Skip Navigation
Skip to contents

J Musculoskelet Trauma : Journal of Musculoskeletal Trauma

OPEN ACCESS

Author index

Page Path
HOME > Browse articles > Author index
Search
Hong Kee Yoon 2 Articles
T Plate Fixation for Unstable Fracture of Distal Clavicle
Ho Jung Kang, Kwan Kyu Park, Hong Kee Yoon, Hyung Keun Song, Soo Bong Hahn
J Korean Fract Soc 2006;19(3):329-334.   Published online July 31, 2006
DOI: https://doi.org/10.12671/jkfs.2006.19.3.329
AbstractAbstract
PURPOSE
To review clinical and radiological results after open reduction and internal fixation with T plate for unstable distal clavicle fractures.
MATERIALS AND METHODS
From July. 1999 to December 2002, nine patients with distal clavicle Neer type II fractures were treated by open reduction and internal fixation with T plate. The bony union was confirmed by plain radiography. The clinical results were analyzed according to the classification by Kona et al.
RESULTS
Average time to fracture union was 8 weeks in all cases. The functional results were as follows: excellent in 7 cases and good in 2 cases. Screw loosening occurred in one case, but bony union was achieved.
CONCLUSION
We recommend T plate fixation as another treatment method for unstable distal clavicle fractures.

Citations

Citations to this article as recorded by  
  • Usefulness of the Additional K-Wire Fixation and Suture for Reinforce the Treatment of Distal Clavicle Fracture Using Modified Tension Band Wiring
    Seung-Bum Chae, Chang-Hyuk Choi, Dong-Young Kim
    Journal of the Korean Fracture Society.2016; 29(2): 107.     CrossRef
  • Treatment of Distal Clavicle Fracture Using Hook Plate
    Su-Han Ahn, Hyeong-Jo Yoon, Kwang-Yeol Kim, Hyung-Chun Kim, In-Yeol Kim
    Journal of the Korean Fracture Society.2011; 24(1): 48.     CrossRef
  • The Surgical Outcomes of Clavicle Lateral End Fractures Fixed with the Oblique T Locking Compession Plate
    Seung-Oh Nam, Young-Soo Byun, Dong-Ju Shin, Jung-Hoon Shin, Chung-Yeol Lee, Tae-Gyun Kim
    Journal of the Korean Fracture Society.2011; 24(1): 41.     CrossRef
  • Results of Hook Plate Fixation of Unstable Distal Clavicle Fractures
    Hoon-Sang Sohn, Byung Chul Jo
    Journal of the Korean Fracture Society.2011; 24(4): 335.     CrossRef
  • Modified Spring Plate for Treatment of Unstable Distal Clavicle Fractures
    Sang-Myung Lee, Il-Jung Park, Hyung-Min Kim, Jae-Chul Park, Sung-Gil Cho, Yoon-Chung Kim, Seung-Koo Rhee
    Journal of the Korean Fracture Society.2010; 23(1): 64.     CrossRef
  • Double Tension Band Wire Fixation for Unstable Fracture of the Distal Clavicle
    Kyeong-Seop Song, Hyung-Gyu Kim, Byeong-Mun Park, Jong-Min Kim, Sung-Hoon Jung, Bong-Seok Yang
    Journal of the Korean Fracture Society.2009; 22(1): 24.     CrossRef
  • 120 View
  • 0 Download
  • 6 Crossref
Close layer
Cannulated Screw Fixation for 4 Part Fractures of the Neck of Humerus
Ho Jung Kang, Doo Hyung Lee, Hong Kee Yoon, Soo Bong Hahn
J Korean Fract Soc 2005;18(4):432-436.   Published online October 31, 2005
DOI: https://doi.org/10.12671/jkfs.2005.18.4.432
AbstractAbstract PDF
PURPOSE
To analyze radiological and functional results after open reduction and internal fixation for fractures of the neck of humerus (4-part) using cannulated screws. MATERIAL AND METHODS: Between January 1997 and April 2004, 11 patients with neck of humerus fracture (4-part) were treated operatively by open reduction and internal fixation with cannulated screws. Two surgical approaches (deltopectoral for 9 cases and deltoid splitting for 2 cases) were used. The mean age was 36 years old and the mean duration of follow-up was 56 months. ASES (American Shoulder and Elbow Surgeons) score was checked to evaluate the function in shoulder joint. We used 2 cannulated screws in 2 cases, 3~4 screws in 6 cases and over 5 screws in 3 cases for fixation. In 2 cases, K-wires were used additionally and autoiliac bone graft was done in 1 cases which had poor bone mass.
RESULTS
All cases got bony union at 5.6 months on average. In functional assessment of shoulder, eight patients got excellent, one got good points. There were complications including shoulder stiffness in 2 cases, avascular necrosis of humeral head in 1 case and subacromial impingement syndrome in 1 case.
CONCLUSION
Internal fixation using cannulated screws for fractures of humerus neck (4 part) showed good bony union and functional results in patients under 50 years old who had average bone quality.

Citations

Citations to this article as recorded by  
  • The Surgical Outcomes for Isolated Greater Tuberosity Fracture of Proximal Humerus
    Eun-Sun Moon, Myung-Sun Kim, Young-Jin Kim
    Journal of the Korean Fracture Society.2007; 20(3): 239.     CrossRef
  • 110 View
  • 0 Download
  • 1 Crossref
Close layer

J Musculoskelet Trauma : Journal of Musculoskeletal Trauma
Close layer
TOP