on set of telephone interview and outpatient. We also evaluated the postoperative capability of function and mobility, using 'Modified Koval index'.
RESULTS
There were no significant differences between the groups, which were treated with gamma 3 nail and PFNA. In addition, they did not show statistical difference. We experienced 2 cases of complication (gamma 3 nail 1 case, PFNA 1 case), which were cut-out of the femoral head.
CONCLUSION
The gamma 3 nail and PFNA were seen with good results in the treatment of unstable intertrochanteric fracture.

Citations

Citations to this article as recorded by  
  • Comparative analysis of operation time and intraoperative fluoroscopy time in intramedullary and extramedullary fixation of trochanteric fractures
    Milan Mitkovic, Sasa Milenkovic, Ivan Micic, Predrag Stojiljkovic, Igor Kostic, Milorad Mitkovic
    Vojnosanitetski pregled.2022; 79(2): 177.     CrossRef
  • Does the Helical Blade Lead to Higher Rates of Fixation Failure as Compared to Lag Screw in the Cephalomedullary Nailing Treatment of Hip Fractures? A Systematic Review and Meta-Analysis
    Chul-Ho Kim, Han Soul Kim, Yong-Chan Kim, Dou Hyun Moon
    Journal of Orthopaedic Trauma.2021; 35(8): 401.     CrossRef
  • The Curative Effect Comparison Between Prolonged Third Generation of Gamma Nail and Prolonged Dynamic Hip Screw Internal Fixation in Treating Femoral Intertrochanteric Fracture and the Effect on Infection
    Wenye He, Wei Zhang
    Cell Biochemistry and Biophysics.2015; 71(2): 695.     CrossRef
  • Accuracy of the Lesser Trochanter for Guiding Lag Screw Insertion in Hip Fracture Management
    Jianlin Xiao, Zhongli Gao, Yanguo Qin, Xuezhou Li, Ao Wang, Lanyu Zhu, Jincheng Wang
    Orthopedics.2014;[Epub]     CrossRef
  • 103 View
  • 0 Download
  • 4 Crossref
Close layer
Lateral Plate Fixation of Distal Tibial Metaphyseal Fracture Using Minimally Invasive Plate Osteosynthesis Technique
Ki Do Hong, Sung Sik Ha, Nam Sik Chung, Jae Cheon Sim, Sang Cheon Ahn
J Korean Fract Soc 2006;19(1):24-28.   Published online January 31, 2006
DOI: https://doi.org/10.12671/jkfs.2006.19.1.24
AbstractAbstract
PURPOSE
To evaluate the efficiency of lateral plate fixation using minimally invasive plate osteosynthesis (MIPO) technique as a treatment of distal tibial metaphyseal fracture.
MATERIALS AND METHODS
Among the patient who were treated from March, 2002 to September, 2004, the cases of twenty patients with distal tibial metaphyseal fracture treated by lateral plate fixation using MIPO technique who were able to be followed up for at least one-year period were reviewed in this study. According to AO/OTA classification, five were type A1, twelve cases were type A2 and other three cases were type A3, and among them two cases were open fracture type I according to the Gustillo-Anderson classification. Radiologic studies and clinical assessment described by Daniel et al and complication following the treatment were evaluated.
RESULTS
At a mean of 16.4 weeks (range 11 to 23), all fractures united without secondary procedures. According to clinical assessment, all cases had good and excellent result, and there were no complications.
CONCLUSION
The lateral plate fixation using MIPO technique of distal tibial metaphyseal fracture is an efficient method of treatment with high functional recovery rate which minimize soft tissue damage, decreases the risk of infection and incidence of nonunion at the same time as the classic MIPO technique does, and it is a useful alternative method when there is a anteromedial soft tissue damage.

Citations

Citations to this article as recorded by  
  • Minimally Invasive Plate Osteosynthesis for Fractures of Distal Tibia
    Tae Hun Kim, So Hak Chung
    Kosin Medical Journal.2014; 29(1): 23.     CrossRef
  • Staged Protocol in Treatment of Open Distal Tibia Fracture: Using Lateral MIPO
    Oog Jin Sohn, Dong Hwa Kang
    Clinics in Orthopedic Surgery.2011; 3(1): 69.     CrossRef
  • Minimally Invasive Percutaneous Plate Osteosynthesis Using a Lateral Plate in Distal Tibial Fracture
    Oog Jin Shon, Dae Sung Kim
    Journal of the Korean Fracture Society.2010; 23(1): 42.     CrossRef
  • 115 View
  • 0 Download
  • 3 Crossref
Close layer
Treatment of Fractures of the Distal Radius using Locking Compression Plate
Jae Cheon Sim, Nam Sik Chung, Ki Do Hong, Sung Sik Ha, Ji Hoon Kang
J Korean Fract Soc 2005;18(2):100-104.   Published online April 30, 2005
DOI: https://doi.org/10.12671/jkfs.2005.18.2.100
AbstractAbstract PDF
PURPOSE
To evaluate the usefulness of locking compression plate (LCP) and volar plating through anterior approach for distal radius fracture.
MATERIALS AND METHODS
We retrospectively analysed that 15 distal radius fracture, which would not be reduced by closed reduction or too comminuated to maintain reduction or articular surface inconguency, were treated by open reduction through anterior approach and volar plating using LCP. The results were evaluated by preoperative and postoperative radiographs. Functional results were analysed using the Modified Mayo Wrist Scoring System.
RESULTS
All cases achieved anatomical articular surface reduction postoperatively. In terms of radiologic analysis, mean radial length (9.0 mm vs. 11.8 mm), radial inclination (14.7degrees vs. 20.9degrees ), volar tilt (-6.3degrees vs. 8.3degrees ) and articular step-off (1.4 mm vs. 0.3 mm) were improved. The average Modified Wrist Score was 89. Nonunion or malunion was not occurred.
CONCLUSION
Open reduction through anterior approach and volar plating using LCP is a useful method that provides excellent results with few complications in the treatment of fracture of the distal radius.

Citations

Citations to this article as recorded by  
  • Periprosthetic Fracture after Locked Plating in the Osteoporotic Long Bone Fracture
    Ki-Chul Park, Hong-Sik Kim, Jeong-Han Oh
    Journal of the Korean Orthopaedic Association.2012; 47(3): 222.     CrossRef
  • 2.4 mm Volar Locking Compression Plate for Treatment of Unstable Distal Radius Fractures
    Sung-Jin Kim, Chul-Hyun Cho
    Journal of the Korean Fracture Society.2011; 24(2): 151.     CrossRef
  • Treatment of Femur Supracondylar Fracture with Locking Compression Plate
    Seong Ho Bae, Seung Han Cha, Jeung Tak Suh
    Journal of the Korean Fracture Society.2010; 23(3): 282.     CrossRef
  • Comparison of Outcomes for Unstable Distal Radius Intraarticular Fractures - T-locking Compression Plate versus External Fixator -
    Chul-Hyun Cho, Su-Won Jung, Sung-Won Sohn, Chul Hyung Kang, Ki-Cheor Bae, Kyung-Jae Lee
    Journal of the Korean Fracture Society.2008; 21(1): 51.     CrossRef
  • Basic Principle of the Locking Compression Plate
    Keun Bae Lee
    Journal of the Korean Fracture Society.2008; 21(3): 261.     CrossRef
  • Volar T-Locking Compression Plate for Treatment of Unstable Distal Radius Fractures
    Chul Hyun Cho, Ki Choer Bae, Doo Hyun Kwon
    Journal of the Korean Fracture Society.2008; 21(3): 220.     CrossRef
  • 139 View
  • 0 Download
  • 6 Crossref
Close layer
Intramedullary Fixation of Clavicle Fracture Percutaneously Reduced By Towel Clip
Ki Do Hong, Sung Sik Ha, Nam Sik Chung, Jae Cheon Sim, Gyoung Ho Kim
J Korean Fract Soc 2004;17(4):328-332.   Published online October 31, 2004
DOI: https://doi.org/10.12671/jkfs.2004.17.4.328
AbstractAbstract PDF
PURPOSE
To investigate the utility of surgical treatment of clavicle shaft fracture using a percutaneous towel clip reduction and intramedullary fixation.
MATERIALS AND METHODS
This study was conducted for total 16 cases of patients who had no neurovascular injury and a few comminuted bone fragment among patients with clavicle shaft fracture from January 2002 to July 2003. The method of operation was percutaneous towel clip reduction and intramedullary fixation. The clinical and radiological results were evaluated.
RESULTS
Radiologically, 15 cases showed bone unions and the average time was 9.1 weeks. According to Kang's criteria clinically, there were 14 cases which were more than an excellence. One case substituted open reduction and nailing fixation due to a medial migration of K-wire and re- displacement of fracture even in 1 week. However, there wasn't any other major complication.
CONCLUSION
Due to its having no additional injury to soft tissues, no scar formations, and its short operation time, percutaneous towel clip reduction and intramedullary fixation will be very useful as one of the treatments of clavicular shaft fracture if it follows correct surgical indications.

Citations

Citations to this article as recorded by  
  • Comparison of Results in Two Operative Treatments for Clavicle Shaft Fractures in Adult: Comparison of Results between Open Reduction and Internal Fixation with the Plate and Percutaneous Reduction by Towel Clip and Intramedullary Fixation with Steinmann
    Sung-Sik Ha, Jae-Chun Sim, Ki-Do Hong, Jae-Young Kim, Jung-Ho Kang, Kwang-Hee Park
    Journal of the Korean Fracture Society.2007; 20(3): 233.     CrossRef
  • 108 View
  • 0 Download
  • 1 Crossref
Close layer
Nancy Nail Fixation for Femur Shaft Fracture in Children
Ki Do Hong, Sung Sik Ha, Nam Sik Chung, Jae Cheon Sim, Jae Young Kim
J Korean Soc Fract 2003;16(4):592-599.   Published online October 31, 2003
DOI: https://doi.org/10.12671/jksf.2003.16.4.592
AbstractAbstract PDF
PURPOSE
To investigate, the radiologically, the duration of bone union, angular formation, leg length discrepancy, other complications and mean hospital stay after Nancy nail fixation has been performed in children with femoral shaft fracture, and also to inquire into the clinical validity of such procedure. MATERIAL AND METHOD: Included in this study were 12 patients who had been treated with the Nancy nail fixation for the femoral shaft fracture and then followed up for a year or more. The age distribution ranged from 4 to 12 years with mean age 7.2 years. After the fracture was reduced under an imaging intensifier, 2 or 3 Nancy nails were pinned onto the medial and lateral femur distally.
RESULTS
The average duration for complete union was 9.9 weeks. Any angular formation over 5 degrees was notfound. Leg length discrepancy ranged from 2 mm shortening to 12 mm overgrowth with a mean value of 2.8 cm. In one case, with overgrowth over 10 mm or more, there was no gait disturbance. In all cases, There was neither infection, delayed union, nor any motion disturbance. A nail was moved distally in one case and skin irritation was evident in another case. The mean hospital stay was 17.3 days.
CONCLUSION
Nancy nail fixation in pediatric femoral shaft fracture relatively has less complications and is a safe surgical procedure. In addition, it helps in reducing hospital stay.

Citations

Citations to this article as recorded by  
  • Comparison of Flexible Intramedullary Nailing with External Fixation in Pediatric Femoral Shaft Fractures
    Do-Young Kim, Sung-Ryong Shin, Un-Seob Jeong, Yong-Wook Park, Sang-Soo Lee, Keun-Min Park
    The Journal of the Korean Orthopaedic Association.2008; 43(1): 30.     CrossRef
  • 155 View
  • 0 Download
  • 1 Crossref
Close layer

J Musculoskelet Trauma : Journal of Musculoskeletal Trauma
Close layer
TOP