PURPOSE
A technique of cerclage wire fixation in comminuted fracture of the clavicle shaft is thought to interfere the fracture healing, so authors studied radiographically and clinically about the cases of cerclage wiring of the fracture fragments with the plate and screws fixation in the comminuted fracture of the shaft of the clavicle.
MATERIALS AND METHODS
According to following inclusion criteria, total 18 patients (male: 15, female: 3) were investigated; Patients who visited hospital due to clavicle shaft comminuted fracture from February 2005 to April 2009, who underwent surgery utilizing more than 2 cerclage wire fixation for the fragments when open reduction and plate fixation were operated and who could be follow-up over one year. The duration for fracture union, functional outcome and complications were investigated retrospectively.
RESULTS
Radiological bone union was accomplished in average 13.3 weeks (12~16 weeks) and there was no complication such as nonunion, delayed union or infection. Range of motion of ipsilateral shoulder joint was recovered in all patients except one at the final follow-up.
CONCLUSION
The clinical and radiographical results of the plate and screws fixation with cerclage wiring of the fragments in comminuted clavicle shaft fracture showed that the cerclage wiring does not interfere the fracture healing, so authors think that this method is a good alternative operation if it is performed carefully to minimize soft tissue dissection.

Citations

Citations to this article as recorded by  
  • Surgical Management of Comminuted Midshaft Clavicle Fractures Using Reconstruction Plate and Circumferential Wiring: Does the Circumferential Wiring Interfere with the Bone Union?
    Kyung-Tae Kim, Chung-Shik Shin, Young-Chul Park, Dong-hyun Kim, Min-Woo Kim
    Journal of the Korean Orthopaedic Association.2021; 56(3): 245.     CrossRef
  • Supplementary Technique for Unstable Clavicle Shaft Fractures: Interfragmentary Wiring and Temporary Axial K-Wire Pinning
    Jinmyoung Dan, Byung-Kook Kim, Ho-Jae Lee, Tae-Ho Kim, Young-Gun Kim
    Clinics in Orthopedic Surgery.2018; 10(2): 142.     CrossRef
  • Use of Composite Wiring on Surgical Treatments of Clavicle Shaft Fractures
    Kyung Chul Kim, In Hyeok Rhyou, Ji Ho Lee, Kee Baek Ahn, Sung Chul Moon
    Journal of the Korean Fracture Society.2016; 29(3): 185.     CrossRef
  • TO EVALUATE THE SURGICAL OUTCOME OF NON-UNION CLAVICLE USING PLATE AND SLIVERS OF AUTOLOGOUS ILIAC CREST CORTICOCANCELLOUS BONE GRAFT
    Mohammed Tauheed, Shashi Kumar Yalagach, Vivek Purushothaman, Anwar Shareef Kunnath K
    Journal of Evidence Based Medicine and Healthcare.2016; 3(25): 1121.     CrossRef
  • Anatomical Reduction of All Fracture Fragments and Fixation Using Inter-Fragmentary Screw and Plate in Comminuted and Displaced Clavicle Mid-Shaft Fracture
    Kyoung Hwan Koh, Min Soo Shon, Seung Won Lee, Jong Ho Kim, Jae Chul Yoo
    Journal of the Korean Fracture Society.2012; 25(4): 300.     CrossRef
  • 198 View
  • 0 Download
  • 5 Crossref
Close layer
Interlocking Intramedullary Nailing of Forearm Shaft Fractures in Adults
Sanglim Lee, Hee Sung Lee, Yerl Bo Sung, Jae Kwang Yum
J Korean Fract Soc 2009;22(1):30-38.   Published online January 31, 2009
DOI: https://doi.org/10.12671/jkfs.2009.22.1.30
AbstractAbstract PDF
PURPOSE
To evaluate the usefulness of interlocking intramedullary nailing for operative treatment of forearm shaft fractures in adults.
MATERIALS AND METHODS
Thirteen forearm shaft fractures in 12 patients were fixated with 13 Acumed forearm intramedullary rods (ulna: 8, radius: 5). The average age was 36.7 years and mean follow-up period was 15.2 months. The union time was measured when there was no tenderness over the fracture site and the bridging callus was evident in at least two sides of the cortex. The range of motion of the joint and the rotation of the forearm was measured and the functional results were evaluated with Grace and Eversmann's rating system.
RESULTS
Radiologic union was observed at 11.8 weeks postoperatively in 11 cases out of 13. No limitation of motion was observed. Nine had excellent or good functional results. In one Galeazzi fracture, radial shaft became displaced after nailing and should be re-stabilized with plate. Proximal interlocking screws were improperly inserted in one ulnar nail. Implants were removed in 7 cases. Removal guide screw was broken while removing the intramedullary nail in one case of ulnar shaft fracture.
CONCLUSION
Interlocking intramedullay nailing might be a treatment option for the middle 1/3 shaft fractures of the adult forearm bone with favorable results.

Citations

Citations to this article as recorded by  
  • Comparison of minimally invasive plate osteosynthesis (MIPO) and open reduction and internal fixation (ORIF) for the treatment of radial shaft fractures: a retrospective study
    Hyun-Tak Kang, Yang-Hoon Jo, Hong-Je Kang
    BMC Musculoskeletal Disorders.2025;[Epub]     CrossRef
  • Distal blocking screw augmentation in ulnar intramedullary nail fixation of adult forearm diaphyseal fractures
    Yong Woo Kim, Sang Ki Lee, Young Sun An
    Journal of Orthopaedic Surgery.2024;[Epub]     CrossRef
  • Comparison of Bending Strength among Plate, Steinmann Pin, and Headless Compression Screw Fixations for Proximal Ulnar Shaft Fracture in Sawbones
    Jinyoung Han, Jin Rok Oh, Jaewoong Um
    Archives of Hand and Microsurgery.2020; 25(4): 267.     CrossRef
  • 177 View
  • 1 Download
  • 3 Crossref
Close layer

J Musculoskelet Trauma : Journal of Musculoskeletal Trauma
Close layer
TOP